cc/td/doc/product/lan/cat6000
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Release Notes for Cisco IOS Release 12.2SX on the Supervisor Engine 720, Supervisor Engine 32, and Supervisor Engine 2

Contents

Chronological List of Releases

Hierarchical List of Releases

Supported Hardware

Supervisor Engines

Policy Feature Cards

Distributed and Centralized Forwarding Cards

Switch Fabric Modules

Transceivers

10-Gigabit Ethernet Switching Modules

Gigabit Ethernet Switching Modules

Power over Ethernet Daughtercards

10/100/1000 Ethernet Switching Modules

Fast Ethernet Switching Modules

Ethernet/Fast Ethernet (10/100) Switching Modules

Ethernet Switching Modules

Optical Services Modules (OSMs)

Shared Port Adapter (SPA) Interface Processors (SIPs)

Shared Port Adapters (SPAs)

Services SPA Carrier (SSC)

Services SPAs

FlexWAN and Enhanced FlexWAN Modules

FlexWAN and Enhanced FlexWAN Module Port Adapters

Service Modules

Fan Trays

Power Supplies

Chassis

Unsupported Hardware

FPD Image Packages

FPD-Image Dependant Modules

FPD Image Package Contents

FPD Upgrades

Cisco IOS Software Modularity

Cisco IOS Software Modularity Images

Cisco IOS Software Modularity Documentation

Cisco IOS Software Modularity Unsupported Features

Feature Sets

Feature Set Guidelines and Restrictions

Feature Set Descriptions

Feature Sets in Release 12.2(18)SXF

Feature Sets in Release 12.2(18)SXE and Rebuilds

Feature Sets in Release 12.2(18)SXD and Rebuilds

Feature Sets in Release 12.2(17d)SXB and Rebuilds

Feature Sets in Release 12.2(17b)SXA and Rebuilds (Deferred)

Feature Sets in Release 12.2(17a)SX and Rebuilds (Deferred)

Feature Sets in Release 12.2(14)SX and Rebuilds (Deferred)

New Features

New Features in Release 12.2(18)SXF5

New Features in Release 12.2(18)SXF4

New Features in Release 12.2(18)SXF3

New Features in Release 12.2(18)SXF2

New Features in Release 12.2(18)SXF1

New Features in Release 12.2(18)SXF

New Features in Release 12.2(18)SXE6

New Features in Release 12.2(18)SXE5

New Features in Release 12.2(18)SXE4

New Features in Release 12.2(18)SXE3

New Features in Release 12.2(18)SXE2

New Features in Release 12.2(18)SXE1

New Features in Release 12.2(18)SXE

New Features in Release 12.2(18)SXD7

New Features in Release 12.2(18)SXD6

New Features in Release 12.2(18)SXD5

New Features in Release 12.2(18)SXD4

New Features in Release 12.2(18)SXD3

New Features in Release 12.2(18)SXD2

New Features in Release 12.2(18)SXD1

New Features in Release 12.2(18)SXD

New Features in Release 12.2(17d)SXB11a

New Features in Release 12.2(17d)SXB11

New Features in Release 12.2(17d)SXB10

New Features in Release 12.2(17d)SXB9

New Features in Release 12.2(17d)SXB8

New Features in Release 12.2(17d)SXB7

New Features in Release 12.2(17d)SXB6

New Features in Release 12.2(17d)SXB5

New Features in Release 12.2(17d)SXB4

New Features in Release 12.2(17d)SXB3

New Features in Release 12.2(17d)SXB2

New Features in Release 12.2(17d)SXB1

New Features in Release 12.2(17d)SXB

New Features in Release 12.2(17b)SXA2

New Features in Release 12.2(17b)SXA

New Features in Release 12.2(17a)SX4

New Features in Release 12.2(17a)SX3

New Features in Release 12.2(17a)SX2

New Features in Release 12.2(17a)SX1

New Features in Release 12.2(17a)SX

New Features in Release 12.2(14)SX1

New Features in Release 12.2(14)SX

Software Features from Earlier Releases

Unsupported Features and Commands

Limitations and Restrictions

Restrictions Removed by the PFC3

General Limitations and Restrictions

FlexWAN Limitations and Restrictions

OSM Limitations and Restrictions

Service Module Limitations and Restrictions

Caveats

Caveats in Release 12.2(18)SXF and Rebuilds

Caveats in Release 12.2(18)SXE and Rebuilds

Caveats in Release 12.2(18)SXD and Rebuilds

Caveats in Release 12.2(17d)SXB and Rebuilds

Caveats in Release 12.2(17b)SXA and Rebuilds

Caveats in Release 12.2(17a)SX and Rebuilds

Caveats in Release 12.2(14)SX and Rebuilds

Troubleshooting

System Troubleshooting

Module Troubleshooting

VLAN Troubleshooting

Spanning Tree Troubleshooting

Additional Troubleshooting Information

System Software Upgrade Instructions

Related Documentation

Release-Specific Documents

Platform-Specific Documents

Cisco Feature Navigator

Cisco IOS Software Documentation Set

Obtaining Documentation

Cisco.com

Product Documentation DVD

Ordering Documentation

Documentation Feedback

Cisco Product Security Overview

Reporting Security Problems in Cisco Products

Product Alerts and Field Notices

Obtaining Technical Assistance

Cisco Technical Support & Documentation Website

Submitting a Service Request

Definitions of Service Request Severity

Obtaining Additional Publications and Information


Release Notes for Cisco IOS Release 12.2SX on the Supervisor Engine 720, Supervisor Engine 32, and Supervisor Engine 2


July 10, 2006


NoteThis publication applies to these platforms:

CAT6000-SUP720/MSFC3

7600-SUP720/MSFC3

CAT6000-SUP32/MSFC2A (not supported in all releases)

7600-SUP32/MSFC2A (not supported in all releases)

CAT6000-SUP2/MSFC2 (not supported in all releases)

7600-SUP2/MSFC2 (not supported in all releases)

These release notes are for Cisco IOS Release 12.2SX on both the supervisor engine and the MSFC. If you are running the Catalyst operating system on the supervisor engine and Cisco IOS Release 12.2SX only on the MSFC, refer to this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/sw_8_1/ol_4563.htm


The most current release notes for 12.2SX on the supervisor engine and MSFC are available on Cisco.com at this URL:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/ol_4164.htm


Caution Cisco IOS running on the supervisor engine and the MSFC supports redundant configurations where the supervisor engines and MSFCs are identical. If they are not identical, one will boot first and become active and hold the other supervisor engine and MSFC in a reset condition.

Contents

This publication consists of these sections:

Chronological List of Releases

Hierarchical List of Releases

Supported Hardware

Unsupported Hardware

FPD Image Packages

Cisco IOS Software Modularity

Feature Sets

New Features

Unsupported Features and Commands

Limitations and Restrictions

Caveats

Troubleshooting

System Software Upgrade Instructions

Related Documentation

Obtaining Documentation

Documentation Feedback

Cisco Product Security Overview

Product Alerts and Field Notices

Obtaining Technical Assistance

Obtaining Additional Publications and Information

Chronological List of Releases


NoteSee the "Feature Sets" section for information about which releases are deferred.

See the "Hierarchical List of Releases" section for information about parent releases.


This is a chronological list of the 12.2SX releases:

10 Jul 2006—Release 12.2(18)SXF5

08 Jun 2006—Release 12.2(18)SXE6

17 Apr 2006—Release 12.2(17d)SXB11a

27 Mar 2006—Release 12.2(18)SXF4

16 Feb 2006—Release 12.2(18)SXF3

13 Feb 2006—Release 12.2(18)SXE5

20 Jan 2006—Release 12.2(18)SXF2

22 Dec 2005—Release 12.2(18)SXF1

15 Dec 2005—Release 12.2(18)SXD7

17 Nov 2005—Release 12.2(17d)SXB11

10 Oct 2005—Release 12.2(18)SXE4

12 Sep 2005—Release 12.2(18)SXF

22 Aug 2005—Release 12.2(18)SXE3

22 Aug 2005—Release 12.2(18)SXD6

16 Aug 2005—Release 12.2(17d)SXB10

21 Jul 2005—Release 12.2(17d)SXB9

23 Jun 2005—Release 12.2(18)SXE2

16 May 2005—Release 12.2(18)SXD5

02 May 2005—Release 12.2(17d)SXB8

18 Apr 2005—Release 12.2(18)SXE1

11 Apr 2005—Release 12.2(18)SXE

24 Mar 2005—Release 12.2(18)SXD4

01 Mar 2005—Release 12.2(17d)SXB7

21 Dec 2004—Release 12.2(17d)SXB6

13 Dec 2004—Release 12.2(18)SXD3

01 Nov 2004—Release 12.2(17d)SXB5

22 Oct 2004—Release 12.2(18)SXD2

30 Sep 2004—Release 12.2(18)SXD1

07 Sep 2004—Release 12.2(17d)SXB4

17 Aug 2004—Release 12.2(17d)SXB3

26 Jul 2004—Release 12.2(18)SXD

21 Jul 2004—Release 12.2(17d)SXB2

01 Jun 2004—Release 12.2(17d)SXB1

23 Apr 2004—Release 12.2(17a)SX4

22 Apr 2004—Release 12.2(17b)SXA2

05 Mar 2004—Release 12.2(17d)SXB

05 Mar 2004—Release 12.2(17a)SX3

29 Jan 2004—Release 12.2(17a)SX2

31 Dec 2003—Release 12.2(17b)SXA

30 Oct 2003—Release 12.2(17a)SX1

06 Oct 2003—Release 12.2(17a)SX

01 Jul 2003—Release 12.2(14)SX2 (MSFC3 only)

28 May 2003—Release 12.2(14)SX1

14 Apr 2003—Release 12.2(14)SX

Hierarchical List of Releases


Note See the "Feature Sets" section for information about which releases are deferred.


These releases support the hardware listed in the "Supported Hardware" section:

Release 12.2(18)SXF5:

Date of release: 10 Jul 2006

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Based on Release 12.2(18)SXF4

Release 12.2(18)SXF4:

Date of release: 27 Mar 2006

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Based on Release 12.2(18)SXF3

Release 12.2(18)SXF3:

Date of release: 16 Feb 2006

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Based on Release 12.2(18)SXF2

Release 12.2(18)SXF2:

Date of release: 20 Jan 2006

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Based on Release 12.2(18)SXF1, Release 12.2(18)SXE4, Release 12.2(18)SXD7, and Release 12.2(17d)SXB11

Release 12.2(18)SXF1:

Date of release: 22 Dec 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Based on Release 12.2(18)SXF

Release 12.2(18)SXF:

Date of release: 12 Sep 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Based on Release  12.2(18)SXE3, Release  12.2(18)SXD6, and Release  12.2(17d)SXB10

Release 12.2(18)SXE6:

Date of release: 08 Jun 2006

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXE5

Release 12.2(18)SXE5:

Date of release: 13 Feb 2006

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXE4

Release 12.2(18)SXE4:

Date of release: 10 Oct 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXE3

Release 12.2(18)SXE3:

Date of release: 22 Aug 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXE2

Release 12.2(18)SXE2:

Date of release: 23 Jun 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXE1

Release 12.2(18)SXE1:

Date of release: 18 Apr 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXE

Release 12.2(18)SXE:

Date of release: 11 Apr 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Based on Release 12.2(18)SXD4 and 12.2(17d)SXB7

Release 12.2(18)SXD7:

Date of release: 15 Dec 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXD6

Release 12.2(18)SXD6:

Date of release: 22 Aug 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXD5

Release 12.2(18)SXD5:

Date of release: 16 May 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXD4

Release 12.2(18)SXD4:

Date of release: 24 Mar 2005

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXD3

Release 12.2(18)SXD3:

Date of release: 13 Dec 2004

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXD2

Release 12.2(18)SXD2:

Date of release: 22 Oct 2004

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXD1

Release 12.2(18)SXD1:

Date of release: 30 Sep 2004

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Rebuild based on Release 12.2(18)SXD

Release 12.2(18)SXD:

Date of release: 26 Jul 2004

Parent in Release 12.2S: 12.2(18)S (not all features in Release 12.2(18)S are supported)

Based on Release 12.2(17d)SXB2


Note For information about Release 12.2(18)S, refer to these publications on Cisco.com:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122s/122snwft/release/122s18/index.htm


Release 12.2(17d)SXB11a:

Date of release: 17 Apr 2006

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Rebuild based on Release 12.2(17d)SXB11

Release 12.2(17d)SXB11:

Date of release: 17 Nov 2005

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Rebuild based on Release 12.2(17d)SXB10

Release 12.2(17d)SXB10:

Date of release: 16 Aug 2005

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Rebuild based on Release 12.2(17d)SXB9

Release 12.2(17d)SXB9:

Date of release: 21 Jul 2005

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Rebuild based on Release 12.2(17d)SXB8

Release 12.2(17d)SXB8:

Date of release: 24 Apr 2005

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17d)

Rebuild based on Release 12.2(17d)SXB7

Release 12.2(17d)SXB7:

Date of release: 01 Mar 2005

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17d)

Rebuild based on Release 12.2(17d)SXB6

Release 12.2(17d)SXB6:

Date of release: 21 Dec 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17d)

Rebuild based on Release 12.2(17d)SXB5

Release 12.2(17d)SXB5:

Date of release: 01 Nov 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17d)

Rebuild based on Release 12.2(17d)SXB4

Release 12.2(17d)SXB4:

Date of release: 07 Sep 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17d)

Rebuild based on Release 12.2(17d)SXB3

Release 12.2(17d)SXB3:

Date of release: 17 Aug 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17d)

Rebuild based on Release 12.2(17d)SXB2

Release 12.2(17d)SXB2:

Date of release: 21 Jul 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17d)

Rebuild based on Release 12.2(17d)SXB1

Release 12.2(17d)SXB1:

Date of release: 01 Jun 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17d)

Rebuild based on Release 12.2(17d)SXB and Release 12.2(17a)SX4

Release 12.2(17d)SXB:

Date of release: 05 Mar 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17d)

Based on Release 12.2(17b)SXA and Release 12.2(17a)SX3


Note For information about Release 12.2(17d), refer to these publications on Cisco.com:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/index.htm


Release 12.2(17b)SXA2 (deferred):

Date of release: 22 Apr 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17b)

Rebuild based on Release 12.2(17b)SXA.

Release 12.2(17b)SXA (deferred):

Date of release: 31 Dec 2003

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17b)

Based on Release 12.2(17a)SX1.


Note For information about Release 12.2(17b), refer to these publications on Cisco.com:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/index.htm


Release 12.2(17a)SX4 (deferred):

Date of release: 23 Apr 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17a)

Rebuild based on Release 12.2(17a)SX3

Release 12.2(17a)SX3 (deferred):

Date of release: 05 Mar 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17a)

Rebuild based on Release 12.2(17a)SX2

Release 12.2(17a)SX2 (deferred):

Date of release: 29 Jan 2004

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17a)

Rebuild based on Release 12.2(17a)SX1

Release 12.2(17a)SX1 (deferred):

Date of release: 30 Oct 2003

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17a)

Rebuild based on Release 12.2(17a)SX

Release 12.2(17a)SX (deferred):

Date of release: 06 Oct 2003

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Includes all resolved caveats from Release 12.2(17a)

Based on Release  12.2(14)SX1.


NoteFor information about Release 12.2(17a), refer to these publications on Cisco.com:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/index.htm

Release 12.2(14)SX2 (01 Jul 2003) only supports the MSFC3 and is for use with the Catalyst operating system on the Supervisor Engine 720. Release 12.2(14)SX2 has only MSFC3 images. Release 12.2(14)SX2 does not have any Supervisor Engine 720 images.


Release 12.2(14)SX1 (deferred):

Date of release: 28 May 2003

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)

Rebuild based on Release 12.2(14)SX

Release 12.2(14)SX (deferred):

Date of release: 14 Apr 2003

Parent in Release 12.2S: 12.2(14)S (not all features in Release 12.2(14)S are supported)


Note For information about Release 12.2(14)S, refer to these publications on Cisco.com:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122s/index.htm


This publication does not describe features that are available in Release 12.2, Release 12.2 T, Release 12.2 S, or other Release 12.2 early deployment releases.

For a list of the Release 12.2 caveats that apply to Release 12.2SX, see the "Caveats" section and refer to this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122relnt/xprn122/index.htm

For a list of the Release 12.2 S caveats that apply to Release 12.2SX, see the "Caveats" section and refer to this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122relnt/122srn.htm

For general product information about the Catalyst 6500 series switches, refer to the Catalyst 4000, 5000, and 6000 Family Software Product Bulletin (URL below). For general information about Release 12.2SX, refer to the Product Bulletin at these URLs:

http://www.cisco.com/warp/public/cc/pd/si/casi/ca6000/prodlit/

http://www.cisco.com/warp/public/732/releases/release122/122s/pbs/

Supported Hardware

These sections describe the hardware supported in Release 12.2SX:

Supervisor Engines

Policy Feature Cards

Distributed and Centralized Forwarding Cards

Switch Fabric Modules

Transceivers

10-Gigabit Ethernet Switching Modules

Gigabit Ethernet Switching Modules

Power over Ethernet Daughtercards

10/100/1000 Ethernet Switching Modules

Fast Ethernet Switching Modules

Ethernet/Fast Ethernet (10/100) Switching Modules

Ethernet Switching Modules

Optical Services Modules (OSMs)

Shared Port Adapter (SPA) Interface Processors (SIPs)

Shared Port Adapters (SPAs)

Services SPA Carrier (SSC)

Services SPAs

FlexWAN and Enhanced FlexWAN Modules

FlexWAN and Enhanced FlexWAN Module Port Adapters

Service Modules

Fan Trays

Power Supplies

Chassis


NoteUse the values in the "Power Required" column to determine the exact power requirements for your configuration to ensure that you are within the power budget.

Daughtercard power is shown separately.

Enter the show power command to display current system power usage.


Supervisor Engines

Supervisor Engine 720 (CAT6000-SUP720/MSFC3, 7600-SUP720/MSFC3)

Supervisor Engine 32 (CAT6000-SUP32/MSFC2A, 7600-SUP32/MSFC2A)

Supervisor Engine 2 (CAT6000-SUP2/MSFC2, 7600-SUP2/MSFC2)

Supervisor Engine 720 (CAT6000-SUP720/MSFC3, 7600-SUP720/MSFC3)

Supervisor Engine 720 Common Features

Supervisor Engine 720 with PFC3BXL

Supervisor Engine 720 with PFC3B

Supervisor Engine 720 with PFC3A

Supervisor Engine 720 Common Features

Integrated 720-Gbps Switch Fabric

64-MB bootflash device or CompactFlash adapter with 512 MB CompactFlash card (WS-CF-UPG=):

64-MB bootflash device (sup-bootflash:) supported in all releases

WS-CF-UPG= (sup-bootdisk:) supported in:

—Release 12.2(18)SXE5 and later releases

—Release 12.2(18)SXF and later releases

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_17277.htm

2 CompactFlash Type II slots (disk0: and disk1:)


Note Some Supervisor Engine 720 Release 12.2SX images are larger than the bootflash device and must be stored on a CompactFlash card.


Two Ethernet uplink ports:

1-MB packet buffer per port

Port 1— Gigabit Ethernet SFP

Port 2—Configurable as Gigabit Ethernet SFP or 10/100/1000 Mbps RJ-45

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Port grouping:

Number of ports: 2

Number of port groups: 1

Port ranges per port group: 1-2

Supervisor Engine 720 requires a high-capacity fan tray (see the "Fan Trays" section)

Supervisor Engine 720 with PFC3BXL

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SUP720-3BXL

7.82 A@42 V

Supervisor Engine 720 with PFC3BXL:

1-GB DRAM

Policy Feature Card 3BXL (PFC3BXL; see the "Policy Feature Cards" section)

Multilayer Switch Feature Card 3 (MSFC3):

1-GB DRAM

64-MB bootflash

12.2(17b)SXA

 

Note

There are no memory upgrade options for WS-SUP720-3BXL.

If you install WS-SUP720-3BXL=, upgrade the memory on any DFC3-equipped switching modules. See this document for DFC3 memory upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm


Supervisor Engine 720 with PFC3B

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SUP720-3B

6.72 A@42 V

Supervisor Engine 720 with PFC3B:

512-MB DRAM

Policy Feature Card 3B (PFC3B; see the "Policy Feature Cards" section)

Multilayer Switch Feature Card 3 (MSFC3):

512-MB DRAM

64-MB bootflash

12.2(17d)SXB1

 

Note

See this document for DFC3 memory upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm

Use WS-F6K-PFC3BXL= to upgrade a WS-SUP720-3B with a PFC3BXL. WS-F6K-PFC3BXL= includes 1 GB memory upgrades for the Supervisor Engine 720 and the MSFC3.

If you install WS-F6K-PFC3BXL=, upgrade the memory on any DFC3-equipped switching modules.

See this publication for more information about WS-F6K-PFC3BXL=:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_16220.htm

You can upgrade the WS-SUP720-3B memory to 1-GB DRAM on the Supervisor Engine 720 and 1-GB DRAM on the MSFC3.

If you upgrade the memory, upgrade the Supervisor Engine 720, the MSFC3, and any DFC3-equipped switching modules.

See this document for Supervisor Engine 720 and MSFC3 memory upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_15538.htm


Supervisor Engine 720 with PFC3A

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SUP720

7.50 A@42 V

Supervisor Engine 720 with PFC3A:

512-MB DRAM

Policy Feature Card 3A (PFC3A; see the "Policy Feature Cards" section)

Multilayer Switch Feature Card 3 (MSFC3):

512-MB DRAM

64-MB bootflash

12.2(14)SX

   

Note

See this document for DFC3 memory upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm

Use WS-F6K-PFC3BXL= to upgrade a WS-SUP720 with a PFC3BXL. WS-F6K-PFC3BXL= includes 1 GB memory upgrades for the Supervisor Engine 720 and the MSFC3.

If you install WS-F6K-PFC3BXL=, upgrade the memory on any DFC3-equipped switching modules.

See this publication for more information about WS-F6K-PFC3BXL=:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_16220.htm

Except with WS-F6K-PFC3BXL=, do not upgrade the memory on WS-SUP720 or on the MSFC3 on WS-SUP720.


Supervisor Engine 32 (CAT6000-SUP32/MSFC2A, 7600-SUP32/MSFC2A)


NoteSupervisor Engine 32 does not support this hardware:

WS-F6K-PFC3A Policy Feature Card 3A (PFC3A)

WS-F6K-PFC3BXL Policy Feature Card 3BXL (PFC3BXL)

DFCs (installed DFCs do not power up with a Supervisor Engine 32)

Switch Fabric Modules

These switching modules:
—WS-X6704-10GE 4-port 10-Gigabit Ethernet XENPAK
—WS-X6748-SFP 48-port Gigabit Ethernet SFP
—WS-X6724-SFP 24-port Gigabit Ethernet SFP
—WS-X6816-GBIC 16-port Gigabit Ethernet GBIC
—WS-X6748-GE-TX 48-port 10/100/1000 RJ-45

7600-SIP-600 SPA Interface Processor-600

Optical Services Modules (OSMs)

WS-X6182-2PA FlexWAN Module (the WS-X6582-2PA Enhanced FlexWAN Module is supported)

CISCO7603 3-slot chassis

These service modules:
—WS-SVC-WISM-1-K9 Wireless Services Module (WiSM)
—WS-SVC-AON-1-K9 Application-Oriented Networking (AON) Module
—WS-SVC-AGM-1-K9 Anomaly Guard Module
—WS-SVC-ADM-1-K9 Traffic Anomaly Detector Module
—WS-SVC-CSG-1 Content Services Gateway (CSG)
—WS-X6066-SLB-APC Content Switching Module (CSM)
—WS-X6066-SLB-S-K9 Content Switching Module with SSL (CSM-S)
—WS-SVC-PSD-1 Persistent Storage Device (PSD) Module
—WS-SVC-WLAN-1-K9 Wireless LAN service module
—WS-SVC-IPSEC-1 IPsec VPN acceleration services module

Supervisor Engine 32 does not support Cisco IOS SLB.

Supervisor Engine 32 cannot support these software features and commands:

Egress multicast replication

Multicast replication mode detection

All fabric configuration commands


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SUP32-10GE-3B

2.39 A@42 V

Supervisor Engine 32:

One 10/100/1000 Mbps RJ-45 port

WS-SUP32-10GE—two 10-Gigabit Ethernet ports (requires  XENPAKs)

WS-SUP32-GE—eight Gigabit Ethernet SFP ports (requires Gigabit Ethernet SFPs)

QoS port architecture (Rx/Tx): 2q8t/1p3q8t

256-MB DRAM with the " IP BASE SSH LAN ONLY" image (does not apply to the " IP BASE SSH LAN ONLY (MODULAR)" image)

512-MB DRAM with all other images

256-MB bootflash

Policy Feature Card 3B (PFC3B; see the "Policy Feature Cards" section)

Multilayer Switch Feature Card 2A (MSFC2A):

256-MB DRAM with the " IP BASE SSH LAN ONLY" image (does not apply to the " IP BASE SSH LAN ONLY (MODULAR)" image)

512-MB DRAM with all other images

64-MB bootflash

12.2(18)SXF

WS-SUP32-GE-3B

1.89 A@42 V

 

Note See this publication for Supervisor Engine 32 hardware information:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/6000hw/supe_gd/index.htm


Supervisor Engine 2 (CAT6000-SUP2/MSFC2, 7600-SUP2/MSFC2)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6K-S2U-MSFC2
WS-X6K-S2-MSFC2

3.46 A@42 V

Supervisor Engine 2 with Policy Feature Card 2 (PFC2):

ROMMON version 7.1(1) or later

32-MB bootflash device

256-MB DRAM (minimum)

dual-port 1000BASE-X GBIC uplinks

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Number of ports: 2
Number of port groups: 1
Port ranges per port group: 1-2

Multilayer Switch Feature Card 2 (MSFC2) with 256-MB DRAM (minimum)

12.2(17d)SXB

 

Note

Some Supervisor Engine 2 Release 12.2SX images are larger than the bootflash device. Supervisor Engine 2 ROMMON version 7.1(1) or later supports the MEM-C6K-ATA-1-64M= (64 MB) PCMCIA ATA FlashDisk device. See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/78_13488.htm

To use WS-X6K-S2-MSFC2 with 12.2SX releases, upgrade the memory.

MSFC2 DRAM—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_6953.htm

Supervisor Engine 2 DRAM—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12693.htm

Supervisor Engine 2 Bootflash—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12667.htm

Supervisor Engine 2 supports all GBICs supported by Release 12.2(17d)SXB and later releases.


Policy Feature Cards

Policy Feature Card Guidelines and Restrictions

Policy Feature Card 3BXL

Policy Feature Card 3B

Policy Feature Card 3A

Policy Feature Card Guidelines and Restrictions

A Supervisor Engine 2 always has a PFC2; there are no PFC options for Supervisor Engine 2.

The PFC2 supports a theoretical maximum of 128 K MAC addresses (32 K MAC addresses recommended maximum).

The PFC3 supports a theoretical maximum of 64 K MAC addresses (32 K MAC addresses recommended maximum).

The PFC3 partitions the hardware FIB table to route IPv4 unicast, IPv4 multicast, MPLS, and IPv6 unicast and multicast traffic in hardware. Traffic for routes that do not have entries in the hardware FIB table are routed by the MSFC in software.

The defaults for XL mode are:

IPv4 unicast and MPLS—512,000 routes

IPv4 multicast and IPv6 unicast and multicast—256,000 routes

The defaults for Non-XL mode are:

IPv4 unicast and MPLS—192,000 routes

IPv4 multicast and IPv6 unicast and multicast—32,000 routes


Note The size of the global internet routing table plus any local routes might exceed the non-XL mode default partition sizes.


These are the theoretical maximum numbers of routes for the supported protocols (the maximums are not supported simultaneously):

XL mode:

IPv4 and MPLS— Up to 1,007,000 routes

IPv4 multicast and IPv6 unicast and multicast—Up to 503,000 routes

Non-XL mode:

IPv4 and MPLS— Up to 239,000 routes

IPv4 multicast and IPv6 unicast and multicast—Up to 119,000 routes

Enter the mls cef maximum-routes command to repartition the hardware FIB table. IPv4 unicast and MPLS require one hardware FIB table entry per route. IPv4 multicast and IPv6 unicast and multicast require two hardware FIB table entries per route. Changing the partition for one protocol makes corresponding changes in the partitions of the other protocols. You must enter the reload command to put configuration changes made with the mls cef maximum-routes command into effect.


Note With a non-XL-mode system, if your requirements cannot be met by repartitioning the hardware FIB table, upgrade components as necessary to operate in XL mode.


You cannot use one type of PFC3 (PFC3BXL, PFC3B, or PFC3A) on one supervisor engine and a different type on the other supervisor engine for redundancy. You must use identical policy feature cards for redundancy.

With Release 12.2(17d)SXB and later releases, enter the show platform hardware pfc mode command to display the PFC3 mode.

With Release 12.2(17b)SXA and Release 12.2(17b)SXA2, enter the show platform earl-mode command to display the PFC3 mode.

PFC3A—These restrictions apply to a configuration with a PFC3A and these DFCs:

PFC3A and DFC3A—No restrictions (PFC3A mode).

PFC3A and DFC3B—The PFC3A restricts DFC3B functionality: the DFC3B functions as a DFC3A (PFC3A mode).

PFC3A and DFC3BXL—The PFC3A restricts DFC3BXL functionality: the DFC3BXL functions as a DFC3A (PFC3A mode).

PFC3A and DFC3C—The PFC3A restricts DFC3C functionality: the DFC3C functions as a DFC3A (PFC3A mode).

PFC3A and DFC3CXL—The PFC3A restricts DFC3CXL functionality: the DFC3CXL functions as a DFC3A (PFC3A mode).

PFC3B—These restrictions apply to a configuration with a PFC3B and these DFCs:

PFC3B and DFC3A—PFC3B functionality is restricted by the DFC3A: after a reload with a DFC3A-equipped module installed, the PFC3B functions as a PFC3A (PFC3A mode).

PFC3B and DFC3B—No restrictions (PFC3B mode).

PFC3B and DFC3BXL—The PFC3B restricts DFC3BXL functionality: after a reload with a DFC3BXL-equipped module installed, the DFC3BXL functions as a DFC3B (PFC3B mode).

PFC3B and DFC3C—The PFC3B restricts DFC3C functionality: the DFC3C functions as a DFC3B (PFC3B mode).

PFC3B and DFC3CXL—The PFC3B restricts DFC3CXL functionality: the DFC3CXL functions as a DFC3B (PFC3B mode).

PFC3BXL—These restrictions apply to a configuration with a PFC3BXL and these DFCs:

PFC3BXL and DFC3A—PFC3BXL functionality is restricted by the DFC3A: after a reload with a DFC3A-equipped module installed, the PFC3BXL functions as a PFC3A (PFC3A mode).

PFC3BXL and DFC3B—PFC3BXL functionality is restricted by the DFC3B: after a reload with a DFC3B-equipped module installed, the PFC3BXL functions as a PFC3B (PFC3B mode).

PFC3BXL and DFC3BXL—No restrictions (PFC3BXL mode).

PFC3BXL and DFC3C—Each restricts the functionality of the other: the PFC3BXL functions as a PFC3B and the DFC3C functions as a DFC3B (PFC3B mode).

PFC3BXL and DFC3CXL—The PFC3BXL restricts DFC3CXL functionality: the DFC3CXL functions as a DFC3BXL (PFC3BXL mode).

Summary of the PFC modes:

PFC3A mode—Operating mode with a PFC3A or any DFC3As

PFC3B mode—Operating mode with PFC3B and any DFC3Bs or DFC3BXLs

PFC3BXL mode—Operating mode with PFC3BXL and any DFC3BXLs

The features that require the PFC3BXL or PFC3B are not supported in PFC3A mode.

With a PFC3BXL or PFC3B and no DFC3A-equipped switching modules installed at bootup, any DFC3A-equipped switching module installed after bootup remain powered down.

To use DFC3A-equipped switching modules with a PFC3BXL or PFC3B, the DFC3A-equipped switching modules must be installed at bootup.

To use DFC3B-equipped switching modules with a PFC3BXL, the DFC3B-equipped switching modules must be installed at bootup.

Policy Feature Card 3BXL

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6K-PFC3BXL

2.57 A@42 V

Policy Feature Card 3BXL (PFC3BXL)

 

Supported only with Supervisor Engine 720

12.2(17b)SXA

Note

There are no memory upgrade options for WS-F6K-PFC3BXL.

Use WS-F6K-PFC3BXL= to upgrade a WS-SUP720 or WS-SUP720-3B with a PFC3BXL. WS-F6K-PFC3BXL= includes 1 GB memory upgrades for the Supervisor Engine 720 and the MSFC3. See this publication for more information:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_16220.htm


Policy Feature Card 3B

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6K-PFC3B

2.25 A@42 V

Policy Feature Card 3B (PFC3B)

With Supervisor Engine 720

12.2(17d)SXB1

With Supervisor Engine 32

12.2(18)SXF

Note

There are no memory upgrade options for WS-F6K-PFC3B.

Use WS-F6K-PFC3BXL= to upgrade a WS-SUP720-3B with a PFC3BXL. WS-F6K-PFC3BXL= includes 1 GB memory upgrades for the Supervisor Engine 720 and the MSFC3. See this publication for more information:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_16220.htm


Policy Feature Card 3A

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6K-PFC3A

2.25 A@42 V

Policy Feature Card 3A (PFC3A)

 

Supported only with Supervisor Engine 720

12.2(14)SX

Note

There are no memory upgrade options for WS-F6K-PFC3A.

WS-F6K-PFC3A is available only on WS-SUP720. It is not orderable.


Distributed and Centralized Forwarding Cards

Distributed Forwarding Card 3CXL

Distributed Forwarding Card 3C

Distributed Forwarding Card 3BXL

Distributed Forwarding Card 3B

Distributed Forwarding Card 3A

Distributed Forwarding Card (WS-F6K-DFC)

Centralized Forwarding Card (WS-X6700-CFC)


Note See the "Policy Feature Cards" section for Policy Feature Cards (PFC) and Distributed Forwarding Card (DFC) restrictions.


Distributed Forwarding Card 3CXL

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6700-DFC3CXL

2.35 A@42 V

Distributed Forwarding Card 3CXL (DFC3CXL) for use on CEF720 modules

 

Supported only with Supervisor Engine 720 and WS-X6708-10GE

12.2(18)SXF5


Distributed Forwarding Card 3C

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6700-DFC3C

1.65 A@42 V

Distributed Forwarding Card 3C (DFC3C) for use on CEF720 modules

 

Supported only with Supervisor Engine 720 and WS-X6708-10GE

12.2(18)SXF5


Distributed Forwarding Card 3BXL

WS-F6700-DFC3BXL

WS-F6K-DFC3BXL

WS-F6700-DFC3BXL

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6700-DFC3BXL

3.30 A@42 V

Distributed Forwarding Card 3BXL (DFC3BXL) for use on CEF720 modules

 

Supported only with Supervisor Engine 720

12.2(17d)SXB6

Note

WS-F6700-DFC3BXL uses memory that is installed on the switching module.

See this publication for information about WS-F6700-DFC3BXL upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_15893.htm


WS-F6K-DFC3BXL

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6K-DFC3BXL

1.47 A@42 V

Distributed Forwarding Card 3BXL (DFC3BXL) for use on dCEF256 and CEF256 modules

 

Supported only with Supervisor Engine 720

12.2(18)SXD3

Note

See this publication for information about WS-F6K-DFC3BXL memory upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm

Supervisor Engine 720 supports a WS-F6K-DFC3BXL on these WS-X6516-GBIC switching module hardware revisions:

Lower than 5.0

5.5 and higher

Supervisor Engine 720 does not support a DFC3 on WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4. With a Supervisor Engine 720 and with a DFC3 installed, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 do not power up.

With a Supervisor Engine 720 but without a DFC3, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 operate in bus mode.

See external field notice 24494 for more information about Supervisor Engine 720 and a DFC3 on WS-X6516-GBIC switching modules:

http://www.cisco.com/warp/public/770/fn24494.shtml


Distributed Forwarding Card 3B

WS-F6700-DFC3B

WS-F6K-DFC3B

WS-F6700-DFC3B

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6700-DFC3B

2.70 A@42 V

Distributed Forwarding Card 3B (DFC3B) for use on CEF720 modules

 

Supported only with Supervisor Engine 720

12.2(17d)SXB6

Note

WS-F6700-DFC3B uses memory that is installed on the switching module.

See this publication for information about WS-F6700-DFC3B upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_15893.htm


WS-F6K-DFC3B

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6K-DFC3B

1.67 A@42 V

Distributed Forwarding Card 3B (DFC3B) for use on dCEF256 and CEF256 modules

 

Supported only with Supervisor Engine 720

12.2(18)SXD3

Note

See this publication for information about WS-F6K-DFC3B memory upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm

Supervisor Engine 720 supports a WS-F6K-DFC3B on these WS-X6516-GBIC switching module hardware revisions:

Lower than 5.0

5.5 and higher

Supervisor Engine 720 does not support a DFC3 on WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4. With a Supervisor Engine 720 and with a DFC3 installed, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 do not power up.

With a Supervisor Engine 720 but without a DFC3, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 operate in bus mode.

See external field notice 24494 for more information about Supervisor Engine 720 and a DFC3 on WS-X6516-GBIC switching modules:

http://www.cisco.com/warp/public/770/fn24494.shtml


Distributed Forwarding Card 3A

WS-F6700-DFC3A

WS-F6K-DFC3A

WS-F6700-DFC3A

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6700-DFC3A

3.00 A@42 V

Distributed Forwarding Card 3A (DFC3A) for use on CEF720 modules

 

Supported only with Supervisor Engine 720

12.2(17a)SX

Note

WS-F6700-DFC3A uses memory that is installed on the switching module.

See this publication for information about WS-F6700-DFC3A memory upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm


WS-F6K-DFC3A

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6K-DFC3A

2.57 A@42 V

Distributed Forwarding Card 3A (DFC3A) for use on dCEF256 and CEF256 modules

 

Supported only with Supervisor Engine 720

12.2(14)SX

Note

See this publication for information about WS-F6K-DFC3A memory upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm

Supervisor Engine 720 supports a WS-F6K-DFC3A on these WS-X6516-GBIC switching module hardware revisions:

Lower than 5.0

5.5 and higher

Supervisor Engine 720 does not support a DFC3 on WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4. With a Supervisor Engine 720 and with a DFC3 installed, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 do not power up.

With a Supervisor Engine 720 but without a DFC3, WS-X6516-GBIC switching module hardware revisions 5.0 through 5.4 operate in bus mode.

See external field notice 24494 for more information about Supervisor Engine 720 and a DFC3 on WS-X6516-GBIC switching modules:

http://www.cisco.com/warp/public/770/fn24494.shtml


Distributed Forwarding Card (WS-F6K-DFC)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6K-DFC

2.10 A@42 V

Distributed Forwarding Card (DFC) for use on dCEF256 and CEF256 modules

 

Supported only with Supervisor Engine 2

Note Not supported in Release 12.2(18)SXE and Rebuilds

12.2(17d)SXB

Note

Release 12.2(18)SXE does not support Supervisor Engine 2.

WS-F6K-DFC requires a Switch Fabric Module.

See this publication for information about WS-F6K-DFC memory upgrades:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_12409.htm


Centralized Forwarding Card (WS-X6700-CFC)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6700-CFC

0.75 A@42 V

Centralized Forwarding Card (CFC) for use on CEF720 modules

 

Supported only with Supervisor Engine 720

12.2(17a)SX

Note There are no memory upgrade options for WS-X6700-CFC.


Switch Fabric Modules


NoteSwitch fabric modules are supported only with Supervisor Engine 2.

Except in 13-slot chassis, WS-X6500-SFM2 and WS-C6500-SFM can be used together to provide redundancy.

3-slot chassis do not support WS-X6500-SFM2 or WS-C6500-SFM.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6500-SFM2

3.09 A@42 V

Switch Fabric Module, version 2, to support dCEF256 modules

 

Supported only with Supervisor Engine 2

12.2(17d)SXB

Note WS-C6500-SFM2 supports all chassis except 3-slot chassis.

WS-C6500-SFM

2.79 A@42 V

Switch Fabric Module to support dCEF256 modules

 

Supported only with Supervisor Engine 2

12.2(17d)SXB

Note WS-C6500-SFM does not support 13-slot chassis or 3-slot chassis.


Transceivers

X2 Modules

XENPAKs

Small Form-Factor Pluggable (SFP) Modules

Gigabit Interface Converters (GBICs)

X2 Modules


Note WS-X6708-10GE does not support X2 modules shipped before the release of the WS-X6708-10GE switching module. The unsupported X2 modules are labeled with a number that ends with -01.


Product ID
(append "=" for spares)
Product Description
Minimum Software Version
X2-10GB-CX4

10GBASE for CX4 (copper) cable

12.2(18)SXF5

X2-10GB-ER

10GBASE-ER Serial 1550-nm extended-reach, single-mode fiber (SMF), dispersion-shifted fiber (DSF)

12.2(18)SXF5

X2-10GB-LR

10GBASE-LR Serial 1310-nm long-reach, single-mode fiber (SMF), dispersion-shifted fiber (DSF)

12.2(18)SXF5

X2-10GB-LX4

10GBASE-LX4 Serial 1310-nm multimode (MMF)

12.2(18)SXF5

X2-10GB-SR

10GBASE-SR Serial 850-nm short-reach multimode (MMF)

12.2(18)SXF5


XENPAKs

Product ID
(append "=" for spares)
Product Description
Minimum Software Version
XENPAK-10GB-ZR

10GBASE for any SMF type

12.2(18)SXF

XENPAK-10GB-LW

10GBASE-LW XENPAK Module with WAN PHY for SMF

12.2(18)SXE

Note XENPAK-10GB-LW operates at an interface speed compatible with SONET/SDH OC-192/STM-64 and supports transmission at a data rate of 9.6Gbps.

DWDM-XENPAK

10GBASE dense wavelength-division multiplexing (DWDM) 100-GHz ITU grid

12.2(18)SXE

WDM-XENPAK-REC

10GBASE receive-only wavelength division multiplexing (WDM)

12.2(18)SXE

XENPAK-10GB-CX4

10GBASE for CX4 (copper) cable

12.2(17d)SXB1

XENPAK-10GB-SR

10GBASE-SR Serial 850-nm short-reach multimode (MMF)

12.2(17a)SX1

XENPAK-10GB-LX4

10GBASE-LX4 Serial 1310-nm multimode (MMF)

12.2(17a)SX1

XENPAK-10GB-ER

10GBASE-ER Serial 1550-nm extended-reach, single-mode fiber (SMF), dispersion-shifted fiber (DSF)

12.2(17a)SX

Note Release 12.2(17d)SXB1 and later releases do not support XENPAK-10GB-ER units with Part No. 800-24557-01, as described in this external field notice (CSCee47030):

http://www.cisco.com/warp/public/770/fn29736.shtml

XENPAK-10GB-LR

10GBASE-LR Serial 1310-nm long-reach, single-mode fiber (SMF), dispersion-shifted fiber (DSF)

12.2(17a)SX


Small Form-Factor Pluggable (SFP) Modules

These sections describe SFPs:

Gigabit Ethernet SFPs

Fast Ethernet SFPs

Gigabit Ethernet SFPs

Product ID
(append "=" for spares)
Product Description
Minimum Software Version
GLC-BX-D

1000BASE-BX10 SFP module for single-strand SMF, 1490-nm TX/1310-nm RX wavelength

12.2(18)SXE

GLC-BX-U

1000BASE-BX10 SFP module for single-strand SMF, 1310-nm TX/1490-nm RX wavelength

12.2(18)SXE

GLC-ZX-SM

1000BASE-ZX SFP module

12.2(17d)SXB1

CWDM-SFP

1000BASE coarse wavelength-division multiplexing (CWDM) SFP module

12.2(17a)SX

GLC-T

1000BASE-T SFP module

12.2(17a)SX

GLC-LH-SM

1000BASE-LX/LH SFP

12.2(17a)SX

GLC-SX-MM

1000BASE-SX SFP

12.2(14)SX


Fast Ethernet SFPs


Note Only WS-X6148-FE-SFP supports these Fast Ethernet SFPs.


Product ID
(append "=" for spares)
Product Description
Minimum Software Version
GLC-FE-100BX-U

100BASE-BX10-U SFP

12.2(18)SXF2

GLC-FE-100BX-D

100BASE-BX10-D SFP

12.2(18)SXF2

GLC-FE-100EX

100BASEEX SFP

12.2(18)SXF

GLC-FE-100ZX

100BASEZX SFP

12.2(18)SXF

GLC-FE-100FX

100BASEFX SFP

12.2(18)SXF

GLC-FE-100LX

100BASELX SFP

12.2(18)SXF


Gigabit Interface Converters (GBICs)


Note The support listed in this section applies to all modules that use GBICs, including OSM LAN ports and OSM Gigabit Ethernet WAN ports.


Product ID
(append "=" for spares)
Product Description
Minimum Software Version
WDM-GBIC-REC

Receive-only wavelength division multiplexing (WDM) GBIC

12.2(18)SXE

DWDM-GBIC

Dense wavelength division multiplexing (DWDM) GBIC

12.2(17a)SX

CWDM-GBIC

Coarse wave division multiplexing (CWDM) GBIC

12.2(14)SX

WS-G5483

1000BASET GBIC

12.2(14)SX

WS-G5484

Short wavelength, 1000BASE-SX

12.2(14)SX

WS-G5486

Long wavelength/long haul, 1000BASE-LX/LH

12.2(14)SX

WS-G5487

Extended distance, 1000BASE-ZX

12.2(14)SX


10-Gigabit Ethernet Switching Modules

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6708-10G-3C
(WS-X6708-10GE with
WS-F6700-DFC3C)

10.58A @42 V

8-port 10-Gigabit Ethernet X2module

dCEF720

Supports egress multicast replication

QoS port architecture (Rx/Tx): 8q4t/1p7q4t

Dual switch-fabric connections

Number of ports: 8
Number of port groups: 8
Port ranges per port group: 1 port in each group

 
WS-X6708-10G-3CXL
(WS-X6708-10GE with
WS-F6700-DFC3CXL)

11.28A @ 42V

 

Supported only with Supervisor Engine 720

12.2(18)SXF5

Note

Installation of a WS-X6708-10GE switching module in a chassis other than the following prevents operation at levels that are fully NEBS-compliant:

WS-C6503-E

WS-C6504-E

WS-C6506-E

WS-C6509-E

WS-C6509-NEB-A

CISCO7604

CISCO7609

WS-X6708-10G-3C and WS-X6708-10G-3CXL are the orderable product IDs.

The front panel is labeled WS-X6708-10GE.

Cisco IOS software commands display WS-X6708-10GE with either WS-F6700-DFC3C or WS-F6700-DFC3CXL.

WS-X6708-10GE ports do not support VACL capture. (CSCsb59015)

WS-X6708-10GE is not supported in the WS-C6503 and CISCO7603 chassis.

In a 13-slot chassis, WS-X6708-10GE is supported only in slots 9 through 13 and does not power up in other slots.

On WS-X6708-10GE ports, STP BPDUs are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6708-10GE ports that interconnect network devices.

WS-X6704-10GE

6.28 A@42 V

4-port 10-Gigabit Ethernet XENPAK

CEF720 with WS-X6700-CFC (adds 0.75 A@42 V)

dCEF720 with WS-F6700-DFC3BXL (adds 3.30 A@42 V)

dCEF720 with WS-F6700-DFC3B (adds 2.70 A@42 V)

dCEF720 with WS-F6700-DFC3A (adds 3.00 A@42 V)

Supports egress multicast replication

QoS port architecture (Rx/Tx):

With DFC3: 8q8t/1p7q8t

With CFC: 1q8t/1p7q8t

Dual switch-fabric connections

Number of ports: 4
Number of port groups: 4
Port ranges per port group: 1 port in each group

 

Supported only with Supervisor Engine 720

12.2(17a)SX

Note

WS-X6704-10GE requires one of the following:

WS-F6700-DFC3BXL (3.30 A@42 V)

WS-F6700-DFC3B (2.70 A@42 V)

WS-F6700-DFC3A (3.00 A@42 V)

WS-X6700-CFC (0.75 A@42 V)

WS-X6704-10GE ships with WS-X6700-CFC installed unless ordered with WS-F6700-DFC3BXL, WS-F6700-DFC3B, or WS-F6700-DFC3A.

WS-X6704-10GE is supported in the WS-C6503-E chassis.

WS-X6704-10GE is not supported in the WS-C6503 and CISCO7603 chassis.

In a 13-slot chassis, WS-X6704-10GE is supported only in slots 9 through 13 and does not power up in other slots.

On WS-X6704-10GE ports, STP BPDUs are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6704-10GE ports that interconnect network devices.

WS-X6502-10GE

3.30 A@42 V

1-port 10-Gigabit Ethernet

With Supervisor Engine 720:

dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)

dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)

dCEF256 with WS-F6K-DFC3A (adds 2.57 A@42 V)

With Supervisor Engine 2, dCEF256 with WS-F6K-DFC (adds 2.10 A@42 V)

QoS port architecture (Rx/Tx): 1p1q8t/1p2q1t

Number of ports: 1
Number of port groups: 1
Port ranges per port group: 1 port in 1 group

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

Note WS-X6502-10GE does not support ISL encapsulation.

Optical Interface Module (OIM) for WS-X6502-10GE
 WS-G6488

10GBASE-LR serial 1310 nm long-reach OIM

12.2(14)SX

 WS-G6483

10GBASE-ER serial 1550 nm extended-reach OIM

12.2(14)SX


Gigabit Ethernet Switching Modules

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6748-SFP

5.32 A@42 V

48-port Gigabit Ethernet SFP

CEF720 with WS-X6700-CFC (adds 0.75 A@42 V)

dCEF720 with WS-F6700-DFC3BXL (adds 3.30 A@42 V)

dCEF720 with WS-F6700-DFC3B (adds 2.70 A@42 V)

dCEF720 with WS-F6700-DFC3A (adds 3.00 A@42 V)

Supports egress multicast replication

QoS architecture:

With DFC3: 2q8t/1p3q8t

With CFC: 1q8t/1p3q8t

Dual switch-fabric connections

Number of ports: 48
Number of port groups: 4
Port ranges per port group:
 1,  3,  5,  7,  9, 11, 13, 15, 17, 19, 21, 23
 2,  4,  6,  8, 10, 12, 14, 16, 18, 20, 22, 24
25, 27, 29, 31, 33, 35, 37, 39, 41, 43, 45, 47
26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46, 48

 

Supported only with Supervisor Engine 720

12.2(17d)SXB

Note

WS-X6748-SFP requires one of the following:

WS-F6700-DFC3BXL (3.30 A@42 V)

WS-F6700-DFC3B (2.70 A@42 V)

WS-F6700-DFC3A (3.00 A@42 V)

WS-X6700-CFC (0.75 A@42 V)

WS-X6748-SFP ships with WS-X6700-CFC installed unless ordered with WS-F6700-DFC3BXL, WS-F6700-DFC3B, or WS-F6700-DFC3A.

WS-X6748-SFP is supported in the WS-C6503-E chassis.

WS-X6748-SFP is not supported in the WS-C6503 and CISCO7603 chassis.

In a 13-slot chassis, WS-X6748-SFP is supported only in slots 9 through 13 and does not power up in other slots.

On WS-X6748-SFP ports, STP BPDUs are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6748-SFP ports that interconnect network devices.

See the "Small Form-Factor Pluggable (SFP) Modules" section.

WS-X6724-SFP

2.23 A@42 V

24-port Gigabit Ethernet SFP

CEF720 with WS-X6700-CFC (adds 0.75 A@42 V)

dCEF720 with WS-F6700-DFC3BXL (adds 3.30 A@42 V)

dCEF720 with WS-F6700-DFC3B (adds 2.70 A@42 V)

dCEF720 with WS-F6700-DFC3A (adds 3.00 A@42 V)

Supports egress multicast replication

QoS architecture:

With DFC3: 2q8t/1p3q8t

With CFC: 1q8t/1p3q8t

Number of ports: 24
Number of port groups: 2
Port ranges per port group: 1-12, 13-24

 

Supported only with Supervisor Engine 720

12.2(17a)SX

Note

WS-X6724-SFP requires one of the following:

WS-F6700-DFC3BXL (3.30 A@42 V)

WS-F6700-DFC3B (2.70 A@42 V)

WS-F6700-DFC3A (3.00 A@42 V)

WS-X6700-CFC (0.75 A@42 V)

WS-X6724-SFP ships with WS-X6700-CFC installed unless ordered with WS-F6700-DFC3BXL, WS-F6700-DFC3B, or WS-F6700-DFC3A.

WS-X6724-SFP is supported in the WS-C6503-E chassis.

WS-X6724-SFP is not supported in the WS-C6503 and CISCO7603 chassis.

On WS-X6724-SFP ports, STP BPDUs are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6724-SFP ports that interconnect network devices.

See the "Small Form-Factor Pluggable (SFP) Modules" section.

WS-X6816-GBIC
 

16-port Gigabit Ethernet GBIC

dCEF256

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Dual switch-fabric connections

Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16

 

3.84 A@42 V

With Supervisor Engine 720

12.2(14)SX

5.94 A@42 V

With Supervisor Engine 2

12.2(17d)SXB

Note

WS-X6816-GBIC requires one of these for use with Supervisor Engine 720:

WS-F6K-DFC3BXL (adds 1.47 A@42 V)

WS-F6K-DFC3B (adds 1.67 A@42 V)

WS-F6K-DFC3A (adds 2.57 A@42 V)

WS-X6816-GBIC requires WS-F6K-DFC for use with Supervisor Engine 2.

In a 13-slot chassis, WS-X6816-GBIC is supported only in slots 9 through 13 and does not power up in other slots.

WS-X6516A-GBIC

3.62 A@42 V

16-port Gigabit Ethernet GBIC

CEF256

With Supervisor Engine 720:

dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)

dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)

dCEF256 with WS-F6K-DFC3A (adds 2.57 A@42 V)

With Supervisor Engine 2, dCEF256 with WS-F6K-DFC (adds 2.10 A@42 V)

1-MB per-port packet buffers

Supports egress multicast replication

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6516-GBIC

3.40 A@42 V

16-port Gigabit Ethernet GBIC

CEF256

With Supervisor Engine 720:

dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)

dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)

dCEF256 with WS-F6K-DFC3A (adds 2.57 A@42 V)

With Supervisor Engine 2, dCEF256 with WS-F6K-DFC (adds 2.10 A@42 V)

512-KB per-port packet buffers

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

Note

Supervisor Engine 720 supports a DFC3 on these WS-X6516-GBIC hardware revisions:

Lower than 5.0

5.5 and higher

Supervisor Engine 720 does not support a DFC3 on WS-X6516-GBIC hardware revisions 5.0 through 5.4. With a Supervisor Engine 720 and with a DFC3 installed, WS-X6516-GBIC hardware revisions 5.0 through 5.4 do not power up.

With a Supervisor Engine 720 but without a DFC3, WS-X6516-GBIC hardware revisions 5.0 through 5.4 operate in bus mode.

See external field notice 24494 for more information:

http://www.cisco.com/warp/public/770/fn24494.shtml

WS-X6416-GBIC

2.81 A@42 V

16-port Gigabit Ethernet GBIC

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6416-GE-MT

2.50 A@42 V

16-Port Gigabit Ethernet MT-RJ

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6316-GE-TX

5.15 A@42 V

16-port Gigabit Ethernet RJ-45

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6408A-GBIC

2.00 A@42 V

8-port Gigabit Ethernet GBIC

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Number of ports: 8
Number of port groups: 1
Port ranges per port group: 1-8

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6408-GBIC

2.00 A@42 V

8-port Gigabit Ethernet GBIC

QoS port architecture (Rx/Tx): 1q4t/2q2t

Number of ports: 8
Number of port groups: 1
Port ranges per port group: 1-8

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

Note

Caveat CSCec65943 prevents support of the WS-X6408-GBIC switching module in Release 12.2(17a)SX.

Caveat CSCec65943 is resolved in Release 12.2(17a)SX1 and later releases.


Power over Ethernet Daughtercards


Note The power over Ethernet (PoE) daughtercard "Power Required" values do not include the power drawn by phones.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-F6K-FE48X2-AF

0.42 A@42 V

IEEE 802.3af PoE daughtercard for WS-X6148X2-RJ-45 and WS-X6196-RJ-21.

 

With Supervisor Engine 720

12.2(18)SXF

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(18)SXF2

WS-F6K-GE48-AF

0.18 A@42 V

IEEE 802.3af PoE daughtercard for WS-X6548-GE-TX and WS-X6148-GE-TX

 

With Supervisor Engine 720

12.2(17d)SXB

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-F6K-FE48-AF

0.18 A@42 V

IEEE 802.3af PoE daughtercard for WS-X6148-RJ-45 and WS-X6148-RJ-21

 

With Supervisor Engine 720

12.2(17d)SXB

With Supervisor Engine 2

12.2(17d)SXB

WS-F6K-VPWR-GE

0.42 A@42 V

PoE daughtercard for WS-X6548-GE-TX and WS-X6148-GE-TX

 

With Supervisor Engine 720

12.2(17a)SX

With Supervisor Engine 2

12.2(17d)SXB

WS-F6K-VPWR

None

PoE daughtercard for WS-X6348-RJ-45, WS-X6348-RJ-21V, WS-X6148-RJ-45, and WS-X6148-RJ-21

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 2

12.2(17d)SXB


10/100/1000 Ethernet Switching Modules

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6748-GE-TX

7.00 A@42 V

48-port 10/100/1000 RJ-45

CEF720 with WS-X6700-CFC (adds 0.75 A@42 V)

dCEF720 with WS-F6700-DFC3BXL (adds 3.30 A@42 V)

dCEF720 with WS-F6700-DFC3B (adds 2.70 A@42 V)

dCEF720 with WS-F6700-DFC3A (adds 3.00 A@42 V)

Supports egress multicast replication

QoS architecture:

With DFC3: 2q8t/1p3q8t

With CFC: 1q8t/1p3q8t

Dual switch-fabric connections

Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48

 

Supported only with Supervisor Engine 720

12.2(17a)SX

Note

WS-X6748-GE-TX requires one of the following:

WS-F6700-DFC3BXL (3.30 A@42 V)

WS-F6700-DFC3B (2.70 A@42 V)

WS-F6700-DFC3A (3.00 A@42 V)

WS-X6700-CFC (0.75 A@42 V)

WS-X6748-GE-TX ships with WS-X6700-CFC installed unless ordered with WS-F6700-DFC3BXL, WS-F6700-DFC3B, or WS-F6700-DFC3A.

WS-X6748-GE-TX is supported in the WS-C6503-E chassis.

WS-X6748-GE-TX is not supported in the WS-C6503 and CISCO7603 chassis.

In a 13-slot chassis, WS-X6748-GE-TX is supported only in slots 9 through 13 and does not power up in other slots.

On WS-X6748-GE-TX ports, STP BPDUs are not exempt from Traffic Storm Control suppression. Do not configure Traffic Storm Control on STP-protected WS-X6748-GE-TX ports that interconnect network devices.

WS-X6548-GE-TX
WS-X6548V-GE-TX
WS-X6548-GE-45AF

2.98 A@42 V
3.40 A@42 V
3.16 A@42 V

48-port 10/100/1000 Mbps

RJ-45

CEF256

WS-X6548-GE-TX supports WS-F6K-VPWR-GE and WS-F6K-GE48-AF

WS-X6548V-GE-TX has WS-F6K-VPWR-GE

WS-X6548-GE-45AF has WS-F6K-GE48-AF

QoS port architecture (Rx/Tx): 1q2t/1p2q2t

Number of ports: 48
Number of port groups: 2
Port ranges per port group: 1-24, 25-48

 

With Supervisor Engine 720
(except WS-F6K-GE48-AF)

12.2(17a)SX

WS-F6K-GE48-AF with Supervisor Engine 720

12.2(17d)SXB

With Supervisor Engine 32

12.2(18)SXF

WS-F6K-GE48-AF with Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-F6K-GE48-AF with Supervisor Engine 2

12.2(17d)SXB

Note

Release 12.2(17b)SXA and later releases provide support for more than 1 Gbps of traffic per EtherChannel on the WS-X6548-GE-TX (and voice-power daughtercard equipped) switching modules.

WS-X6548-GE-TX and WS-X6548V-GE-TX do not support these features:

With Release 12.2(17a)SX and Release 12.2(17a)SX1, more than 1 Gbps of traffic per EtherChannel

WS-F6K-DFC3A

ISL trunking

Jumbo frames

802.1Q tunneling

Traffic storm control

WS-X6148A-GE-TX
WS-X6148A-GE-45AF

2.50 A@42 V
2.68 A@42 V

48-port 10/100/1000 Mbps

RJ-45

WS-X6148A-GE-TX supports WS-F6K-GE48-AF

WS-X6148A-GE-45AF has WS-F6K-GE48-AF

QoS port architecture (Rx/Tx): 1q2t/1p3q8t

Number of ports: 48
Number of port groups: 6
Port ranges per port group: 1-8, 9-16, 17-24, 25-32, 33-40, 41-48

The aggregate bandwidth of each port group is 1 Gbps.

 

With Supervisor Engine 720

12.2(18)SXF

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(18)SXF2

Note WS-X6148A-GE-TX and WS-X6148A-GE-45AF do not support these features:

WS-F6K-DFC3A, WS-F6K-DFC3B, or WS-F6K-DFC3BXL

Traffic storm control

WS-X6148-GE-TX
WS-X6148V-GE-TX
WS-X6148-GE-45AF

2.47 A@42 V
2.89 A@42 V
2.65 A@42 V

48-port 10/100/1000 Mbps

RJ-45

WS-X6148-GE-TX supports WS-F6K-VPWR-GE and WS-F6K-GE48-AF

WS-X6148V-GE-TX has WS-F6K-VPWR-GE

WS-X6148-GE-45AF has WS-F6K-GE48-AF

QoS port architecture (Rx/Tx): 1q2t/1p2q2t

Number of ports: 48
Number of port groups: 2
Port ranges per port group: 1-24, 25-48

 

With Supervisor Engine 720
(except WS-F6K-GE48-AF)

12.2(17a)SX

WS-F6K-GE48-AF with Supervisor Engine 720

12.2(17d)SXB

With Supervisor Engine 32

12.2(18)SXF

WS-F6K-GE48-AF with Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-F6K-GE48-AF with Supervisor Engine 2

12.2(17d)SXB

Note WS-X6148-GE-TX, WS-X6148V-GE-TX, and WS-X6148-GE-45AF do not support these features:

More than 1 Gbps of traffic per EtherChannel

WS-F6K-DFC3A, WS-F6K-DFC3B, or WS-F6K-DFC3BXL

ISL trunking

Jumbo frames

802.1Q tunneling

Traffic storm control

WS-X6516-GE-TX

3.45 A@42 V

16-port 10/100/1000BASE-T

CEF256

With Supervisor Engine 720:

dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)

dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)

dCEF256 with WS-F6K-DFC3A (adds 2.57 A@42 V)

With Supervisor Engine 2, dCEF256 with WS-F6K-DFC (adds 2.10 A@42 V)

QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t

Number of ports: 16
Number of port groups: 2
Port ranges per port group: 1-8, 9-16

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB


Fast Ethernet Switching Modules

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6148-FE-SFP

2.30 A@42 V

48-port 100BASE-FX

Requires Fast Ethernet SFPs

QoS port architecture (Rx/Tx): 1p1q4t/1p3q8t

Number of ports: 48
Number of port groups: 3
Port ranges per port group: 1-16, 17-32, and 33-48

 

With Supervisor Engine 720

12.2(18)SXF

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(18)SXF2

WS-X6524-100FX-MM

1.90 A@42 V

24-port 100FX Ethernet multimode

CEF256

With Supervisor Engine 720:

dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)

dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)

dCEF256 with WS-F6K-DFC3A (adds 2.57 A@42 V)

With Supervisor Engine 2, dCEF256 with WS-F6K-DFC (adds 2.10 A@42 V)

QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t

Number of ports: 24
Number of port groups: 1
Port ranges per port group: 1-24

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6324-100FX-SM
WS-X6324-100FX-MM

1.52 A@42 V
1.52 A@42 V

24-port 100FX Ethernet

Single mode and multimode MT-RJ

128-KB per-port packet buffers

QoS port architecture (Rx/Tx): 1q4t/2q2t

Number of ports: 24
Number of port groups: 2
Port ranges per port group: 1-12, 13-24

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6224-100FX-MT

1.90 A@42 V

24-port 100FX Ethernet Multimode MT-RJ

QoS port architecture (Rx/Tx): 1q4t/2q2t

Number of ports: 24
Number of port groups: 2
Port ranges per port group: 1-12, 13-24

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB


Ethernet/Fast Ethernet (10/100) Switching Modules

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6548-RJ-45

2.90 A@42 V

48-port 10/100TX RJ-45

CEF256

With Supervisor Engine 720:

dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)

dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)

dCEF256 with WS-F6K-DFC3A (adds 2.57 A@42 V)

With Supervisor Engine 2, dCEF256 with WS-F6K-DFC (adds 2.10 A@42 V)

QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t

Number of ports: 48
Number of port groups: 1
Port ranges per port group: 1-48

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6548-RJ-21

2.90 A@42 V

48-port 10/100TX RJ-21

CEF256

With Supervisor Engine 720:

dCEF256 with WS-F6K-DFC3BXL (adds 1.47 A@42 V)

dCEF256 with WS-F6K-DFC3B (adds 1.67 A@42 V)

dCEF256 with WS-F6K-DFC3A (adds 2.57 A@42 V)

With Supervisor Engine 2, dCEF256 with WS-F6K-DFC (adds 2.10 A@42 V)

QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t

Number of ports: 48
Number of port groups: 1
Port ranges per port group: 1-48

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6148X2-RJ-45
WS-X6148X2-45AF

2.65 A@42 V
2.92 A@42 V

96-port 10/100TX RJ-45

QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t

WS-X6148X2-RJ-45 supports WS-F6K-FE48X2-AF

WS-X6148X2-45AF has WS-F6K-FE48X2-AF

 

With Supervisor Engine 720

12.2(18)SXF3

With Supervisor Engine 32

12.2(18)SXF3

With Supervisor Engine 2

12.2(18)SXF3

WS-X6196-RJ-21
WS-X6196-21AF

2.74 A@42 V
3.16 A@42 V

96-port 10/100TX RJ-21

QoS port architecture (Rx/Tx): 1p1q0t/1p3q1t

WS-X6196-RJ-21 supports WS-F6K-FE48X2-AF

WS-X6196-21AF has WS-F6K-FE48X2-AF

 

With Supervisor Engine 720

12.2(18)SXF3

With Supervisor Engine 32

12.2(18)SXF3

With Supervisor Engine 2

12.2(18)SXF3

WS-X6348-RJ-45
WS-X6348-RJ-45V

2.39 A@42 V
2.39 A@42 V

48-port 10/100TX RJ-45

128-KB per-port packet buffers

QoS port architecture (Rx/Tx): 1q4t/2q2t

WS-X6348-RJ-45 supports WS-F6K-VPWR

WS-X6348-RJ-45V has WS-F6K-VPWR

Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6348-RJ-21V

2.39 A@42 V

48-port 10/100TX RJ-21

128-KB per-port packet buffers

QoS port architecture (Rx/Tx): 1q4t/2q2t

Has WS-F6K-VPWR

Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6248-RJ-45

2.69 A@42 V

48-port 10/100TX RJ-45

QoS port architecture (Rx/Tx): 1q4t/2q2t

Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6248A-TEL

2.69 A@42 V

48-port 10/100TX RJ-21

128-KB per-port packet buffers

QoS port architecture (Rx/Tx): 1q4t/2q2t

Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6248-TEL

2.69 A@42 V

48-port 10/100TX RJ-21

QoS port architecture (Rx/Tx): 1q4t/2q2t

Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-X6148A-RJ-45
WS-X6148A-45AF

2.39 A@42 V
2.57 A@42 V

48-port 10/100TX RJ-45

128-KB per-port packet buffers

QoS port architecture (Rx/Tx): 1p1q4t/1p3q8t

WS-X6148A-RJ-45 supports WS-F6K-FE48-AF

WS-X6148A-45AF has WS-F6K-FE48-AF

Number of ports: 48
Number of port groups: 6
Port ranges per port group: 1-8, 9-16, 17-24, 25-32, 33-40, 41-48

 

With Supervisor Engine 720

12.2(18)SXF

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(18)SXF2

WS-X6148-RJ-45
WS-X6148-RJ-45V
WS-X6148-45AF

2.39 A@42 V
2.39 A@42 V
2.57 A@42 V

48-port 10/100TX RJ-45

128-KB per-port packet buffers

QoS port architecture (Rx/Tx): 1q4t/2q2t

WS-X6148-RJ-45 supports WS-F6K-VPWR and WS-F6K-FE48-AF

WS-X6148-RJ-45V has WS-F6K-VPWR

WS-X6148-45AF has WS-F6K-FE48-AF

Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48

 

With Supervisor Engine 720
(except with WS-F6K-FE48-AF)

12.2(14)SX

WS-F6K-FE48-AF with Supervisor Engine 720

12.2(17d)SXB

With Supervisor Engine 32

12.2(18)SXF

WS-F6K-FE48-AF with Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-F6K-FE48-AF with Supervisor Engine 2

12.2(17d)SXB

WS-X6148-RJ-21
WS-X6148-RJ-21V
WS-X6148-21AF

2.39 A@42 V
2.39 A@42 V
2.57 A@42 V

48-port 10/100TX RJ-21

128-KB per-port packet buffers

QoS port architecture (Rx/Tx): 1q4t/2q2t

WS-X6148-RJ-21 supports WS-F6K-VPWR and WS-F6K-FE48-AF

WS-X6148-RJ-21V has WS-F6K-VPWR

WS-X6148-21AF has WS-F6K-FE48-AF

Number of ports: 48
Number of port groups: 4
Port ranges per port group: 1-12, 13-24, 25-36, 37-48

 

With Supervisor Engine 720
(except WS-F6K-FE48-AF)

12.2(14)SX

WS-F6K-FE48-AF with Supervisor Engine 720

12.2(17d)SXB

With Supervisor Engine 32

12.2(18)SXF

WS-F6K-FE48-AF with Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-F6K-FE48-AF with Supervisor Engine 2

12.2(17d)SXB


Ethernet Switching Modules

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6024-10FL-MT

1.52 A@42 V

24-port 10BASE-FL MT-RJ

QoS port architecture (Rx/Tx): 1q4t/2q2t

Number of ports: 24
Number of port groups: 2
Port ranges per port group: 1-12, 13-24

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB


Optical Services Modules (OSMs)

OSM Guidelines and Restrictions

Gigabit Ethernet WAN

OC-48 Packet over SONET

OC-48 DPT/Packet over SONET

OC-12 Packet over SONET

OC-3 Packet over SONET

OC-12 Channelized

CT3/T1 Channelized/Unchannelized

OC-12 ATM

OSM Guidelines and Restrictions

Cisco IOS Software modularity does not support OSMs.

Supervisor Engine 32 does not support OSMs.

With Release 12.2(18)SXD and later releases, OSMs require a minimum of 128 MB of dynamic random-access memory (SDRAM)—See this publication for memory upgrade procedures:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/hardware/osmodule/app_upgr.htm

OSMs are CEF256 modules.

OSM WAN port numbering starts with 1.

On OSMs with Gigabit Ethernet GBIC Layer 2 LAN ports:

OSM LAN port numbering starts with 1.

The LAN ports are in a single port group.

In releases earlier than Release 12.2(18)SXD1, WS-SVC-WLAN-1-K9 has not been tested with OSMs.

The OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs have been tested with the service modules and WS-SUP720.

In releases earlier than Release 12.2(18)SXD1, except for the OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs, the following service modules have not been tested with other OSMs:

WS-X6066-SLB-APC content switching module (CSM)

WS-SVC-IDSM2-K9 intrusion detection system module

WS-SVC-NAM-2 and WS-SVC-NAM-1 network analysis modules (NAMs)

WS-SVC-SSL-1 SSL services module

Gigabit Ethernet WAN

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
OSM-4GE-WAN-GBIC

3.59 A@42 V

4-port Gigabit Ethernet WAN (GBIC); CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-2+4GE-WAN+

5.08 A@42 V

4-port Gigabit Ethernet WAN (GBIC) with two Layer 2 LAN ports; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB


OC-48 Packet over SONET


Note Also has four Layer 2 LAN ports.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
OSM-1OC48-POS-SS
OSM-1OC48-POS-SI
OSM-1OC48-POS-SL

4.25 A@42 V

1-port OC-48/STM-16 SONET/SDH OSM, SM-SR; CEF256
1-port OC-48/STM-16 SONET/SDH OSM, SM-IR; CEF256
1-port OC-48/STM-16 SONET/SDH OSM, SM-LR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-1OC48-POS-SI+
OSM-1OC48-POS-SL+
OSM-1OC48-POS-SS+

3.90 A@42 V

Enhanced 1-port OC-48/STM-16 SONET/SDH OSM, SM-IR; CEF256
Enhanced 1-port OC-48/STM-16 SONET/SDH OSM, SM-LR; CEF256
Enhanced 1-port OC-48/STM-16 SONET/SDH OSM, SM-SR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB


OC-48 DPT/Packet over SONET


Note Also has four Layer 2 LAN ports.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
OSM-2OC48/1DPT-SS
OSM-2OC48/1DPT-SI
OSM-2OC48/1DPT-SL

5.75 A@42 V

2-port OC-48 DPT/POS, SM-SR; CEF256
2-port OC-48 DPT/POS, SM-IR; CEF256
2-port OC-48 DPT/POS, SM-LR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB


OC-12 Packet over SONET


Note Also has four Layer 2 LAN ports.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
OSM-4OC12-POS-MM
OSM-4OC12-POS-SI
OSM-4OC12-POS-SL

4.78 A@42 V

4-port OC-12c/STM-4c POS, MM; CEF256
4-port OC-12c/STM-4c POS, SM-IR; CEF256
4-port OC-12c/STM-4c POS, SM-LR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-4OC12-POS-SI+

4.55 A@42 V

Enhanced 4-port OC-12c/STM-4c POS, SM-IR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-2OC12-POS-MM+
OSM-2OC12-POS-MM
OSM-2OC12-POS-SI
OSM-2OC12-POS-SL

3.36 A@42 V

2-port OC-12c/STM-4c POS, MM; CEF256
2-port OC-12c/STM-4c POS, MM; CEF256
2-port OC-12c/STM-4c POS, SM-IR; CEF256
2-port OC-12c/STM-4c POS, SM-LR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-2OC12-POS-SI+

3.36 A@42 V

Enhanced 2-port OC-12c/STM-4c POS, SM-IR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB


OC-3 Packet over SONET


Note Also has four Layer 2 LAN ports.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
OSM-16OC3-POS-MM
OSM-16OC3-POS-SI
OSM-16OC3-POS-SL

5.09 A@42 V

16-port OC-3c/STM-1c POS, MM; CEF256
16-port OC-3c/STM-1c POS, SM-IR; CEF256
16-port OC-3c/STM-1c POS, SM-LR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-16OC3-POS-SI+

4.80 A@42 V

Enhanced 16-port OC-3c/STM-1c POS, SM-IR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-8OC3-POS-MM
OSM-8OC3-POS-SI
OSM-8OC3-POS-SL

3.57 A@42 V

8-port OC-3c/STM-1c POS, MM; CEF256
8-port OC-3c/STM-1c POS, SM-IR; CEF256
8-port OC-3c/STM-1c POS, SM-LR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-8OC3-POS-SI+
OSM-8OC3-POS-SL+

3.57 A@42 V

Enhanced 8-port OC-3c/STM-1c POS, SM-IR; CEF256
Enhanced 8-port OC-3c/STM-1c POS, SM-LR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-4OC3-POS-SI

2.44 A@42 V

4-port OC-3c/STM-1c POS, SM-IR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-4OC3-POS-SI+

2.44 A@42 V

Enhanced 4-port OC-3c/STM-1c POS, SM-IR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB


OC-12 Channelized


Note Also has four Layer 2 LAN ports.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
OSM-1CHOC12/T3-SI
OSM-1CHOC12/T1-SI

4.40 A@42 V
2.80 A@42 V

1-port channelized OC-12, SM-IR; CEF256
1-port channelized OC-12, SM-IR; CEF256

 
 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB


CT3/T1 Channelized/Unchannelized


Note OSM-12CT3/T1 has mini-SMB connectors for use with 75-Ohm copper coax cable.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
OSM-12CT3/T1

2.80 A@42 V

12-port channelized/unchannelized CT3/T1; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB


OC-12 ATM


Note Also has four Layer 2 LAN ports.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
OSM-2OC12-ATM-MM
OSM-2OC12-ATM-SI

3.62 A@42 V

2-port OC-12/STM-4 ATM OSM, MM; CEF256
2-port OC-12/STM-4 ATM OSM, SM-IR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

OSM-2OC12-ATM-MM+
OSM-2OC12-ATM-SI+

4.00 A@42 V

Enhanced 2-port OC-12/STM-4 ATM OSM, MM; CEF256
Enhanced 2-port OC-12/STM-4 ATM OSM, SM-IR; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB


Shared Port Adapter (SPA) Interface Processors (SIPs)


NoteSee the "FPD Image Packages" section for information about additional procedures required to support SIPs with Release 12.2(18)SXE and later releases.

7600-SIP-400 and 7600-SIP-600 are not supported in PFC3A mode.

Cisco IOS Software modularity does not support SIPs.


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
7600-SIP-600

8.14 A@42 V

SPA Interface Processor-600

Note 7600-SIP-600 has a WS-F6700-DFC3BXL.

Supported only with Supervisor Engine 720

12.2(18)SXF

Note Supervisor Engine 32 does not support 7600-SIP-600.

7600-SIP-400

6.31 A@42 V

SPA Interface Processor-400

With Supervisor Engine 720

12.2(18)SXE

With Supervisor Engine 32

12.2(18)SXF

7600-SIP-200

5.72 A@42 V

SPA Interface Processor-200

With Supervisor Engine 720

12.2(18)SXE

With Supervisor Engine 32

12.2(18)SXF


Shared Port Adapters (SPAs)

These sections describe SPAs:

Ethernet SPAs

POS SPAs

ATM SPAs

SFPs for OC3 and OC12 POS and ATM SPAs

Serial SPAs


Note Cisco IOS Software modularity does not support SPAs.


Ethernet SPAs

These sections describe Ethernet SPAs:

10-Gigabit Ethernet SPAs

Gigabit Ethernet SPAs

10-Gigabit Ethernet SPAs

Product ID
(append "=" for spares)
SIP Support
Product Description
Minimum Software Version
SPA-1XTENGE-XFP

7600-SIP-600

1-port 10-Gigabit Ethernet SPA, LANPHY XFP Optics

12.2(18)SXF

XFP Modules Supported in SPA-1XTENGE-XFP
 XFP-10GLR-OC192LR

10-Gigabit Ethernet LR (10 km)


Gigabit Ethernet SPAs

Product ID
(append "=" for spares)
SIP Support
Product Description
Minimum Software Version
SPA-10X1GE

7600-SIP-600

10-port Gigabit Ethernet SPA, SFP Optics

12.2(18)SXF

SPA-5X1GE

7600-SIP-600

5-port Gigabit Ethernet SPA, SFP Optics

12.2(18)SXF

SPA-2X1GE

7600-SIP-400

2-port Gigabit Ethernet SPA, SFP Optics

12.2(18)SXF

SFPs Supported in Gigabit Ethernet SPAs
 SFP-GE-S

Extended Temperature SX SFP

 SFP-GE-L

Extended Temperature LX/LH SFP

 SFP-GE-Z

Extended Temperature ZX SFP


POS SPAs

Product ID
(append "=" for spares)
SIP Support
Product Description
Minimum Software Version
SPA-OC192POS-VSR

7600-SIP-600

1-port OC-192c/STM-64 POS/RPR SPA, VSR-1

12.2(18)SXF2

SPA-2XOC3-POS

7600-SIP-200
7600-SIP-400

2-port OC-3c/STM-1c POS SPA

Note Requires SFPs.

12.2(18)SXE

SPA-4XOC3-POS

7600-SIP-200
7600-SIP-400

4-port OC-3c/STM-1c POS SPA

Note Requires SFPs.

12.2(18)SXE

SPA-1XOC12-POS

7600-SIP-400

1-port OC-12c/STM-4c POS SPA

Note Requires an SFP.

12.2(18)SXE

SPA-OC192POS-LR

7600-SIP-600

1-port OC-192c/STM-64 POS/RPR SPA, SM-LR

12.2(18)SXF

SPA-OC192POS-XFP

7600-SIP-600

1-port OC-192c/STM-64 POS/RPR SPA, XFP Optics

12.2(18)SXF

XFP Modules Supported in SPA-OC192POS-XFP

XFP-10GLR-OC192SR Single-Mode (SM) Short Reach (SR)

XFP-10GER-OC192IR Single-Mode (SM) Intermediate Reach (IR-2)

SPA-OC192POS-VSR

7600-SIP-600

1-port OC-192c/STM-64 POS/RPR SPA, VSR-1

12.2(18)SXF1


ATM SPAs

Product ID
(append "=" for spares)
SIP Support
Product Description
Minimum Software Version
SPA-2XOC3-ATM

7600-SIP-200
7600-SIP-400

2-port OC-3c/STM-1c ATM SPA

Note Requires SFPs.

12.2(18)SXE

SPA-4XOC3-ATM

7600-SIP-200
7600-SIP-400

4-port OC-3c/STM-1c ATM SPA

Note Requires SFPs.

12.2(18)SXE

SPA-1XOC12-ATM

7600-SIP-400

1-Port OC-12c/STM-4c ATM SPA

Note Requires an SFP.

12.2(18)SXE

SPA-1XOC48-ATM

7600-SIP-400

1 port OC-48c/STM-16 ATM SPA

12.2(18)SXF


SFPs for OC3 and OC12 POS and ATM SPAs

Product ID
(append "=" for spares)
Product Description
SFP-OC3-MM

OC-3/STM-1 pluggable short-reach (2 km) transceiver module, 1310-nm wavelength, MMF, LC connector

SFP-OC3-SR

OC-3/STM-1 pluggable short-reach (2 km) transceiver module, 1310-nm wavelength, LC connector

SFP-OC3-IR1

OC-3/STM-1 pluggable intermediate-reach (15 km) transceiver module, 1310-nm wavelength, LC connector

SFP-OC3-LR1

OC-3/STM-1 pluggable long-reach (40 km) transceiver module, 1310-nm wavelength, LC connector

SFP-OC3-LR2

OC-3/STM-1 pluggable long-reach (80 km) transceiver module, 1550-nm wavelength, LC connector

SFP-OC12-MM

OC-12/STM-4 pluggable short-reach (2 km) transceiver module, 1310-nm wavelength, MMF, LC connector

SFP-OC12-SR

OC-12/STM-4 pluggable short-reach (2 km) transceiver module, 1310-nm wavelength, LC connector

SFP-OC12-IR1

OC-12/STM-4 pluggable intermediate-reach (15 km) transceiver module, 1310-nm wavelength

SFP-OC12-LR1

OC-12/STM-4 pluggable long-reach (40 km) transceiver module, 1310-nm wavelength, LC connector

SFP-OC12-LR2

OC-12/STM-4 pluggable long-reach (80 km) transceiver module, 1550-nm wavelength, LC connector


Serial SPAs

Product ID
(append "=" for spares)
SIP Support
Product Description
Minimum Software Version
SPA-8XCHT1/E1

7600-SIP-200

8-Port Channelized T1/E1 SPA

12.2(18)SXE

SPA-2XT3/E3

7600-SIP-200

2-port Clear Channel T3/E3 SPA

12.2(18)SXE

SPA-4XT3/E3

7600-SIP-200

4-port Clear Channel T3/E3 SPA

12.2(18)SXE

SPA-2XCT3/DS0

7600-SIP-200

2-port Channelized T3 to DS0 SPA

12.2(18)SXE

SPA-4XCT3/DS0

7600-SIP-200

4-port Channelized T3 to DS0 SPA

12.2(18)SXE


Services SPA Carrier (SSC)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
7600-SSC-400

5.43 A@42 V

Services SPA Carrier (SSC)

With Supervisor Engine 720

12.2(18)SXE

With Supervisor Engine 32

12.2(18)SXF2

Note 7600-SSC-400 does not maintain state when an NSF with SSO redundancy mode switchover occurs.


Services SPAs


Note See the "FPD Image Packages" section for information about additional procedures required to support SPA-IPSEC-2G with Release 12.2(18)SXE and later releases.


Product ID
(append "=" for spares)
Carrier
Product Description
Minimum Software Version
SPA-IPSEC-2G

7600-SSC-400

IPsec SPA

12.2(18)SXE2

Note SPA-IPSEC-2G does not support TACACS+ authentication for IPsec. (CSCee33200)


FlexWAN and Enhanced FlexWAN Modules


NoteIn releases earlier than Release 12.2(18)SXD1, WS-SVC-WLAN-1-K9 has not been tested with the FlexWAN or Enhanced FlexWAN modules.

The following service modules have not been tested with the Enhanced FlexWAN module and Release 12.2(17b)SXA, Release 12.2(17b)SXA2, or Release 12.2(17d)SXB:

WS-X6066-SLB-APC content switching module (CSM)

WS-SVC-IDSM2-K9 intrusion detection system module

WS-SVC-NAM-2 and WS-SVC-NAM-1 network analysis modules (NAMs)

WS-SVC-SSL-1 SSL services module


Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6582-2PA

2.50 A@42 V

Enhanced FlexWAN Module; CEF256

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

Note See the "FPD Image Packages" section for information about additional procedures required to support WS-X6582-2PA with Release 12.2(18)SXE and later releases.

WS-X6182-2PA

2.38 A@42 V

FlexWAN Module

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 2

12.2(17d)SXB

Note Supervisor Engine 32 does not support WS-X6182-2PA.


FlexWAN and Enhanced FlexWAN Module Port Adapters

Product ID
(append "=" for spares)
Product Description
Minimum Software Version
PA-2FE

2-port Fast Ethernet Port Adapter (supported only in WS-X6582-2PA)

12.2(18)SXE

PA-1FE

1-port Fast Ethernet Port Adapter (supported only in WS-X6582-2PA)

12.2(18)SXE

PA-POS-1OC3

1-port Packet over SONET OC3c/STM1 Port Adapter

12.2(18)SXE

PA-POS-2OC3

2-port POS OC3c/STM1

12.2(17b)SXA

SFPs for PA-POS-2OC3
 SFP-OC3-MM

Short range, multimode fiber

12.2(17b)SXA

 SFP-OC3-IR1

Intermediate range, single-mode fiber

12.2(17b)SXA

 SFP-OC3-LR1

Long range, single-mode fiber

12.2(17b)SXA

PA-POS-OC3MM
PA-POS-OC3SMI
PA-POS-OC3SML

Packet over SONET (OC-3)

12.2(14)SX

PA-A6-OC3MM

1-port ATM OC-3c/STM-1 multimode port adapter, enhanced

12.2(14)SX

PA-A6-OC3SMI

1-port ATM OC-3c/STM-1 single-mode (IR) port adapter, enhanced

12.2(14)SX

PA-A6-OC3SML

1-port ATM OC-3c/STM-1 single-mode (LR) port adapter, enhanced

12.2(14)SX

PA-A6-T3

1-port ATM DS3 port adapter, enhanced

12.2(14)SX

PA-A6-E3

1-port ATM E3 port adapter, enhanced

12.2(14)SX

PA-A3-OC3MM
PA-A3-OC3SMI
PA-A3-T3
PA-A3-OC3SML
PA-A3-E3
PA-A3-8T1IMA
PA-A3-8E1IMA

ATM with traffic shaping

Note These port adapters do not support LANE when installed in the FlexWAN module.

12.2(14)SX

PA-T3
PA-T3+
PA-2T3
PA-2T3+
PA-E3
PA-2E3
PA-MC-T3
PA-MC-E3
PA-MC-2T3+

T3/E3 (clear-channel and channelized)

12.2(14)SX

PA-4T+
PA-8T-V35
PA-8T-X21
PA-8T-232
PA-MC-2E1/120
PA-MC-8T1
PA-MC-8E1/120
PA-MC-2T1
PA-MC-4T1

T1/E1

12.2(14)SX

PA-4E1G/75
PA-4E1G/120

T1/E1

12.2(17)SX

PA-MC-8TE1+

Multichannel T1/E1 8PRI

Note This port adapter does not support ISDN PRI when installed in the FlexWAN module.

12.2(14)SX

PA-H
PA-2H

HSSI

12.2(14)SX

PA-MC-STM-1

Multichannel STM-1

12.2(14)SX


Service Modules


Note For any service modules that runs its own software, see the service module software release notes for information about the minimum required service module software version.


Application Control Engine (ACE) Module

Wireless Services Module (WiSM)

Application-Oriented Networking Module

WebVPN Services Module

Anomaly Guard Module

Traffic Anomaly Detector Module

Wireless LAN Service Module (WLSM)

Persistent Storage Device (PSD) Module

Multi-Processor WAN Application Module (MWAM)

Content Services Gateway (CSG) Module

Communication Media Module (CMM)

IPsec VPN Acceleration Services Module

Content Switching Module with SSL (CSM-S)

Content Switching Module (CSM)

Firewall Services Module

Intrusion Detection System Modules (IDSMs)

Network Analysis Modules (NAMs)

Secure Sockets Layer (SSL) Services Module

Application Control Engine (ACE) Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Versions
ACE10-6500-K9

5.23 A@42 V

Application Control Engine (ACE) module

 

With Supervisor Engine 720

12.2(18)SXF4

ACE10-6500-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/ace/index.htm

See the ACE10-6500-K9 software release notes for information about the minimum required ACE10-6500-K9 software version.

Note

Cisco IOS Software modularity does not support ACE10-6500-K9.

Supervisor Engine 32 does not support ACE10-6500-K9.

Supervisor Engine 2 does not support ACE10-6500-K9.


Wireless Services Module (WiSM)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Versions
WS-SVC-WISM-1-K9

6.07 A@42 V

Wireless Services Module (WiSM)

 

With Supervisor Engine 720

12.2(18)SXF2

WS-SVC-WISM-1-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/wireless/control/c44/index.htm

See the WS-SVC-WISM-1-K9 software release notes for information about the minimum required WS-SVC-WISM-1-K9 software version.

Note

In Release 12.2(18)SXF4, Cisco IOS Software modularity does not support WS-SVC-WISM-1-K9.

Supervisor Engine 32 does not support WS-SVC-WISM-1-K9.

Supervisor Engine 2 does not support WS-SVC-WISM-1-K9.


Application-Oriented Networking Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Versions
WS-SVC-AON-1-K9

4.00 A@42 V

Application-Oriented Networking (AON) Module

 

With Supervisor Engine 720

12.2(18)SXE1

WS-SVC-AON-1-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/aon/index.htm

See the WS-SVC-AON-1-K9 software release notes for information about the minimum required WS-SVC-AON-1-K9 software version.

Note

Cisco IOS Software modularity does not support WS-SVC-AON-1-K9.

Supervisor Engine 32 does not support WS-SVC-AON-1-K9.

Supervisor Engine 2 does not support WS-SVC-AON-1-K9.


WebVPN Services Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Versions
WS-SVC-WEBVPN-K9

2.94 A@42 V

WebVPN Services Module

 

With Supervisor Engine 720

12.2(18)SXE2
12.2(17d)SXB7

With Supervisor Engine 32

12.2(18)SXF

WS-SVC-WEBVPN-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/webvpn/index.htm

See the WS-SVC-WEBVPN-K software release notes for information about the minimum required WS-SVC-WEBVPN-K software version.

Note

Cisco IOS Software modularity does not support WS-SVC-WEBVPN-K9.

Supervisor Engine 2 does not support WS-SVC-WEBVPN-K9.


Anomaly Guard Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-AGM-1-K9

4.00 A@42 V

Anomaly Guard Module

 

With Supervisor Engine 720

12.2(18)SXD3

With Supervisor Engine 2

12.2(18)SXD3

WS-SVC-AGM-1-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/secure/ad_g/index.htm

See the WS-SVC-AGM-1-K9 software release notes for information about the minimum required WS-SVC-AGM-1-K9 software version.

Note

Cisco IOS Software modularity does not support WS-SVC-AGM-1-K9.

Supervisor Engine 32 does not support WS-SVC-AGM-1-K9.

In Release 12.2(18)SXD3 and rebuilds, WS-SVC-AGM-1-K9 has not been tested with OSMs or FlexWAN modules.


Traffic Anomaly Detector Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-ADM-1-K9

4.00 A@42 V

Traffic Anomaly Detector Module

 

With Supervisor Engine 720

12.2(18)SXD3

With Supervisor Engine 2

12.2(18)SXD3

WS-SVC-ADM-1-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/secure/ad_g/index.htm

See the WS-SVC-ADM-1-K9 software release notes for information about the minimum required WS-SVC-ADM-1-K9 software version.

Note

Cisco IOS Software modularity does not support WS-SVC-ADM-1-K9.

Supervisor Engine 32 does not support WS-SVC-ADM-1-K9.

In Release 12.2(18)SXD3 and rebuilds, WS-SVC-ADM-1-K9 has not been tested with OSMs or FlexWAN modules.


Wireless LAN Service Module (WLSM)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-WLAN-1-K9

3.10 A@42 V

Wireless LAN service module

 

With Supervisor Engine 720

12.2(18)SXD

WS-SVC-WLAN-1-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/wlsm/index.htm

See the WS-SVC-WLAN-1-K9 software release notes for information about the minimum required WS-SVC-WLAN-1-K9 software version.

Note

Cisco IOS Software modularity does not support WS-SVC-WLAN-1-K9.

Supervisor Engine 32 does not support WS-SVC-WLAN-1-K9.

Supervisor Engine 2 does not support WS-SVC-WLAN-1-K9.

In releases earlier than Release 12.2(18)SXD1, WS-SVC-WLAN-1-K9 has not been tested with OSMs or FlexWAN modules.


Persistent Storage Device (PSD) Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-PSD-1

4.00 A@42 V

Persistent Storage Device Module

   

With Supervisor Engine 720

12.2(18)SXD1

   

With Supervisor Engine 2

12.2(17d)SXB

WS-SVC-PSD-1 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/psd/index.htm

See the WS-SVC-PSD-1 software release notes for information about the minimum required WS-SVC-PSD-1 software version.

Note

Cisco IOS Software modularity does not support WS-SVC-PSD-1.

Supervisor Engine 32 does not support WS-SVC-PSD-1.

With Release 12.2(18)SXD1 and later, WS-SVC-PSD-1 maintains state when an NSF with SSO redundancy mode switchover occurs.


Multi-Processor WAN Application Module (MWAM)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-MWAM-1

3.57 A@42 V

Multi-Processor WAN Application Module

 

With Supervisor Engine 720

12.2(18)SXD1

With Supervisor Engine 32

12.2(18)SXF5

With Supervisor Engine 2

12.2(17d)SXB

WS-SVC-MWAM-1 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/mwam/index.htm

See the WS-SVC-MWAM-1 software release notes for information about the minimum required WS-SVC-MWAM-1 software version.

Note

Cisco IOS Software modularity does not support WS-SVC-MWAM-1.

With Release 12.2(18)SXD1 and later releases, WS-SVC-MWAM-1 maintains state when an NSF with SSO redundancy mode switchover occurs.

With Releases earlier than Release 12.2(18)SXD1, WS-SVC-MWAM-1 does not maintain state when an NSF with SSO redundancy mode switchover occurs.


Content Services Gateway (CSG) Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-CSG-1

3.00 A@42 V

Content Services Gateway (CSG) Module

 

With Supervisor Engine 720

12.2(18)SXD1

With Supervisor Engine 2

12.2(17d)SXB

WS-SVC-CSG-1 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/wireless/moblwrls/csg/index.htm

See the WS-SVC-CSG-1 software release notes for information about the minimum required WS-SVC-CSG-1 software version.

Note

Cisco IOS Software modularity does not support WS-SVC-CSG-1.

Supervisor Engine 32 does not support WS-SVC-CSG-1.


Communication Media Module (CMM)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-CMM

6.00 A@42 V

Communication Media Module

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 2

12.2(17d)SXB

WS-SVC-CMM runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/cmm/index.htm

See the WS-SVC-CMM software release notes for information about the minimum required WS-SVC-CMM software version.

Note

Cisco IOS Software modularity does not support WS-SVC-CMM.

Supervisor Engine 32 does not support WS-SVC-CMM.

Communication Media Module Port Adapters
 WS-SVC-CMM-6E1

6-Port E1 Interface Port Adapter

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 2

12.2(17d)SXB

 WS-SVC-CMM-6T1

6-Port T1 Interface Port Adapter

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 2

12.2(17d)SXB

 WS-SVC-CMM-ACT

Adhoc Conferencing and Transcoding Port Adapter

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 2

12.2(17d)SXB

 WS-SVC-CMM-24FXS

24-Port FXS Interface Port Adapter

 

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 2

12.2(17d)SXB


IPsec VPN Acceleration Services Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-IPSEC-1

1.89 A@42 V

IPsec VPN Acceleration Services Module

 

With Supervisor Engine 720

12.2(17b)SXA

With Supervisor Engine 2

12.2(17d)SXB

WS-SVC-IPSEC-1 uses the Cisco IOS software that is running on the supervisor engine and MSFC—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_14459.htm

Note

Cisco IOS Software modularity does not support WS-SVC-IPSEC-1.

Supervisor Engine 32 does not support WS-SVC-IPSEC-1.

With Release 12.2(18)SXE and later releases, WS-SVC-IPSEC-1 requires an advanced services image (see the "Feature Sets" section).

With releases earlier than Release 12.2(18)SXE, WS-SVC-IPSEC-1 requires a k9 image (see the "Feature Sets" section).

WS-SVC-IPSEC-1 does not support TACACS+ authentication for IPsec. (CSCee33200)

WS-SVC-IPSEC-1 does not maintain state when an NSF with SSO redundancy mode switchover occurs.

WS-SVC-IPSEC-1 does not maintain state when a single router mode with stateful switchover ( SRM with SSO) redundancy mode switchover occurs.

In releases earlier than Release 12.2(18)SXD1, WS-SVC-IPSEC-1 has not been tested with OSM-1CHOC12/T1-SI or OSM-12CT3/T1.

To avoid reloads with software releases where caveat CSCed17605 is not resolved (CSCed17605 is resolved in Release 12.2(17d)SXB and later releases), do not configure the single router mode with stateful switchover ( SRM with SSO) redundancy mode with a WS-SVC-IPSEC-1 module installed. In software releases where caveat CSCed17605 is not resolved, the WS-SVC-IPSEC-1 module does not maintain state when an SRM with SSO redundancy mode switchover occurs.


Content Switching Module with SSL (CSM-S)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6066-SLB-S-K9

2.15 A@42 V

Content Switching Module with SSL (CSM-S)

 

With Supervisor Engine 720

12.2(18)SXE

With Supervisor Engine 2

12.2(18)SXD

WS-X6066-SLB-S-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/csm/index.htm

See the WS-X6066-SLB-S-K9 software release notes for information about the minimum required WS-X6066-SLB-S-K9 software version.

Note

Cisco IOS Software modularity does not support WS-X6066-SLB-S-K9.

Supervisor Engine 32 does not support WS-X6066-SLB-S-K9.

With Release 12.2(18)SXD1 and later releases, WS-X6066-SLB-S-K9 maintains state when an NSF with SSO redundancy mode switchover occurs.

WS-X6066-SLB-S-K9 does not maintain state when a single router mode with stateful switchover ( SRM with SSO) redundancy mode switchover occurs.

The OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs have been tested with the WS-X6066-SLB-S-K9 content switching module.

In releases earlier than Release 12.2(18)SXD1, the WS-X6066-SLB-S-K9 content switching module has not been tested with other OSMs or the Enhanced FlexWAN module.


Content Switching Module (CSM)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-X6066-SLB-APC

3.00 A@42 V

Content Switching Module

 

With Supervisor Engine 720

12.2(14)SX1

With Supervisor Engine 2

12.2(17d)SXB

WS-X6066-SLB-APC runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/csm/index.htm

See the WS-X6066-SLB-APC software release notes for information about the minimum required WS-X6066-SLB-APC software version.

Note

Supervisor Engine 32 does not support WS-X6066-SLB-APC.

With Release 12.2(18)SXD1 and later releases, WS-X6066-SLB-APC maintains state when an NSF with SSO redundancy mode switchover occurs.

WS-X6066-SLB-APC does not maintain state when a single router mode with stateful switchover ( SRM with SSO) redundancy mode switchover occurs.

The OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs have been tested with the WS-X6066-SLB-APC content switching module and WS-SUP720.

In releases earlier than Release 12.2(18)SXD1, WS-X6066-SLB-APC has not been tested with other OSMs or the Enhanced FlexWAN module.


Firewall Services Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-FWM-1-K9

4.09 A@42 V

Firewall Services Module; CEF256

 

With Supervisor Engine 720

12.2(14)SX1

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-SVC-FWM-1-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/fwsm/index.htm

See the WS-SVC-FWM-1-K9 software release notes for information about the minimum required WS-SVC-FWM-1-K9 software version.

Note

With Release 12.2(18)SXD3 and later Cisco IOS releases and with Firewall Services Module Software Release 2.3(1), WS-SVC-FWM-1-K9 maintains state when an NSF with SSO redundancy mode switchover occurs.

WS-SVC-FWM-1-K9 does not maintain state when a single router mode with stateful switchover ( SRM with SSO) redundancy mode switchover occurs.


Intrusion Detection System Modules (IDSMs)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-IDSM2-K9

2.50 A@42 V

Intrusion Detection System Module 2; CEF256

 

With Supervisor Engine 720

12.2(14)SX1

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-SVC-IDSM2-K9 runs its own software—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/iaabu/csids/index.htm

See the WS-SVC-IDSM2-K9 software release notes for information about the minimum required WS-SVC-IDSM2-K9 software version.

Note

WS-SVC-IDSM2-K9 has been tested with OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs.

In releases earlier than Release 12.2(18)SXD1, WS-SVC-IDSM2-K9 has not been tested with other OSMs or the Enhanced FlexWAN module.


Network Analysis Modules (NAMs)

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-NAM-2

3.47 A@42 V

Network Analysis Module 2; CEF256

WS-SVC-NAM-1

2.89 A@42 V

Network Analysis Module 1; CEF256

 

With Supervisor Engine 720

12.2(14)SX1

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-SVC-NAM-2 and WS-SVC-NAM-1 run their own software—See this publication for more information:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/fam_mod/svc_namx/index.htm

See the WS-SVC-NAM-2 and WS-SVC-NAM-1 software release notes for information about the minimum required WS-SVC-NAM-2 and WS-SVC-NAM-1 software version.

Note

With Release 12.2(17b)SXA and rebuilds and Release 12.2(17d)SXB and rebuilds, WS-SVC-NAM-2 and WS-SVC-NAM-1 support single router mode with stateful switchover ( SRM with SSO) redundancy mode.

WS-SVC-NAM-2 and WS-SVC-NAM-1 have been tested with OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs.

In releases earlier than Release 12.2(18)SXD1, WS-SVC-NAM-2 and WS-SVC-NAM-1 have not been tested with other OSMs or the Enhanced FlexWAN module.


Secure Sockets Layer (SSL) Services Module

Product ID
(append "=" for spares)
Power
Required
Product Description
Minimum Software Version
WS-SVC-SSL-1

2.94 A@42 V

Secure Sockets Layer (SSL) Services Module

 

With Supervisor Engine 720

12.2(14)SX1

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-SVC-SSL-1 runs its own software—See this publication for more information:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/ssl_mod/index.htm

See the WS-SVC-SSL-1 software release notes for information about the minimum required WS-SVC-SSL-1 software version.

Note  

Cisco IOS Software modularity does not support WS-SVC-SSL-1.

WS-SVC-SSL-1 does not maintain state when an NSF with SSO redundancy mode switchover occurs.

WS-SVC-SSL-1 does not maintain state when a single router mode with stateful switchover ( SRM with SSO) redundancy mode switchover occurs.

WS-SVC-SSL-1 has been tested with OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs.

In releases earlier than Release 12.2(18)SXD1, WS-SVC-SSL-1 has not been tested with other OSMs or the Enhanced FlexWAN module.


Fan Trays

High-Capacity Fan Trays

Standard-Capacity Fan Trays


NoteThe fan trays required by the Supervisor Engine 720 are supported only with the power supplies listed in the " WS-C6503, WS-C6503-E, and CISCO7603 Power Supplies" and " All Other Power Supplies" sections.

Enter the show environment status | include fan command or the show environment cooling command to display information about the installed fan trays.

To use a high-capacity fan tray with a Supervisor Engine 2, you must enter the hw-module fan-tray version 2 command and then remove and quickly reinsert the fan tray.


High-Capacity Fan Trays

These high-capacity fan trays support both all supervisor engines.

Product ID
(append "=" for spares)
Power
Allocated at 42 V
Product Description
Minimum
Software
Version
WS-C6503-E-FAN

1.37 A@42 V

High-capacity fan tray for WS-C6503-E chassis

12.2(14)SX

Note In releases earlier than Release 12.2(18)SXD, WS-C6503-E-FAN requires the same power as FAN-MOD-3HS.

FAN-MOD-3HS

2.98 A@42 V

High-capacity fan tray for WS-C6503 and CISCO7603 chassis

12.2(14)SX

FAN-MOD-6HS

4.29 A@42 V

High-capacity fan tray for CISCO7606 chassis

12.2(14)SX

WS-C6506-E-FAN

2.35 A@42 V

High-capacity fan tray for WS-C6506-E chassis

12.2(14)SX

WS-C6K-6SLOT-FAN2

12 V fan

High-capacity fan tray for WS-C6506 chassis

12.2(14)SX

FAN-MOD-09

5.75 A@42 V

High-capacity fan tray for WS-C6509-NEB-A and CISCO7609 chassis

12.2(14)SX

WS-C6509-E-FAN

3.58 A@42 V

High-capacity fan tray for WS-C6509-E chassis

12.2(14)SX

WS-C6K-9SLOT-FAN2

12 V fan

High-capacity fan tray for WS-C6509 chassis

12.2(14)SX

WS-C6K-13SLT-FAN2

7.10 A@42 V

High-capacity fan tray for WS-C6513 and CISCO7613 chassis

12.2(14)SX


Standard-Capacity Fan Trays

These standard-capacity fan trays support only Supervisor Engine 2.

Product ID
(append "=" for spares)
Power
Allocated at 42 V
Product Description
Minimum
Software
Version
FAN-MOD-3

None

Standard-capacity fan tray for WS-C6503 and CISCO7603 chassis

12.2(17d)SXB

FAN-MOD-6

None

Standard-capacity fan tray for CISCO7606 chassis

12.2(17d)SXB

WS-C6K-6SLOT-FAN

12 V fan

Standard-capacity fan tray for WS-C6506 chassis

12.2(17d)SXB

WS-C6509-NEB-FAN

12 V fan

Standard fan tray for WS-C6509-NEB chassis

12.2(17d)SXB

WS-C6K-9SLOT-FAN

12 V fan

Standard-capacity fan tray for WS-C6509 chassis

12.2(17d)SXB

WS-C6K-13SLT-FAN

12 V fan

Standard-capacity fan tray for WS-C6513 and CISCO7613 chassis

12.2(17d)SXB


Power Supplies

CISCO7606 Power Supplies

WS-C6504-E and CISCO7604 Power Supplies

WS-C6503, WS-C6503-E, and CISCO7603 Power Supplies

All Other Power Supplies

CISCO7606 Power Supplies

Product ID
(append "=" for spares)
Product Description
Minimum Software Version
PWR-2700-AC

2700 W AC power supply

12.2(18)SXE

PWR-2700-DC

2700 W DC power supply

12.2(18)SXE


WS-C6504-E and CISCO7604 Power Supplies

Product ID
(append "=" for spares)
Product Description
Minimum Software Version
PWR-2700-DC/4

2700 W DC power supply

12.2(18)SXE


WS-C6503, WS-C6503-E, and CISCO7603 Power Supplies

Product ID
(append "=" for spares)
Product Description
Minimum Software Version
PWR-1400-AC

1,400 W AC power supply

12.2(17a)SX

PWR-950-AC

950 W AC power supply

12.2(14)SX

PWR-950-DC

950 W DC power supply

12.2(14)SX


All Other Power Supplies

Product ID
(append "=" for spares)
Product Description
Minimum Software Version
WS-CAC-6000W

6,000 W AC power supply

Note

Limited to 4,000 W in WS-C6509 and WS-C6506.

With releases earlier than Release 12.2(18)SXD, limited to 4,000 W in WS-C6506-E and WS-C6509-E.

12.2(18)SXD

PWR-4000-DC

4,000 W DC power supply

12.2(14)SX

WS-CAC-4000W

4,000 W AC power supply

12.2(14)SX

+WS-CAC-3000W

3,000 W AC power supply

Note

Required with Supervisor Engine 720 in WS-C6509-NEB or OSR7609.

Included in the WS-6509-NEB-UPGRD= upgrade kit.

12.2(17a)SX

WS-CAC-3000W

3,000 W AC power supply

12.2(14)SX

WS-CAC-2500W

2,500 W AC power supply

12.2(14)SX

WS-CDC-2500W

2,500 W DC power supply

12.2(14)SX


Chassis

13-Slot Chassis

9-Slot Chassis

6-Slot Chassis

4-Slot Chassis

3-Slot Chassis

13-Slot Chassis

Product ID
(append "=" for spare)
Product Description
Minimum Software Version
WS-C6513

Catalyst 6513 chassis:

13 slots

64 chassis MAC addresses

Use with Supervisor Engine 720 requires WS-C6K-13SLT-FAN2

Does not support WS-C6500-SFM

These modules are supported only in slots 9 through 13 and do not power up in other slots:

WS-X6708-10GE

WS-X6704-10GE

WS-X6748-SFP

WS-X6816-GBIC

WS-X6748-GE-TX

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

CISCO7613

Cisco 7613 chassis:

13 slots

64 chassis MAC addresses

Use with Supervisor Engine 720 requires WS-C6K-13SLT-FAN2

Does not support WS-C6500-SFM

These modules are supported only in slots 9 through 13 and do not power up in other slots:

WS-X6708-10GE

WS-X6704-10GE

WS-X6748-SFP

WS-X6816-GBIC

WS-X6748-GE-TX

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB


9-Slot Chassis

Product ID
(append "=" for spare)
Product Description
Minimum Software Version
WS-C6509-E

Catalyst 6509 chassis:

9 horizontal slots

1024 chassis MAC addresses

Requires WS-C6509-E-FAN

Requires 2,500 W or higher power supply

With releases earlier than Release 12.2(18)SXD, WS-CAC-6000W is limited to 4,000 W in WS-C6509-E

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-C6509

Catalyst 6509 chassis:

9 horizontal slots

1024 chassis MAC addresses

Use with Supervisor Engine 720 requires WS-C6K-9SLOT-FAN2

WS-CAC-6000W is limited to 4,000 W in WS-C6509

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-C6509-NEB-A

Catalyst 6509-NEB chassis

9 vertical slots

64 chassis MAC addresses

No fan tray upgrade required for use with Supervisor Engine 720

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-C6509-NEB

Catalyst 6509-NEB chassis:

9 vertical slots

1024 chassis MAC addresses

Use with Supervisor Engine 720 or Supervisor Engine 32 requires the WS-6509-NEB-UPGRD= upgrade kit—refer to this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_16162.htm

With Supervisor Engine 720

12.2(17a)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

CISCO7609

Cisco 7609 chassis

9 vertical slots

64 chassis MAC addresses

No fan tray upgrade required for use with Supervisor Engine 720

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

OSR-7609

Cisco 7609 chassis:

9 vertical slots

1024 chassis MAC addresses

Use with Supervisor Engine 720 requires the WS-6509-NEB-UPGRD= upgrade kit—refer to this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_16162.htm

With Supervisor Engine 720

12.2(17a)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB


6-Slot Chassis

Product ID
(append "=" for spare)
Product Description
Minimum Software Version
WS-C6506-E

Catalyst 6506 chassis:

6 slots

1024 chassis MAC addresses

Requires WS-C6506-E-FAN

Requires 2,500 W or higher power supply

With releases earlier than Release 12.2(18)SXD, WS-CAC-6000W is limited to 4,000 W in WS-C6506-E

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-C6506

Catalyst 6506 chassis:

6 slots

1024 chassis MAC addresses

Use with Supervisor Engine 720 requires WS-C6K-6SLOT-FAN2

WS-CAC-6000W limited to 4,000 W in WS-C6506

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

CISCO7606

Cisco 7606 chassis:

6 slots

64 chassis MAC addresses

Use with Supervisor Engine 720 requires FAN-MOD-6HS

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB


4-Slot Chassis

Product ID
(append "=" for spare)
Product Description
Minimum Software Version
WS-C6504-E

Catalyst 6504-E chassis:

4 slots

64 chassis MAC addresses

Does not support:

Supervisor Engine 2

WS-X6500-SFM2

WS-C6500-SFM

WS-F6K-DFC

With Supervisor Engine 720

12.2(18)SXE

With Supervisor Engine 32

12.2(18)SXF

CISCO7604

Cisco 7604 chassis:

4 slots

64 chassis MAC addresses

Does not support:

Supervisor Engine 2

WS-X6500-SFM2

WS-C6500-SFM

WS-F6K-DFC

With Supervisor Engine 720:

12.2(18)SXE

With Supervisor Engine 32

12.2(18)SXF


3-Slot Chassis

Product ID
(append "=" for spare)
Product Description
Minimum Software Version
WS-C6503-E

3 slots

64 chassis MAC addresses

Use with Supervisor Engine 720 requires WS-C6503-E-FAN

With Release 12.2(18)SXD and later releases, WS-C6503-E supports:

WS-X6704-10GE

WS-X6748-SFP

WS-X6724-SFP

WS-X6748-GE-TX

With releases earlier than Release 12.2(18)SXD, WS-C6503-E has the same support restrictions as WS-C6503.

WS-C6503-E does not support:

WS-X6500-SFM2

WS-C6500-SFM

WS-F6K-DFC

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

WS-C6503

Catalyst 6503 chassis:

3 slots

64 chassis MAC addresses

Use with Supervisor Engine 720 requires FAN-MOD-3HS

Does not support:

WS-X6708-10GE

WS-X6704-10GE

WS-X6748-SFP

WS-X6724-SFP

WS-X6748-GE-TX

WS-X6500-SFM2

WS-C6500-SFM

WS-F6K-DFC

With Supervisor Engine 720

12.2(14)SX

With Supervisor Engine 32

12.2(18)SXF

With Supervisor Engine 2

12.2(17d)SXB

CISCO7603

Cisco 7603 chassis:

3 slots

64 chassis MAC addresses

Use with Supervisor Engine 720 requires FAN-MOD-3HS

Does not support:

WS-X6708-10GE

WS-X6704-10GE

WS-X6748-SFP

WS-X6724-SFP

WS-X6748-GE-TX

WS-X6500-SFM2

WS-C6500-SFM

WS-F6K-DFC

With Supervisor Engine 720:

12.2(14)SX

With Supervisor Engine 2

12.2(17d)SXB

Note Supervisor Engine 32 does not support CISCO7603.


Unsupported Hardware

The following hardware is not supported:

See the "Supervisor Engine 32 (CAT6000-SUP32/MSFC2A, 7600-SUP32/MSFC2A)" section for information about hardware that is not supported with the Supervisor Engine 32.

With a Supervisor Engine 720, WS-X6516-GBIC hardware revisions 5.0 through 5.4 with a DFC3 installed.

Supervisor Engine 720 supports a DFC3 on these WS-X6516-GBIC hardware revisions:

Lower than 5.0

5.5 and higher

With a Supervisor Engine 720 and a DFC3 installed, WS-X6516-GBIC hardware revisions 5.0 through 5.3 do not power up. Without a DFC3, WS-X6516-GBIC hardware revisions 5.0 through 5.4 operate in bus mode.

See external field notice 24494 for more information:

http://www.cisco.com/warp/public/770/fn24494.shtml

These service modules:

WS-X6381-IDS Intrusion Detection System (IDS) Module

WS-X6380-NAM Network Analysis Module (NAM)

Supervisor Engine 1 (WS-X6K-S1A-MSFC2, WS-X6K-SUP1A-MSFC)

WS-X6624-FXS, WS-X6608-T1, and WS-X6608-E1 voice modules

WS-X6101-OC12-MMF and WS-X6101-OC12-SMF ATM LANE modules

WS-X6302-MSM Multilayer Switch Module

Catalyst 6000 series chassis

These power supplies cannot support high-capacity fan trays:

WS-CAC-1300W

WS-CDC-1300W

WS-CAC-1000W

Unsupported modules remain powered down if detected and do not affect system behavior.

FPD Image Packages


NoteField Programmable Device (FPD) image packages were first introduced on the Catalyst 6500 series switches and Cisco 7600 series routers in Release 12.2(18)SXE.

FPD image packages update FPD images. If a discrepancy exists between an FPD image and the Cisco IOS image, the module that has the FPD discrepancy is deactivated until the discrepancy is resolved.


These sections describe FPD packages:

FPD-Image Dependant Modules

FPD Image Package Contents

FPD Upgrades

FPD-Image Dependant Modules

In Release 12.2(18)SXE and later releases, these modules use FPD images:

Shared Port Adapter ( SPA) Interface Processors ( SIPs)

Shared Port Adapters

Enhanced FlexWAN Module ( WS-X6582-2PA)


Note With Release 12.2(18)SXE2 and later releases, you do not need to do a separate FPD image upgrade for the Enhanced FlexWAN module, because the Cisco IOS software images contain the FPD image for the Enhanced FlexWAN module. The FPD image package also includes the FPD image for the Enhanced FlexWAN module. (CSCin90971)


FPD Image Package Contents

These sections describe the FPD image package contents:

Release 12.2(18)SXF5 FPD Image Package Contents

Release 12.2(18)SXF4 FPD Image Package Contents

Release 12.2(18)SXF3 FPD Image Package Contents

Release 12.2(18)SXF2 FPD Image Package Contents

Release 12.2(18)SXF1 FPD Image Package Contents

Release 12.2(18)SXF FPD Image Package Contents

Release 12.2(18)SXE6 FPD Image Package Contents

Release 12.2(18)SXE5 FPD Image Package Contents

Release 12.2(18)SXE4 FPD Image Package Contents

Release 12.2(18)SXE3 FPD Image Package Contents

Release 12.2(18)SXE2 FPD Image Package Contents

Release 12.2(18)SXE1 FPD Image Package Contents

Release 12.2(18)SXF5 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXF5.pkg command:

Cisco Field Programmable Device Image Package for IOS
C7600 Family FPD Image Package (c7600-fpd-pkg.122-18.SXF5.pkg), Version 12.2(18)SXF5
Copyright (c) 2004-2006 by cisco Systems, Inc.
Built Sun 02-Jul-2006 20:09 by 

=============================== ==========================================================
                                            Bundled FPD Image Version Matrix
                                ==========================================================
                                                                                Min. Req.
Supported Card Types            ID  Image Name                       Version    H/W Ver.
=============================== == =============================== =========== ===========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON                     2.12        0.140  
                                 1 CTE1 SPA ROMMON NP                  2.12        0.0    
                                 2 CTE1 SPA I/O FPGA                   2.5         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    2.5         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  1.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    2.5         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  1.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
                                 1 1-Port POS/RPR SPA IOFPGA P2        1.2         2.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA                0.14        0.0    
                                 2 SNOOP BUS FPGA                      0.3         0.0    
------------------------------- -- ------------------------------- ----------- -----------
10-port GE SPA                   1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
5-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port 10GE SPA                  1 10GE SPA FPGA                       1.7         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port IPSec SPA                 1 PROM                                1.1         0.1    
                                 2 LODI                                1.21        0.1    
                                 3 Sequoia                             1.1         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-200                          1 SIP-200 I/O FPGA P1                 1.1         0.100  
                                 1 SIP-200 I/O FPGA P4                 1.1         0.400  
                                 1 SIP-200 I/O FPGA P6                 1.1         0.600  
                                 2 SIP-200 EOS FPGA P1                 0.27        0.100  
                                 2 SIP-200 EOS FPGA P450               1.211       0.450  
                                 2 SIP-200 EOS FPGA P5                 0.27        0.500  
                                 2 SIP-200 EOS FPGA P550               1.211       0.550  
                                 2 SIP-200 EOS FPGA P6                 1.218       0.600  
                                 3 SIP-200 PEG TX FPGA P1              1.129       0.100  
                                 3 SIP-200 PEG TX FPGA P6              1.131       0.600  
                                 4 SIP-200 PEG RX FPGA P1              1.3         0.100  
                                 4 SIP-200 PEG RX FPGA P4              1.3         0.400  
                                 4 SIP-200 PEG RX FPGA P6              1.3         0.600  
                                 5 SIP-200 ROMMON                      1.3         0.100  
------------------------------- -- ------------------------------- ----------- -----------
SIP-400                          1 SIP-400 ROMMON                      1.3         0.1    
                                 2 SIP-400 I/O FPGA                    0.82        0.1    
                                 3 SIP-400 SWITCH FPGA                 0.29        0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-600                          1 SIP-600 ROMMON                      1.3         0.1    
                                 2 SIP-600 I/O FPGA                    0.3         0.1    
                                 3 SIP-600 PKT ENG FPGA                0.5         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SSC-600                          1 SSC-600 I/O FPGA                    1.0         0.3    
                                 2 SSC-600 DP RX FPGA                  1.1         0.3    
                                 3 SSC-600 DP TX FPGA P3               0.12288     0.3    
                                 3 SSC-600 DP TX FPGA P4               0.16384     0.4    
                                 3 SSC-600 DP TX FPGA P5               1.3         0.5    
                                 4 SSC-600 ROMMON                      1.3         0.3    
------------------------------- -- ------------------------------- ----------- -----------
CWPA2                            1 CWPA2 I/O FPGA P1                   0.37        0.1    
                                 1 CWPA2 I/O FPGA P7                   0.39        2.0    
                                 2 CWPA2 EOS FPGA P1                   0.28        0.1    
                                 2 CWPA2 EOS FPGA P7                   0.48        2.0    
                                 3 CWPA2 CPU0 ROMMON                   1.3         0.1    
                                 4 CWPA2 CPU1 ROMMON                   1.3         0.1    
=============================== ==========================================================

Release 12.2(18)SXF4 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXF4.pkg command:

Cisco Field Programmable Device Image Package for IOS
C7600 Family FPD Image Package (c7600-fpd-pkg.122-18.SXF4.pkg), Version 12.2(18)SXF4
Copyright (c) 2004-2006 by cisco Systems, Inc.
Built Thu 23-Mar-2006 16:01 by 

=============================== ==========================================================
                                            Bundled FPD Image Version Matrix
                                ==========================================================
                                                                                Min. Req.
Supported Card Types            ID  Image Name                       Version    H/W Ver.
=============================== == =============================== =========== ===========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON                     2.12        0.140  
                                 1 CTE1 SPA ROMMON NP                  2.12        0.0    
                                 2 CTE1 SPA I/O FPGA                   2.1         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    2.1         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  1.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    2.1         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  1.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
                                 1 1-Port POS/RPR SPA IOFPGA P2        1.2         2.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA                0.14        0.0    
                                 2 SNOOP BUS FPGA                      0.3         0.0    
------------------------------- -- ------------------------------- ----------- -----------
10-port GE SPA                   1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
5-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port 10GE SPA                  1 10GE SPA FPGA                       1.7         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port IPSec SPA                 1 PROM                                1.1         0.1    
                                 2 LODI                                1.21        0.1    
                                 3 Sequoia                             1.1         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-200                          1 SIP-200 I/O FPGA P1                 1.1         0.100  
                                 1 SIP-200 I/O FPGA P4                 1.1         0.400  
                                 1 SIP-200 I/O FPGA P6                 1.1         0.600  
                                 2 SIP-200 EOS FPGA P1                 0.27        0.100  
                                 2 SIP-200 EOS FPGA P450               1.211       0.450  
                                 2 SIP-200 EOS FPGA P5                 0.27        0.500  
                                 2 SIP-200 EOS FPGA P550               1.211       0.550  
                                 2 SIP-200 EOS FPGA P6                 1.218       0.600  
                                 3 SIP-200 PEG TX FPGA P1              1.129       0.100  
                                 3 SIP-200 PEG TX FPGA P6              1.131       0.600  
                                 4 SIP-200 PEG RX FPGA P1              1.3         0.100  
                                 4 SIP-200 PEG RX FPGA P4              1.3         0.400  
                                 4 SIP-200 PEG RX FPGA P6              1.3         0.600  
                                 5 SIP-200 ROMMON                      1.3         0.100  
------------------------------- -- ------------------------------- ----------- -----------
SIP-400                          1 SIP-400 ROMMON                      1.3         0.1    
                                 2 SIP-400 I/O FPGA                    0.82        0.1    
                                 3 SIP-400 SWITCH FPGA                 0.29        0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-600                          1 SIP-600 ROMMON                      1.3         0.1    
                                 2 SIP-600 I/O FPGA                    0.3         0.1    
                                 3 SIP-600 PKT ENG FPGA                0.5         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SSC-600                          1 SSC-600 I/O FPGA                    1.0         0.3    
                                 2 SSC-600 DP RX FPGA                  1.1         0.3    
                                 3 SSC-600 DP TX FPGA P3               0.12288     0.3    
                                 3 SSC-600 DP TX FPGA P4               0.16384     0.4    
                                 3 SSC-600 DP TX FPGA P5               1.3         0.5    
                                 4 SSC-600 ROMMON                      1.3         0.3    
------------------------------- -- ------------------------------- ----------- -----------
CWPA2                            1 CWPA2 I/O FPGA P1                   0.37        0.1    
                                 1 CWPA2 I/O FPGA P7                   0.39        2.0    
                                 2 CWPA2 EOS FPGA P1                   0.28        0.1    
                                 2 CWPA2 EOS FPGA P7                   0.48        2.0    
                                 3 CWPA2 CPU0 ROMMON                   1.3         0.1    
                                 4 CWPA2 CPU1 ROMMON                   1.3         0.1    
=============================== ==========================================================

Release 12.2(18)SXF3 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXF3.pkg command:

Cisco Field Programmable Device Image Package for IOS
C7600 Family FPD Image Package (c7600-fpd-pkg.122-18.SXF3.pkg), Version 12.2(18)SXF3
Copyright (c) 2004-2006 by cisco Systems, Inc.
Built Tue 14-Feb-2006 14:02 by 

=============================== ================================================
                                        Bundled FPD Image Version Matrix
                                ================================================
                                                                       Min. Req.
Supported Card Types            ID  Image Name                Version  H/W Ver.
=============================== == ========================= ========= =========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON              2.12      0.140 
                                 1 CTE1 SPA ROMMON NP           2.12      0.0   
                                 2 CTE1 SPA I/O FPGA            2.1       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             2.1       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           0.15      0.200 
------------------------------- -- ------------------------- --------- ---------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             2.1       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           0.15      0.200 
------------------------------- -- ------------------------- --------- ---------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
                                 1 1-Port POS/RPR SPA IOFPGA    1.2       2.0   
------------------------------- -- ------------------------- --------- ---------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA         0.14      0.0   
                                 2 SNOOP BUS FPGA               0.3       0.0   
------------------------------- -- ------------------------- --------- ---------
10-port GE SPA                   1 GE SPA FPGA                  1.8       0.0   
------------------------------- -- ------------------------- --------- ---------
5-port GE SPA                    1 GE SPA FPGA                  1.8       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port GE SPA                    1 GE SPA FPGA                  1.8       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port 10GE SPA                  1 10GE SPA FPGA                1.7       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port IPSec SPA                 1 PROM                         1.1       0.1   
                                 2 LODI                         1.21      0.1   
                                 3 Sequoia                      1.1       0.1   
------------------------------- -- ------------------------- --------- ---------
SIP-200                          1 SIP-200 I/O FPGA P1          1.1       0.100 
                                 1 SIP-200 I/O FPGA P4          1.1       0.400 
                                 1 SIP-200 I/O FPGA P6          1.1       0.600 
                                 2 SIP-200 EOS FPGA P1          0.27      0.100 
                                 2 SIP-200 EOS FPGA P450        1.211     0.450 
                                 2 SIP-200 EOS FPGA P5          0.27      0.500 
                                 2 SIP-200 EOS FPGA P550        1.211     0.550 
                                 2 SIP-200 EOS FPGA P6          1.218     0.600 
                                 3 SIP-200 PEG TX FPGA P1       1.129     0.100 
                                 3 SIP-200 PEG TX FPGA P6       1.131     0.600 
                                 4 SIP-200 PEG RX FPGA P1       1.3       0.100 
                                 4 SIP-200 PEG RX FPGA P4       1.3       0.400 
                                 4 SIP-200 PEG RX FPGA P6       1.3       0.600 
                                 5 SIP-200 ROMMON               1.3       0.100 
------------------------------- -- ------------------------- --------- ---------
SIP-400                          1 SIP-400 ROMMON               1.3       0.1   
                                 2 SIP-400 I/O FPGA             0.82      0.1   
                                 3 SIP-400 SWITCH FPGA          0.29      0.1   
------------------------------- -- ------------------------- --------- ---------
SIP-600                          1 SIP-600 ROMMON               1.3       0.1   
                                 2 SIP-600 I/O FPGA             0.3       0.1   
                                 3 SIP-600 PKT ENG FPGA         0.5       0.1   
------------------------------- -- ------------------------- --------- ---------
SSC-600                          1 SSC-600 I/O FPGA             1.0       0.3   
                                 2 SSC-600 DP RX FPGA           1.1       0.3   
                                 3 SSC-600 DP TX FPGA P3        0.12288    0.3  
 
                                 3 SSC-600 DP TX FPGA P4        0.16384    0.4  
 
                                 3 SSC-600 DP TX FPGA P5        1.3       0.5   
                                 4 SSC-600 ROMMON               1.3       0.3   
------------------------------- -- ------------------------- --------- ---------
CWPA2                            1 CWPA2 I/O FPGA P1            0.37      0.1   
                                 1 CWPA2 I/O FPGA P7            0.39      2.0   
                                 2 CWPA2 EOS FPGA P1            0.28      0.1   
                                 2 CWPA2 EOS FPGA P7            0.48      2.0   
                                 3 CWPA2 CPU0 ROMMON            1.3       0.1   
                                 4 CWPA2 CPU1 ROMMON            1.3       0.1   
=============================== ================================================

Release 12.2(18)SXF2 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXF2.pkg command:

Cisco Field Programmable Device Image Package for IOS
C7600 Family FPD Image Package (c7600-fpd-pkg.122-18.SXF2.pkg), Version 12.2(18)SXF2
Copyright (c) 2004-2006 by cisco Systems, Inc.
Built Thu 19-Jan-2006 01:08 by 


=============================== ==========================================================
                                            Bundled FPD Image Version Matrix
                                ==========================================================
                                                                                Min. Req.
Supported Card Types            ID  Image Name                       Version    H/W Ver.
=============================== == =============================== =========== ===========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON                     2.12        0.140  
                                 1 CTE1 SPA ROMMON NP                  2.12        0.0    
                                 2 CTE1 SPA I/O FPGA                   2.1         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    2.1         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  0.15        0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    2.1         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  0.15        0.200  
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
                                 1 1-Port POS/RPR SPA IOFPGA P2        1.2         2.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA                0.14        0.0    
                                 2 SNOOP BUS FPGA                      0.3         0.0    
------------------------------- -- ------------------------------- ----------- -----------
10-port GE SPA                   1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
5-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port 10GE SPA                  1 10GE SPA FPGA                       1.7         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port IPsec SPA                 1 PROM                                1.1         0.1    
                                 2 LODI                                1.21        0.1    
                                 3 Sequoia                             1.1         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-200                          1 SIP-200 I/O FPGA P1                 1.1         0.100  
                                 1 SIP-200 I/O FPGA P4                 1.1         0.400  
                                 1 SIP-200 I/O FPGA P6                 1.1         0.600  
                                 2 SIP-200 EOS FPGA P1                 0.27        0.100  
                                 2 SIP-200 EOS FPGA P450               1.211       0.450  
                                 2 SIP-200 EOS FPGA P5                 0.27        0.500  
                                 2 SIP-200 EOS FPGA P550               1.211       0.550  
                                 2 SIP-200 EOS FPGA P6                 1.218       0.600  
                                 3 SIP-200 PEG TX FPGA P1              1.129       0.100  
                                 3 SIP-200 PEG TX FPGA P6              1.131       0.600  
                                 4 SIP-200 PEG RX FPGA P1              1.3         0.100  
                                 4 SIP-200 PEG RX FPGA P4              1.3         0.400  
                                 4 SIP-200 PEG RX FPGA P6              1.3         0.600  
                                 5 SIP-200 ROMMON                      1.3         0.100  
------------------------------- -- ------------------------------- ----------- -----------
SIP-400                          1 SIP-400 ROMMON                      1.3         0.1    
                                 2 SIP-400 I/O FPGA                    0.82        0.1    
                                 3 SIP-400 SWITCH FPGA                 0.25        0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-600                          1 SIP-600 ROMMON                      1.3         0.1    
                                 2 SIP-600 I/O FPGA                    0.3         0.1    
                                 3 SIP-600 PKT ENG FPGA                0.5         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SSC-600                          1 SSC-600 I/O FPGA                    1.0         0.3    
                                 2 SSC-600 DP RX FPGA                  1.1         0.3    
                                 3 SSC-600 DP TX FPGA P3               0.12288     0.3    
                                 3 SSC-600 DP TX FPGA P4               0.16384     0.4    
                                 3 SSC-600 DP TX FPGA P5               1.3         0.5    
                                 4 SSC-600 ROMMON                      1.3         0.3    
------------------------------- -- ------------------------------- ----------- -----------
CWPA2                            1 CWPA2 I/O FPGA P1                   0.37        0.1    
                                 1 CWPA2 I/O FPGA P7                   0.39        2.0    
                                 2 CWPA2 EOS FPGA P1                   0.28        0.1    
                                 2 CWPA2 EOS FPGA P7                   0.48        2.0    
                                 3 CWPA2 CPU0 ROMMON                   1.3         0.1    
                                 4 CWPA2 CPU1 ROMMON                   1.3         0.1    
=============================== ==========================================================

Release 12.2(18)SXF1 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXF1.pkg command:

Cisco Field Programmable Device Image Package for IOS
C7600 Family FPD Image Package (c7600-fpd-pkg.122-18.SXF1.pkg), Version 12.2(18)SXF1
Copyright (c) 2004-2005 by cisco Systems, Inc.
Built Wed 21-Dec-2005 09:14 by kellmill

=============================== ==========================================================
                                            Bundled FPD Image Version Matrix
                                ==========================================================
                                                                                Min. Req.
Supported Card Types            ID  Image Name                       Version    H/W Ver.
=============================== == =============================== =========== ===========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON                     2.12        0.140  
                                 1 CTE1 SPA ROMMON NP                  2.12        0.0    
                                 2 CTE1 SPA I/O FPGA                   1.6         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    1.4         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  0.15        0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    1.4         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  0.15        0.200  
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
                                 1 1-Port POS/RPR SPA IOFPGA P2        1.2         2.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA                0.14        0.0    
                                 2 SNOOP BUS FPGA                      0.3         0.0    
------------------------------- -- ------------------------------- ----------- -----------
10-port GE SPA                   1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
5-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port 10GE SPA                  1 10GE SPA FPGA                       1.7         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port IPsec SPA                 1 PROM                                1.1         0.1    
                                 2 LODI                                1.21        0.1    
                                 3 Sequoia                             1.1         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-200                          1 SIP-200 I/O FPGA P1                 1.1         0.100  
                                 1 SIP-200 I/O FPGA P4                 1.1         0.400  
                                 1 SIP-200 I/O FPGA P6                 1.1         0.600  
                                 2 SIP-200 EOS FPGA P1                 0.27        0.100  
                                 2 SIP-200 EOS FPGA P450               1.211       0.450  
                                 2 SIP-200 EOS FPGA P5                 0.27        0.500  
                                 2 SIP-200 EOS FPGA P550               1.211       0.550  
                                 2 SIP-200 EOS FPGA P6                 1.218       0.600  
                                 3 SIP-200 PEG TX FPGA P1              1.129       0.100  
                                 3 SIP-200 PEG TX FPGA P6              1.131       0.600  
                                 4 SIP-200 PEG RX FPGA P1              1.3         0.100  
                                 4 SIP-200 PEG RX FPGA P4              1.3         0.400  
                                 4 SIP-200 PEG RX FPGA P6              1.3         0.600  
                                 5 SIP-200 ROMMON                      1.3         0.100  
------------------------------- -- ------------------------------- ----------- -----------
SIP-400                          1 SIP-400 ROMMON                      1.3         0.1    
                                 2 SIP-400 I/O FPGA                    0.82        0.1    
                                 3 SIP-400 SWITCH FPGA                 0.25        0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-600                          1 SIP-600 ROMMON                      1.3         0.1    
                                 2 SIP-600 I/O FPGA                    0.2         0.1    
                                 3 SIP-600 PKT ENG FPGA                0.5         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SSC-600                          1 SSC-600 I/O FPGA                    1.0         0.3    
                                 2 SSC-600 DP RX FPGA                  1.0         0.3    
                                 3 SSC-600 DP TX FPGA P3               0.12288     0.3    
                                 3 SSC-600 DP TX FPGA P4               0.16384     0.4    
                                 3 SSC-600 DP TX FPGA P5               1.3         0.5    
                                 4 SSC-600 ROMMON                      1.2         0.3    
------------------------------- -- ------------------------------- ----------- -----------
CWPA2                            1 CWPA2 I/O FPGA P1                   0.37        0.1    
                                 1 CWPA2 I/O FPGA P7                   0.39        2.0    
                                 2 CWPA2 EOS FPGA P1                   0.28        0.1    
                                 2 CWPA2 EOS FPGA P7                   0.48        2.0    
                                 3 CWPA2 CPU0 ROMMON                   1.3         0.1    
                                 4 CWPA2 CPU1 ROMMON                   1.3         0.1    
=============================== ==========================================================

Release 12.2(18)SXF FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXF.pkg command:

=============================== ==========================================================
                                            Bundled FPD Image Version Matrix
                                ==========================================================
                                                                                Min. Req.
Supported Card Types            ID  Image Name                       Version    H/W Ver.
=============================== == =============================== =========== ===========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON                     2.12        0.0    
                                 2 T3E3 SPA I/O FPGA                   0.24        0.0    
                                 3 T3E3 SPA E3 FPGA                    0.6         0.0    
                                 4 T3E3 SPA T3 FPGA                    0.14        0.0    
------------------------------- -- ------------------------------- ----------- -----------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON                     2.12        0.140  
                                 1 CTE1 SPA ROMMON NP                  2.12        0.0    
                                 2 CTE1 SPA I/O FPGA                   1.6         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    1.4         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  0.15        0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON                      2.12        0.100  
                                 2 CT3 SPA I/O FPGA                    1.4         0.100  
                                 3 CT3 SPA T3 FPGA R1                  0.11        0.100  
                                 3 CT3 SPA T3 FPGA R2                  0.15        0.200  
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1                   3.4         0.0    
                                 1 POS SPA IOFPGA P2                   3.4         0.200  
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA P1        1.2         0.0    
                                 1 1-Port POS/RPR SPA IOFPGA P2        1.2         2.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA                     1.24        0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA                0.14        0.0    
                                 2 SNOOP BUS FPGA                      0.3         0.0    
------------------------------- -- ------------------------------- ----------- -----------
10-port GE SPA                   1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
5-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port GE SPA                    1 GE SPA FPGA                         1.8         0.0    
------------------------------- -- ------------------------------- ----------- -----------
1-port 10GE SPA                  1 10GE SPA FPGA                       1.7         0.0    
------------------------------- -- ------------------------------- ----------- -----------
2-port IPsec SPA                 1 PROM                                1.1         0.1    
                                 2 LODI                                1.21        0.1    
                                 3 Sequoia                             1.1         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-200                          1 SIP-200 I/O FPGA P1                 1.1         0.100  
                                 1 SIP-200 I/O FPGA P4                 1.1         0.400  
                                 1 SIP-200 I/O FPGA P6                 1.1         0.600  
                                 2 SIP-200 EOS FPGA P1                 0.27        0.100  
                                 2 SIP-200 EOS FPGA P450               1.211       0.450  
                                 2 SIP-200 EOS FPGA P5                 0.27        0.500  
                                 2 SIP-200 EOS FPGA P550               1.211       0.550  
                                 2 SIP-200 EOS FPGA P6                 1.218       0.600  
                                 3 SIP-200 PEG TX FPGA P1              1.129       0.100  
                                 3 SIP-200 PEG TX FPGA P6              1.131       0.600  
                                 4 SIP-200 PEG RX FPGA P1              1.3         0.100  
                                 4 SIP-200 PEG RX FPGA P4              1.3         0.400  
                                 4 SIP-200 PEG RX FPGA P6              1.3         0.600  
                                 5 SIP-200 ROMMON                      1.3         0.100  
------------------------------- -- ------------------------------- ----------- -----------
SIP-400                          1 SIP-400 ROMMON                      1.3         0.1    
                                 2 SIP-400 I/O FPGA                    0.82        0.1    
                                 3 SIP-400 SWITCH FPGA                 0.25        0.1    
------------------------------- -- ------------------------------- ----------- -----------
SIP-600                          1 SIP-600 ROMMON                      1.3         0.1    
                                 2 SIP-600 I/O FPGA                    0.2         0.1    
                                 3 SIP-600 PKT ENG FPGA                0.5         0.1    
------------------------------- -- ------------------------------- ----------- -----------
SSC-600                          1 SSC-600 I/O FPGA                    1.0         0.3    
                                 2 SSC-600 DP RX FPGA                  1.0         0.3    
                                 3 SSC-600 DP TX FPGA P3               0.12288     0.3    
                                 3 SSC-600 DP TX FPGA P4               0.16384     0.4    
                                 3 SSC-600 DP TX FPGA P5               1.3         0.5    
                                 4 SSC-600 ROMMON                      1.2         0.3    
------------------------------- -- ------------------------------- ----------- -----------
CWPA2                            1 CWPA2 I/O FPGA P1                   0.37        0.1    
                                 1 CWPA2 I/O FPGA P7                   0.39        2.0    
                                 2 CWPA2 EOS FPGA P1                   0.28        0.1    
                                 2 CWPA2 EOS FPGA P7                   0.48        2.0    
                                 3 CWPA2 CPU0 ROMMON                   1.3         0.1    
                                 4 CWPA2 CPU1 ROMMON                   1.3         0.1    
=============================== ==========================================================

Release 12.2(18)SXE6 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXE6.pkg command:

Cisco Field Programmable Device Image Package for IOS
C7600 Family FPD Image Package (c7600-fpd-pkg.122-18.SXE6.pkg), Version 12.2(18)SXE6
Copyright (c) 2004-2006 by cisco Systems, Inc.
Built Mon 05-Jun-2006 15:22 by 

=============================== ================================================
                                        Bundled FPD Image Version Matrix
                                ================================================
                                                                       Min. Req.
Supported Card Types            ID  Image Name                Version  H/W Ver.
=============================== == ========================= ========= =========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON              2.12      0.140 
                                 1 CTE1 SPA ROMMON NP           2.12      0.0   
                                 2 CTE1 SPA I/O FPGA            1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             2.4       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           1.4       0.200 
------------------------------- -- ------------------------- --------- ---------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             2.4       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           1.4       0.200 
------------------------------- -- ------------------------- --------- ---------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
2-port OC12 POS SPA              1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
                                 1 1-Port POS/RPR SPA IOFPGA    1.2       2.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC-48 POS/SRP HH SPA      1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
2-port DS3E3 ATM SPA             1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port DS3E3 ATM SPA             1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
2-port OC12 ATM SPA              1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA         0.10      0.0   
------------------------------- -- ------------------------- --------- ---------
10-port GE SPA                   1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
5-port GE SPA                    1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port GE SPA                    1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port 10GE SPA                  1 10GE SPA FPGA                1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port 10GE FH SPA               1 10GE SPA FPGA                1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port IPSec SPA                 1 PROM                         1.1       0.1   
                                 2 LODI                         1.21      0.1   
                                 3 Sequoia                      1.1       0.1   
------------------------------- -- ------------------------- --------- ---------
SIP-200                          1 SIP-200 I/O FPGA P1          1.1       0.100 
                                 1 SIP-200 I/O FPGA P4          1.1       0.400 
                                 1 SIP-200 I/O FPGA P6          1.1       0.600 
                                 2 SIP-200 EOS FPGA P1          0.27      0.100 
                                 2 SIP-200 EOS FPGA P450        1.211     0.450 
                                 2 SIP-200 EOS FPGA P5          0.27      0.500 
                                 2 SIP-200 EOS FPGA P550        1.211     0.550 
                                 2 SIP-200 EOS FPGA P6          1.211     0.600 
                                 3 SIP-200 PEG TX FPGA P1       1.129     0.100 
                                 3 SIP-200 PEG TX FPGA P6       1.129     0.600 
                                 4 SIP-200 PEG RX FPGA P1       1.3       0.100 
                                 4 SIP-200 PEG RX FPGA P4       1.3       0.400 
                                 4 SIP-200 PEG RX FPGA P6       1.3       0.600 
                                 5 SIP-200 ROMMON               1.2       0.100 
------------------------------- -- ------------------------- --------- ---------
SIP-400                          1 SIP-400 ROMMON               1.2       0.1   
                                 2 SIP-400 I/O FPGA             0.82      0.1   
                                 3 SIP-400 SWITCH FPGA          0.29      0.1   
------------------------------- -- ------------------------- --------- ---------
SSC-600                          1 SSC-600 I/O FPGA             1.0       0.3   
                                 2 SSC-600 DP RX FPGA           1.0       0.3   
                                 3 SSC-600 DP TX FPGA P3        0.12288    0.3  
 
                                 3 SSC-600 DP TX FPGA P4        0.16384    0.4  
 
                                 3 SSC-600 DP TX FPGA P5        1.3       0.5   
                                 4 SSC-600 ROMMON               1.2       0.3   
------------------------------- -- ------------------------- --------- ---------
CWPA2                            1 CWPA2 I/O FPGA P1            0.37      0.1   
                                 1 CWPA2 I/O FPGA P7            0.39      2.0   
                                 2 CWPA2 EOS FPGA P1            0.28      0.1   
                                 2 CWPA2 EOS FPGA P7            0.47      2.0   
                                 3 CWPA2 CPU0 ROMMON            1.2       0.1   
                                 4 CWPA2 CPU1 ROMMON            1.2       0.1   
=============================== ================================================

Release 12.2(18)SXE5 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXE5.pkg command:

Cisco Field Programmable Device Image Package for IOS
C7600 Family FPD Image Package (c7600-fpd-pkg.122-18.SXE5.pkg), Version 12.2(18)SXE5
Copyright (c) 2004-2006 by cisco Systems, Inc.
Built Wed 08-Feb-2006 13:30 by 


=============================== ================================================
                                        Bundled FPD Image Version Matrix
                                ================================================
                                                                       Min. Req.
Supported Card Types            ID  Image Name                Version  H/W Ver.
=============================== == ========================= ========= =========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON              2.12      0.140 
                                 1 CTE1 SPA ROMMON NP           2.12      0.0   
                                 2 CTE1 SPA I/O FPGA            1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             1.1       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           0.15      0.200 
------------------------------- -- ------------------------- --------- ---------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             1.1       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           0.15      0.200 
------------------------------- -- ------------------------- --------- ---------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
2-port OC12 POS SPA              1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
                                 1 1-Port POS/RPR SPA IOFPGA    1.2       2.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC-48 POS/SRP HH SPA      1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
2-port DS3E3 ATM SPA             1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port DS3E3 ATM SPA             1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
2-port OC12 ATM SPA              1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA         0.10      0.0   
------------------------------- -- ------------------------- --------- ---------
10-port GE SPA                   1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
5-port GE SPA                    1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port GE SPA                    1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port 10GE SPA                  1 10GE SPA FPGA                1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port 10GE FH SPA               1 10GE SPA FPGA                1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port IPSec SPA                 1 PROM                         1.1       0.1   
                                 2 LODI                         1.21      0.1   
                                 3 Sequoia                      1.1       0.1   
------------------------------- -- ------------------------- --------- ---------
SIP-200                          1 SIP-200 I/O FPGA P1          1.1       0.100 
                                 1 SIP-200 I/O FPGA P4          1.1       0.400 
                                 1 SIP-200 I/O FPGA P6          1.1       0.600 
                                 2 SIP-200 EOS FPGA P1          0.27      0.100 
                                 2 SIP-200 EOS FPGA P450        1.211     0.450 
                                 2 SIP-200 EOS FPGA P5          0.27      0.500 
                                 2 SIP-200 EOS FPGA P550        1.211     0.550 
                                 2 SIP-200 EOS FPGA P6          1.211     0.600 
                                 3 SIP-200 PEG TX FPGA P1       1.129     0.100 
                                 3 SIP-200 PEG TX FPGA P6       1.129     0.600 
                                 4 SIP-200 PEG RX FPGA P1       1.3       0.100 
                                 4 SIP-200 PEG RX FPGA P4       1.3       0.400 
                                 4 SIP-200 PEG RX FPGA P6       1.3       0.600 
                                 5 SIP-200 ROMMON               1.2       0.100 
------------------------------- -- ------------------------- --------- ---------
SIP-400                          1 SIP-400 ROMMON               1.2       0.1   
                                 2 SIP-400 I/O FPGA             0.82      0.1   
                                 3 SIP-400 SWITCH FPGA          0.29      0.1   
------------------------------- -- ------------------------- --------- ---------
SSC-600                          1 SSC-600 I/O FPGA             1.0       0.3   
                                 2 SSC-600 DP RX FPGA           1.0       0.3   
                                 3 SSC-600 DP TX FPGA P3        0.12288    0.3  
 
                                 3 SSC-600 DP TX FPGA P4        0.16384    0.4  
 
                                 3 SSC-600 DP TX FPGA P5        1.3       0.5   
                                 4 SSC-600 ROMMON               1.2       0.3   
------------------------------- -- ------------------------- --------- ---------
CWPA2                            1 CWPA2 I/O FPGA P1            0.37      0.1   
                                 1 CWPA2 I/O FPGA P7            0.39      2.0   
                                 2 CWPA2 EOS FPGA P1            0.28      0.1   
                                 2 CWPA2 EOS FPGA P7            0.47      2.0   
                                 3 CWPA2 CPU0 ROMMON            1.2       0.1   
                                 4 CWPA2 CPU1 ROMMON            1.2       0.1   
=============================== ================================================

Release 12.2(18)SXE4 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXE4.pkg command:

=============================== ================================================
                                        Bundled FPD Image Version Matrix
                                ================================================
                                                                       Min. Req.
Supported Card Types            ID  Image Name                Version  H/W Ver.
=============================== == ========================= ========= =========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON              2.12      0.140 
                                 1 CTE1 SPA ROMMON NP           2.12      0.0   
                                 2 CTE1 SPA I/O FPGA            1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             1.1       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           0.15      0.200 
------------------------------- -- ------------------------- --------- ---------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             1.1       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           0.15      0.200 
------------------------------- -- ------------------------- --------- ---------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
2-port OC12 POS SPA              1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
                                 1 1-Port POS/RPR SPA IOFPGA    1.2       2.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC-48 POS/SRP HH SPA      1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
2-port DS3E3 ATM SPA             1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port DS3E3 ATM SPA             1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
2-port OC12 ATM SPA              1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA         0.10      0.0   
------------------------------- -- ------------------------- --------- ---------
10-port GE SPA                   1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
5-port GE SPA                    1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port GE SPA                    1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port 10GE SPA                  1 10GE SPA FPGA                1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port 10GE FH SPA               1 10GE SPA FPGA                1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port IPsec SPA                 1 PROM                         1.1       0.1   
                                 2 LODI                         1.21      0.1   
                                 3 Sequoia                      1.1       0.1   
------------------------------- -- ------------------------- --------- ---------
SIP-200                          1 SIP-200 I/O FPGA P1          1.1       0.100 
                                 1 SIP-200 I/O FPGA P4          1.1       0.400 
                                 1 SIP-200 I/O FPGA P6          1.1       0.600 
                                 2 SIP-200 EOS FPGA P1          0.27      0.100 
                                 2 SIP-200 EOS FPGA P450        1.211     0.450 
                                 2 SIP-200 EOS FPGA P5          0.27      0.500 
                                 2 SIP-200 EOS FPGA P550        1.211     0.550 
                                 2 SIP-200 EOS FPGA P6          1.211     0.600 
                                 3 SIP-200 PEG TX FPGA P1       1.129     0.100 
                                 3 SIP-200 PEG TX FPGA P6       1.129     0.600 
                                 4 SIP-200 PEG RX FPGA P1       1.3       0.100 
                                 4 SIP-200 PEG RX FPGA P4       1.3       0.400 
                                 4 SIP-200 PEG RX FPGA P6       1.3       0.600 
                                 5 SIP-200 ROMMON               1.2       0.100 
------------------------------- -- ------------------------- --------- ---------
SIP-400                          1 SIP-400 ROMMON               1.2       0.1   
                                 2 SIP-400 I/O FPGA             0.82      0.1   
                                 3 SIP-400 SWITCH FPGA          0.25      0.1   
------------------------------- -- ------------------------- --------- ---------
SSC-600                          1 SSC-600 I/O FPGA             1.0       0.3   
                                 2 SSC-600 DP RX FPGA           1.0       0.3   
                                 3 SSC-600 DP TX FPGA P3        0.12288    0.3  
                                 3 SSC-600 DP TX FPGA P4        0.16384    0.4  
                                 3 SSC-600 DP TX FPGA P5        1.3       0.5   
                                 4 SSC-600 ROMMON               1.2       0.3   
------------------------------- -- ------------------------- --------- ---------
CWPA2                            1 CWPA2 I/O FPGA P1            0.37      0.1   
                                 1 CWPA2 I/O FPGA P7            0.39      2.0   
                                 2 CWPA2 EOS FPGA P1            0.28      0.1   
                                 2 CWPA2 EOS FPGA P7            0.47      2.0   
                                 3 CWPA2 CPU0 ROMMON            1.2       0.1   
                                 4 CWPA2 CPU1 ROMMON            1.2       0.1   
=============================== ================================================

Release 12.2(18)SXE3 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXE3.pkg command:

Cisco Field Programmable Device Image Package for IOS
C7600 Family FPD Image Package (c7600-fpd-pkg.122-18.SXE3.pkg), Version 12.2(18)
SXE3
Copyright (c) 2004-2005 by cisco Systems, Inc.
Built Wed 17-Aug-2005 01:27 by 


=============================== ================================================
                                        Bundled FPD Image Version Matrix
                                ================================================
                                                                       Min. Req.
Supported Card Types            ID  Image Name                Version  H/W Ver.
=============================== == ========================= ========= =========
2-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port T3/E3 Serial SPA          1 T3E3 SPA ROMMON              2.12      0.0   
                                 2 T3E3 SPA I/O FPGA            0.24      0.0   
                                 3 T3E3 SPA E3 FPGA             0.6       0.0   
                                 4 T3E3 SPA T3 FPGA             0.14      0.0   
------------------------------- -- ------------------------- --------- ---------
8-port Channelized T1/E1 SPA     1 CTE1 SPA ROMMON              2.12      0.140 
                                 1 CTE1 SPA ROMMON NP           2.12      0.0   
                                 2 CTE1 SPA I/O FPGA            1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             1.1       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           0.15      0.200 
------------------------------- -- ------------------------- --------- ---------
4-port Channelized T3 SPA        1 CT3 SPA ROMMON               2.12      0.100 
                                 2 CT3 SPA I/O FPGA             1.1       0.100 
                                 3 CT3 SPA T3 FPGA R1           0.11      0.100 
                                 3 CT3 SPA T3 FPGA R2           0.15      0.200 
------------------------------- -- ------------------------- --------- ---------
2-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
4-port OC3 POS SPA               1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC12 POS SPA              1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
2-port OC12 POS SPA              1 POS SPA IOFPGA P1            3.4       0.0   
                                 1 POS SPA IOFPGA P2            3.4       0.200 
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP FH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC-192 POS/SRP HH SPA     1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
                                 1 1-Port POS/RPR SPA IOFPGA    1.2       2.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC-48 POS/SRP HH SPA      1 1-Port POS/RPR SPA IOFPGA    1.2       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port OC3 ATM SPA               1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
2-port DS3E3 ATM SPA             1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
4-port DS3E3 ATM SPA             1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC12 ATM SPA              1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
2-port OC12 ATM SPA              1 KATM SPA IOFPGA              1.24      0.0   
------------------------------- -- ------------------------- --------- ---------
1-port OC48 ATM SPA              1 KATM OC48 SPA IOFPGA         0.10      0.0   
------------------------------- -- ------------------------- --------- ---------
10-port GE SPA                   1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
5-port GE SPA                    1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port GE SPA                    1 GE SPA FPGA                  1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port 10GE SPA                  1 10GE SPA FPGA                1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
1-port 10GE FH SPA               1 10GE SPA FPGA                1.6       0.0   
------------------------------- -- ------------------------- --------- ---------
2-port IPSec SPA                 1 PROM                         1.1       0.1   
                                 2 LODI                         1.21      0.1   
                                 3 Sequoia                      1.1       0.1   
------------------------------- -- ------------------------- --------- ---------
SIP-200                          1 SIP-200 I/O FPGA P1          1.1       0.100 
                                 1 SIP-200 I/O FPGA P4          1.1       0.400 
                                 1 SIP-200 I/O FPGA P6          1.1       0.600 
                                 2 SIP-200 EOS FPGA P1          0.27      0.100 
                                 2 SIP-200 EOS FPGA P450        1.211     0.450 
                                 2 SIP-200 EOS FPGA P5          0.27      0.500 
                                 2 SIP-200 EOS FPGA P550        1.211     0.550 
                                 2 SIP-200 EOS FPGA P6          1.211     0.600 
                                 3 SIP-200 PEG TX FPGA P1       1.129     0.100 
                                 3 SIP-200 PEG TX FPGA P6       1.129     0.600 
                                 4 SIP-200 PEG RX FPGA P1       1.3       0.100 
                                 4 SIP-200 PEG RX FPGA P4       1.3       0.400 
                                 4 SIP-200 PEG RX FPGA P6       1.3       0.600 
                                 5 SIP-200 ROMMON               1.2       0.100 
------------------------------- -- ------------------------- --------- ---------
SIP-400                          1 SIP-400 ROMMON               1.2       0.1   
                                 2 SIP-400 I/O FPGA             0.82      0.1   
                                 3 SIP-400 SWITCH FPGA          0.25      0.1   
------------------------------- -- ------------------------- --------- ---------
SSC-600                          1 SSC-600 I/O FPGA             1.0       0.3   
                                 2 SSC-600 DP RX FPGA           1.0       0.3   
                                 3 SSC-600 DP TX FPGA P3        0.12288    0.3  
 
                                 3 SSC-600 DP TX FPGA P4        0.16384    0.4  
 
                                 3 SSC-600 DP TX FPGA P5        1.3       0.5   
                                 4 SSC-600 ROMMON               1.2       0.3   
------------------------------- -- ------------------------- --------- ---------
CWPA2                            1 CWPA2 I/O FPGA P1            0.37      0.1   
                                 1 CWPA2 I/O FPGA P7            0.39      2.0   
                                 2 CWPA2 EOS FPGA P1            0.28      0.1   
                                 2 CWPA2 EOS FPGA P7            0.47      2.0   
                                 3 CWPA2 CPU0 ROMMON            1.2       0.1   
                                 4 CWPA2 CPU1 ROMMON            1.2       0.1   
=============================== ================================================

Release 12.2(18)SXE2 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXE2.pkg command:

============================ =============================================
                                 Bundled FPD Image Version Matrix
                             =============================================
                                                               Min. Req.
Supported Card Types         ID  Image Name             Version  H/W Ver.
============================ == ====================== ========= =========
2-port T3/E3 Serial SPA       1 T3E3 SPA ROMMON           2.12      0.0   
                              2 T3E3 SPA I/O FPGA         0.24      0.0   
                              3 T3E3 SPA E3 FPGA          0.6       0.0   
                              4 T3E3 SPA T3 FPGA          0.14      0.0   
---------------------------- -- ---------------------- --------- ---------
4-port T3/E3 Serial SPA       1 T3E3 SPA ROMMON           2.12      0.0   
                              2 T3E3 SPA I/O FPGA         0.24      0.0   
                              3 T3E3 SPA E3 FPGA          0.6       0.0   
                              4 T3E3 SPA T3 FPGA          0.14      0.0   
---------------------------- -- ---------------------- --------- ---------
8-port Channelized T1/E1 SPA  1 CTE1 SPA ROMMON           2.12      0.140
                              1 CTE1 SPA ROMMON NP        2.12      0.0   
                              2 CTE1 SPA I/O FPGA         1.2       0.0   
---------------------------- -- ---------------------- --------- ---------
2-port Channelized T3 SPA     1 CT3 SPA ROMMON            2.12      0.100
                              2 CT3 SPA I/O FPGA          1.1       0.100
                              3 CT3 SPA T3 FPGA R1        0.11      0.100
                              3 CT3 SPA T3 FPGA R2        0.15      0.200
---------------------------- -- ---------------------- --------- ---------
4-port Channelized T3 SPA     1 CT3 SPA ROMMON            2.12      0.100
                              2 CT3 SPA I/O FPGA          1.1       0.100
                              3 CT3 SPA T3 FPGA R1        0.11      0.100
                              3 CT3 SPA T3 FPGA R2        0.15      0.200
---------------------------- -- ---------------------- --------- ---------
2-port OC3 POS SPA            1 POS SPA IOFPGA P1         3.4       0.0   
                              1 POS SPA IOFPGA P2         3.4       0.200
---------------------------- -- ---------------------- --------- ---------
4-port OC3 POS SPA            1 POS SPA IOFPGA P1         3.4       0.0   
                              1 POS SPA IOFPGA P2         3.4       0.200
---------------------------- -- ---------------------- --------- ---------
1-port OC12 POS SPA           1 POS SPA IOFPGA P1         3.4       0.0   
                              1 POS SPA IOFPGA P2         3.4       0.200
---------------------------- -- ---------------------- --------- ---------
2-port OC3 ATM SPA            1 KATM SPA IOFPGA           1.24      0.0   
---------------------------- -- ---------------------- --------- ---------
4-port OC3 ATM SPA            1 KATM SPA IOFPGA           1.24      0.0   
---------------------------- -- ---------------------- --------- ---------
1-port OC12 ATM SPA           1 KATM SPA IOFPGA           1.24      0.0   
---------------------------- -- ---------------------- --------- ---------
2G IPsec SPA                  1 PROM                      1.1       0.1   
                              2 LODI                      1.21      0.1   
                              3 Sequoia                   1.1       0.1   
---------------------------- -- ---------------------- --------- ---------
SIP-200                       1 SIP-200 I/O FPGA P1       1.1       0.100
                              1 SIP-200 I/O FPGA P4       1.1       0.400
                              1 SIP-200 I/O FPGA P6       1.1       0.600
                              2 SIP-200 EOS FPGA P1       0.27      0.100
                              2 SIP-200 EOS FPGA P450     1.211     0.450
                              2 SIP-200 EOS FPGA P5       0.27      0.500
                              2 SIP-200 EOS FPGA P550     1.211     0.550
                              2 SIP-200 EOS FPGA P6       1.211     0.600
                              3 SIP-200 PEG TX FPGA P1    1.129     0.100
                              3 SIP-200 PEG TX FPGA P6    1.129     0.600
                              4 SIP-200 PEG RX FPGA P1    1.3       0.100
                              4 SIP-200 PEG RX FPGA P4    1.3       0.400
                              4 SIP-200 PEG RX FPGA P6    1.3       0.600
                              5 SIP-200 ROMMON            1.2       0.100
---------------------------- -- ---------------------- --------- ---------
SIP-400                       1 SIP-400 ROMMON            1.1       0.1   
                              2 SIP-400 I/O FPGA          0.82      0.1   
                              3 SIP-400 SWITCH FPGA       0.25      0.1   
---------------------------- -- ---------------------- --------- ---------
SSC-600                       1 SSC-600 I/O FPGA          1.0       0.3   
                              2 SSC-600 DP RX FPGA        1.0       0.3   
                              3 SSC-600 DP TX FPGA P3     0.12288   0.3   
                              3 SSC-600 DP TX FPGA P4     0.16384   0.4   
                              3 SSC-600 DP TX FPGA P5     1.3       0.5   
                              4 SSC-600 ROMMON            1.2       0.3   
---------------------------- -- ---------------------- --------- ---------
CWPA2                         1 CWPA2 I/O FPGA P1         0.37      0.1   
                              1 CWPA2 I/O FPGA P7         0.39      2.0   
                              2 CWPA2 EOS FPGA P1         0.28      0.1   
                              2 CWPA2 EOS FPGA P7         0.47      2.0   
                              3 CWPA2 CPU0 ROMMON         1.2       0.1   
                              4 CWPA2 CPU1 ROMMON         1.2       0.1   
============================ =============================================

Release 12.2(18)SXE1 FPD Image Package Contents

This is the information displayed by the show upgrade fpd file c7600-fpd-pkg.122-18.SXE1.pkg command:

============================ =============================================
                                  Bundled FPD Image Version Matrix
                             =============================================
                                                                Min. Req.
Supported Card Types         ID  Image Name             Version  H/W Ver.
============================ == ====================== ========= =========
2-port T3/E3 Serial SPA       1 T3E3 SPA ROMMON           2.12      0.0   
                              2 T3E3 SPA I/O FPGA         0.24      0.0   
                              3 T3E3 SPA E3 FPGA          0.6       0.0   
                              4 T3E3 SPA T3 FPGA          0.14      0.0   
---------------------------- -- ---------------------- --------- ---------
4-port T3/E3 Serial SPA       1 T3E3 SPA ROMMON           2.12      0.0   
                              2 T3E3 SPA I/O FPGA         0.24      0.0   
                              3 T3E3 SPA E3 FPGA          0.6       0.0   
                              4 T3E3 SPA T3 FPGA          0.14      0.0   
---------------------------- -- ---------------------- --------- ---------
8-port Channelized T1/E1 SPA  1 CTE1 SPA ROMMON           2.12      0.140
                              1 CTE1 SPA ROMMON NP        2.12      0.0   
                              2 CTE1 SPA I/O FPGA         1.2       0.0   
---------------------------- -- ---------------------- --------- ---------
2-port Channelized T3 SPA     1 CT3 SPA ROMMON            2.12      0.100
                              2 CT3 SPA I/O FPGA          1.1       0.100
                              3 CT3 SPA T3 FPGA R1        0.11      0.100
                              3 CT3 SPA T3 FPGA R2        0.15      0.200
---------------------------- -- ---------------------- --------- ---------
4-port Channelized T3 SPA     1 CT3 SPA ROMMON            2.12      0.100
                              2 CT3 SPA I/O FPGA          1.1       0.100
                              3 CT3 SPA T3 FPGA R1        0.11      0.100
                              3 CT3 SPA T3 FPGA R2        0.15      0.200
---------------------------- -- ---------------------- --------- ---------
2-port OC3 POS SPA            1 POS SPA IOFPGA P1         3.4       0.0   
                              1 POS SPA IOFPGA P2         3.4       0.200
---------------------------- -- ---------------------- --------- ---------
4-port OC3 POS SPA            1 POS SPA IOFPGA P1         3.4       0.0   
                              1 POS SPA IOFPGA P2         3.4       0.200
---------------------------- -- ---------------------- --------- ---------
1-port OC12 POS SPA           1 POS SPA IOFPGA P1         3.4       0.0   
                              1 POS SPA IOFPGA P2         3.4       0.200
---------------------------- -- ---------------------- --------- ---------
2-port OC3 ATM SPA            1 KATM SPA IOFPGA           1.24      0.0   
---------------------------- -- ---------------------- --------- ---------
4-port OC3 ATM SPA            1 KATM SPA IOFPGA           1.24      0.0   
---------------------------- -- ---------------------- --------- ---------
1-port OC12 ATM SPA           1 KATM SPA IOFPGA           1.24      0.0   
---------------------------- -- ---------------------- --------- ---------
SIP-200                       1 SIP-200 I/O FPGA P1       1.1       0.100
                              1 SIP-200 I/O FPGA P4       1.1       0.400
                              1 SIP-200 I/O FPGA P6       1.1       0.600
                              2 SIP-200 EOS FPGA P1       0.27      0.100
                              2 SIP-200 EOS FPGA P450     1.211     0.450
                              2 SIP-200 EOS FPGA P5       0.27      0.500
                              2 SIP-200 EOS FPGA P550     1.211     0.550
                              2 SIP-200 EOS FPGA P6       1.211     0.600
                              3 SIP-200 PEG TX FPGA P1    1.129     0.100
                              3 SIP-200 PEG TX FPGA P6    1.129     0.600
                              4 SIP-200 PEG RX FPGA P1    1.3       0.100
                              4 SIP-200 PEG RX FPGA P4    1.3       0.400
                              4 SIP-200 PEG RX FPGA P6    1.3       0.600
                              5 SIP-200 ROMMON            1.2       0.100
---------------------------- -- ---------------------- --------- ---------
SIP-400                       1 SIP-400 ROMMON            1.1       0.1   
                              2 SIP-400 I/O FPGA          0.82      0.1   
                              3 SIP-400 SWITCH FPGA       0.25      0.1   
---------------------------- -- ---------------------- --------- ---------
CWPA2                         1 CWPA2 I/O FPGA P1         0.37      0.1   
                              2 CWPA2 EOS FPGA P1         0.28      0.1   
                              3 CWPA2 ROMMON              1.1       0.1   
============================ =============================================

FPD Upgrades


Note With Release 12.2(18)SXE2 and later releases, you do not need to do a separate FPD image upgrade for the Enhanced FlexWAN module, because the Cisco IOS software images contain the FPD image for the Enhanced FlexWAN module. The FPD image package also includes the FPD image for the Enhanced FlexWAN module. (CSCin90971)


See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/sipspasw/76fpdspa/index.htm

Cisco IOS Software Modularity

These sections describe Cisco IOS Software Modularity:

Cisco IOS Software Modularity Images

Cisco IOS Software Modularity Documentation

Cisco IOS Software Modularity Unsupported Features

Cisco IOS Software Modularity Images

See the "Supervisor Engine 720 Images in Release 12.2(18)SXF and Rebuilds" section and the "Supervisor Engine 32 Images in Release 12.2(18)SXF and Rebuilds" section for information about the Cisco IOS Software Modularity images.

Cisco IOS Software Modularity Documentation

See these publications for information about Cisco IOS Software Modularity:

Cisco IOS Software Modularity Installation and Configuration:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/122sxf18/mod_iosc.htm

Cisco IOS Software Modularity Command Reference:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/122sxf18/mod/index.htm

Embedded Event Manager:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/122sxf18/evnt_mgr/index.htm

Cisco IOS Software Modularity Unsupported Features

Cisco IOS Software Modularity does not support these features:

Hardware:

All Optical Services Modules (OSMs)

All SIPs and SPAs

ACE10-6500-K9 Application Control Engine (ACE) module

WS-SVC-ADM-1-K9 Traffic Anomaly Detector Module

WS-SVC-AGM-1-K9 Anomaly Guard Module

WS-SVC-AON-1-K9 Application-Oriented Networking (AON) Module

WS-SVC-CMM Communication Media Module

WS-SVC-CSG-1 Content Services Gateway (CSG) Module

WS-SVC-IPSEC-1 IPsec VPN Acceleration Services Module

WS-SVC-MWAM-1 Multi-Processor WAN Application Module

WS-SVC-PSD-1 Persistent Storage Device Module

WS-SVC-SSL-1 Secure Sockets Layer (SSL) Services Module

WS-SVC-WEBVPN-K9 WebVPN Services Module

WS-SVC-WLAN-1-K9 Wireless LAN service module

WS-X6066-SLB-S-K9 Content Switching Module with SSL (CSM-S)

In Release 12.2(18)SXF4, WS-SVC-WISM-1-K9 Wireless Services Module (WiSM)

Software:

IPv6 and all IPv6-related features

MPLS and all MPLS-related features

Bidirectional Forwarding Detection (BFD), Integrated IS-IS support for BFD over IPv4, and OSPF support for BFD over IPv4

Control Plane DSCP Support for RSVP

IDSM-2 EtherChannel load balancing

Integrated IS-IS Global Default Metric

RSVP Scalability Enhancements

In Release 12.2(18)SXF4, Multi-VRF (VRF Lite)

Feature Sets

These sections describe the feature sets in Release 12.2SX:

Feature Set Guidelines and Restrictions

Feature Set Descriptions

Feature Sets in Release 12.2(18)SXF

Feature Sets in Release 12.2(18)SXE and Rebuilds

Feature Sets in Release 12.2(18)SXD and Rebuilds

Feature Sets in Release 12.2(17d)SXB and Rebuilds

Feature Sets in Release 12.2(17b)SXA and Rebuilds (Deferred)

Feature Sets in Release 12.2(17a)SX and Rebuilds (Deferred)

Feature Sets in Release 12.2(14)SX and Rebuilds (Deferred)

Feature Set Guidelines and Restrictions

These are the feature set guidelines and restrictions:

There are no 12.2SX boot loader images: none are required.

The releases includes strong encryption images. Strong encryption images are subject to U.S. and local country export, import, and use laws. The country and class of end users eligible to receive and use Cisco encryption solutions are limited. See this publication for more information:

http://www.cisco.com/cgi-bin/Software/Crypto/crypto_main.pl

Many TFTP server implementations cannot transfer 16 MB or larger files. To transfer 16 MB or larger files, you might need to use FTP or rcp. See this online publication for procedures:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122cgcr/ffun_c/ffcprt2/fcf008.htm

These features are not supported in Release 12.2(18)SXD and later releases:

Apollo Domain

AppleTalk EIGRP

Banyan Vines

Exterior Gateway Protocol (EGP)

HP Probe

IEEE 802.10 VLANs

IGRP

LAN Extension

NetWare Asynchronous Services Interface (NASI)

Next Hop Resolution Protocol (NHRP) for IPX

Novell Link-State Protocol (NLSP)

Simple Multicast Routing Protocol (SMRP) for Appletalk

Xerox Network Systems (XNS)

Xremote

With releases earlier than Release 12.2(18)SXE, use of the EGP, BGP4, and IS-IS routing protocols requires the additional purchase of the InterDomain Routing Feature License (FR-IRC6), except when the price of the feature set already includes FR-IRC6.

In Release 12.2(17d)SXB and later releases, the price of any Cisco 7600 series router feature set (part numbers starting with "S763") includes FR-IRC6.

In Release 12.2(17b)SXA and later releases, the price of the "IP MPLS, IPv6, and BGP Feature Set" image (S733ZK9M-122* or S763ZK9M-122*) includes FR-IRC6.

Feature Set Descriptions

This section lists all of the features that are unique to each feature set and some of the features that are common to all feature sets. See the "New Features" section for a more complete list of supported features.

Feature Name
IP
Base
IP
Services
Advanced
IP Services
Enterprise
Services
Advanced
Enterprise
Services

Firewall Feature Set

Note Not required with the WS-SVC-FWM-1-K9 Firewall Services Module.

       
X

TCP Intercept

       
X

IPsec Network Security

Note

The SPA-IPSEC-2G and the IPsec VPN Acceleration Services Module support IPsec Network Security in hardware.

Without a SPA-IPSEC-2G or IPsec VPN Acceleration Services Module, the IPsec Network Security feature (configured with the crypto ipsec command) is supported in software only for administrative connections to Catalyst 6500 series switches and Cisco 7600 series routers.

   
X
 
X

MPLS (Search for "MPLS" in the "New Features" section for information about supported MPLS features.)

   
X
 
X

VPNs (Search for "VPN" in the "New Features" section for information about supported VPN features.)

   
X
 
X

DECNet

     
X
X

ISO CLNS

     
X
X

Novell IPX

     
X
X

IPv6 (Search for "IPv6" in the "New Features" section for information about supported IPv6 features.)

   
X
X
X

SLB (Search for "SLB" in the "New Features" section for information about supported SLB features.)

   
X
X
X

IS-IS

   
X
X
X

BGP4

 
X
X
X
X

MBGP

 
X
X
X
X

VRF Lite (Search for "VRF Lite" in the "New Features" section for information about supported VRF Lite features.)

 
X
X
X
X

Bidirectional PIM

 
X
X
X
X

EIGRP

 
X
X
X
X

MSDP

 
X
X
X
X

OSPF

 
X
X
X
X

PBR (Search for "PBR" in the "New Features" section for information about supported PBR features.)

 
X
X
X
X

NetFlow (Search for "NetFlow" in the "New Features" section for information about supported NetFlow features.)

X
X
X
X
X

EIGRP Stub Routing

X
X
X
X
X

HSRP

X
X
X
X
X

IGMP

X
X
X
X
X

IPsec Triple DES Encryption (3DES) for SSH

Note

The SSH k9 images support SSH 3DES access in software on the MSFC.

The k9 images in Release 12.2(17d)SXB and later releases support both SSHv2 server and SSHv2 client features.

The k9 images in releases earlier than Release 12.2(17d)SXB support only SSHv2 server features.

X
X
X
X
X

PIMv1, PIMv2 (Search for "PIM" in the "New Features" section for information about supported PIM features.)

X
X
X
X
X

RIPv1, RIPv2

X
X
X
X
X

Feature Sets in Release 12.2(18)SXF

These sections describe the feature sets in Release 12.2(18)SXF:

Supervisor Engine 720 Images in Release 12.2(18)SXF and Rebuilds

Supervisor Engine 32 Images in Release 12.2(18)SXF and Rebuilds

Supervisor Engine 2 Images in Release 12.2(18)SXF Rebuilds

Supervisor Engine 720 Images in Release 12.2(18)SXF and Rebuilds

These sections describe the Supervisor Engine 720 images:

Supervisor Engine 720 Advanced Enterprise Services Feature Set for Release 12.2(18)SXF and Rebuilds

Supervisor Engine 720 Enterprise Services for Release 12.2(18)SXF and Rebuilds

Supervisor Engine 720 Advanced IP Services Feature Set for Release 12.2(18)SXF and Rebuilds

Supervisor Engine 720 IP Services Feature Set for Release 12.2(18)SXF and Rebuilds


Note Release 12.2(18)SXF and later releases support the CompactFlash adapter and 512 MB CompactFlash card (WS-CF-UPG=), which replaces the 64 MB bootflash device.


Supervisor Engine 720 Advanced Enterprise Services Feature Set for Release 12.2(18)SXF and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s72033-adventerprisek9_wan-vz.122-18.SXF5 (88,334,992)
s72033-adventerprisek9_wan-vz.122-18.SXF4 (78,965,904)

Note This is a limited-access strong encryption image.

ADVANCED ENTERPRISE SERVICES SSH ( MODULAR)
CAT6000-SUP720/MSFC3: S733AEK9M-12218SXF

s72033-adventerprisek9_wan-mz.122-18.SXF5 (82,433,604)
s72033-adventerprisek9_wan-mz.122-18.SXF4 (76,971,076)
s72033-adventerprisek9_wan-mz.122-18.SXF3 (76,945,476)
s72033-adventerprisek9_wan-mz.122-18.SXF2 (76,913,220)
s72033-adventerprisek9_wan-mz.122-18.SXF1 (76,603,972)
s72033-adventerprisek9_wan-mz.122-18.SXF  (76,597,828)

Note This is a limited-access strong encryption image.

ADVANCED ENTERPRISE SERVICES SSH
CAT6000-SUP720/MSFC3: S733AEK9-12218SXF
7600-SUP720/MSFC3: S763AEK9-12218SXF


Supervisor Engine 720 Enterprise Services for Release 12.2(18)SXF and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s72033-entservicesk9_wan-vz.122-18.SXF5 (88,324,240)
s72033-entservicesk9_wan-vz.122-18.SXF4 (78,956,176)

Note This is a limited-access strong encryption image.

ENTERPRISE SERVICES SSH ( MODULAR)
CAT6000-SUP720/MSFC3: S733ESK9M-12218SXF

s72033-entservicesk9_wan-mz.122-18.SXF5 (81,680,932)
s72033-entservicesk9_wan-mz.122-18.SXF4 (76,220,452)
s72033-entservicesk9_wan-mz.122-18.SXF3 (76,190,756)
s72033-entservicesk9_wan-mz.122-18.SXF2 (76,159,524)
s72033-entservicesk9_wan-mz.122-18.SXF1 (75,852,836)
s72033-entservicesk9_wan-mz.122-18.SXF  (75,846,692)

Note This is a limited-access strong encryption image.

ENTERPRISE SERVICES SSH
CAT6000-SUP720/MSFC3: S733ESK9-12218SXF


Supervisor Engine 720 Advanced IP Services Feature Set for Release 12.2(18)SXF and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s72033-advipservicesk9_wan-vz.122-18.SXF5 (88,334,480)
s72033-advipservicesk9_wan-vz.122-18.SXF4 (78,958,736)

Note This is a limited-access strong encryption image.

IP SERVICES SSH ( MODULAR)
CAT6000-SUP720/MSFC3: S733AIK9M-12218SXF

s72033-advipservicesk9_wan-mz.122-18.SXF5 (82,434,084)
s72033-advipservicesk9_wan-mz.122-18.SXF4 (76,975,140)
s72033-advipservicesk9_wan-mz.122-18.SXF3 (76,943,908)
s72033-advipservicesk9_wan-mz.122-18.SXF2 (76,912,676)
s72033-advipservicesk9_wan-mz.122-18.SXF1 (76,603,428)
s72033-advipservicesk9_wan-mz.122-18.SXF  (76,599,844)

Note This is a limited-access strong encryption image.

ADVANCED IP SERVICES SSH
CAT6000-SUP720/MSFC3: S733AIK9-12218SXF
7600-SUP720/MSFC3: S763AIK9-12218SXF


Supervisor Engine 720 IP Services Feature Set for Release 12.2(18)SXF and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s72033-ipservicesk9_wan-vz.122-18.SXF5 (88,326,800)
s72033-ipservicesk9_wan-vz.122-18.SXF4 (78,955,664)

Note This is a limited-access strong encryption image.

IP SERVICES SSH ( MODULAR)
CAT6000-SUP720/MSFC3: S733ISK9M-12218SXF

s72033-ipservicesk9_wan-mz.122-18.SXF5 (81,681,412)
s72033-ipservicesk9_wan-mz.122-18.SXF4 (76,219,396)
s72033-ipservicesk9_wan-mz.122-18.SXF3 (76,192,772)
s72033-ipservicesk9_wan-mz.122-18.SXF2 (76,158,468)
s72033-ipservicesk9_wan-mz.122-18.SXF1 (75,851,780)
s72033-ipservicesk9_wan-mz.122-18.SXF  (75,847,684)

Note This is a limited-access strong encryption image.

IP SERVICES SSH
CAT6000-SUP720/MSFC3: S733ISK9-12218SXF
7600-SUP720/MSFC3: S763ISK9-12218SXF

s72033-ipservicesk9-vz.122-18.SXF5 (78,206,096)
s72033-ipservicesk9-vz.122-18.SXF4 (69,208,720)

Note This is a limited-access strong encryption image.

IP SERVICES SSH LAN ONLY ( MODULAR)
CAT6000-SUP720/MSFC3: S733ISK9N-12218SXF

s72033-ipservicesk9-mz.122-18.SXF5 (41,860,100)
s72033-ipservicesk9-mz.122-18.SXF4 (40,674,820)
s72033-ipservicesk9-mz.122-18.SXF3 (40,649,220)
s72033-ipservicesk9-mz.122-18.SXF2 (40,620,548)
s72033-ipservicesk9-mz.122-18.SXF1 (40,436,740)
s72033-ipservicesk9-mz.122-18.SXF  (40,432,132)

Note This is a limited-access strong encryption image.

IP SERVICES SSH LAN ONLY
CAT6000-SUP720/MSFC3: S733ISK9L-12218SXF

s72033-ipservices_wan-vz.122-18.SXF5 (86,173,840)
s72033-ipservices_wan-vz.122-18.SXF4 (76,898,448)

IP SERVICES ( MODULAR)
CAT6000-SUP720/MSFC3: S733ISM-12218SXF

s72033-ipservices_wan-mz.122-18.SXF5 (80,350,724)
s72033-ipservices_wan-mz.122-18.SXF4 (74,889,732)
s72033-ipservices_wan-mz.122-18.SXF3 (74,859,524)
s72033-ipservices_wan-mz.122-18.SXF2 (74,826,244)
s72033-ipservices_wan-mz.122-18.SXF1 (74,525,188)
s72033-ipservices_wan-mz.122-18.SXF  (74,519,556)

IP SERVICES
CAT6000-SUP720/MSFC3: S733IS-12218SXF
7600-SUP720/MSFC3: S763IS-12218SXF


Supervisor Engine 32 Images in Release 12.2(18)SXF and Rebuilds

These sections describe the Supervisor Engine 32 images:

Supervisor Engine 32 Advanced Enterprise Services Feature Set for Release 12.2(18)SXF and Rebuilds

Supervisor Engine 32 Enterprise Services for Release 12.2(18)SXF and Rebuilds

Supervisor Engine 32 Advanced IP Services Feature Set for Release 12.2(18)SXF and Rebuilds

Supervisor Engine 32 IP Services Feature Set for Release 12.2(18)SXF and Rebuilds

Supervisor Engine 32 IP Base Feature Set for Release 12.2(18)SXF and Rebuilds

Supervisor Engine 32 Advanced Enterprise Services Feature Set for Release 12.2(18)SXF and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s3223-adventerprisek9_wan-vz.122-18.SXF5 (54,924,944)

Note This is a limited-access strong encryption image.

ADVANCED ENTERPRISE SERVICES SSH ( MODULAR)
CAT6000-SUP32/MSFC2A: S323AEK9M-12218SXF

s3223-adventerprisek9_wan-mz.122-18.SXF5 (50,550,852)
s3223-adventerprisek9_wan-mz.122-18.SXF4 (47,386,180)
s3223-adventerprisek9_wan-mz.122-18.SXF3 (47,369,284)
s3223-adventerprisek9_wan-mz.122-18.SXF2 (47,351,876)
s3223-adventerprisek9_wan-mz.122-18.SXF  (47,114,308)

Note This is a limited-access strong encryption image.

ADVANCED ENTERPRISE SERVICES SSH
CAT6000-SUP32/MSFC2A: S323AEK9-12218SXF
7600-SUP32/MSFC2A: S7632AEK9-12218SXF


Supervisor Engine 32 Enterprise Services for Release 12.2(18)SXF and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s3223-entservicesk9_wan-vz.122-18.SXF5 (54,924,432)

Note This is a limited-access strong encryption image.

ENTERPRISE SERVICES SSH ( MODULAR)
CAT6000-SUP32/MSFC2A: S323ESK9M-12218SXF

s3223-entservicesk9_wan-mz.122-18.SXF5 (49,797,156)
s3223-entservicesk9_wan-mz.122-18.SXF4 (46,632,996)
s3223-entservicesk9_wan-mz.122-18.SXF3 (46,615,076)
s3223-entservicesk9_wan-mz.122-18.SXF2 (46,597,156)
s3223-entservicesk9_wan-mz.122-18.SXF  (46,363,172)

Note This is a limited-access strong encryption image.

ENTERPRISE SERVICES SSH
CAT6000-SUP32/MSFC2A: S323ESK9-12218SXF


Supervisor Engine 32 Advanced IP Services Feature Set for Release 12.2(18)SXF and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s3223-advipservicesk9_wan-vz.122-18.SXF5 (54,924,432)

Note This is a limited-access strong encryption image.

IP SERVICES SSH ( MODULAR)
CAT6000-SUP32/MSFC2A: S323AIK9M-12218SXF

s3223-advipservicesk9_wan-mz.122-18.SXF5 (50,549,284)
s3223-advipservicesk9_wan-mz.122-18.SXF4 (47,386,148)
s3223-advipservicesk9_wan-mz.122-18.SXF3 (47,367,716)
s3223-advipservicesk9_wan-mz.122-18.SXF2 (47,351,844)
s3223-advipservicesk9_wan-mz.122-18.SXF  (47,115,812)

Note This is a limited-access strong encryption image.

ADVANCED IP SERVICES SSH
CAT6000-SUP32/MSFC2A: S323AIK9-12218SXF
7600-SUP32/MSFC2A: S7632AIK9-12218SXF


Supervisor Engine 32 IP Services Feature Set for Release 12.2(18)SXF and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s3223-ipservicesk9_wan-vz.122-18.SXF5 (54,925,968)

Note This is a limited-access strong encryption image.

IP SERVICES SSH ( MODULAR)
CAT6000-SUP32/MSFC2A: S323ISK9M-12218SXF

s3223-ipservicesk9_wan-mz.122-18.SXF5 (49,796,612)
s3223-ipservicesk9_wan-mz.122-18.SXF4 (46,631,940)
s3223-ipservicesk9_wan-mz.122-18.SXF3 (46,615,556)
s3223-ipservicesk9_wan-mz.122-18.SXF2 (46,596,100)
s3223-ipservicesk9_wan-mz.122-18.SXF  (46,363,140)

Note This is a limited-access strong encryption image.

IP SERVICES SSH
CAT6000-SUP32/MSFC2A: S323ISK9-12218SXF
7600-SUP32/MSFC2A: S7632ISK9-12218SXF

s3223-ipservices_wan-vz.122-18.SXF5 (52,780,176)

IP SERVICES ( MODULAR)
7600-SUP32/MSFC2A: S323ISM-12218SXF

s3223-ipservices_wan-mz.122-18.SXF5 (48,463,876)
s3223-ipservices_wan-mz.122-18.SXF4 (45,302,276)
s3223-ipservices_wan-mz.122-18.SXF3 (45,279,236)
s3223-ipservices_wan-mz.122-18.SXF2 (45,266,436)
s3223-ipservices_wan-mz.122-18.SXF  (45,033,476)

IP SERVICES
7600-SUP32/MSFC2A: S7632IS-12218SXF


Supervisor Engine 32 IP Base Feature Set for Release 12.2(18)SXF and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s3223-ipbasek9_wan-vz.122-18.SXF5 (54,920,848)

Note This is a limited-access strong encryption image.

IP BASE SSH ( MODULAR)
CAT6000-SUP32/MSFC2A: S323IBK9M-12218SXF

s3223-ipbasek9_wan-mz.122-18.SXF5 (49,795,524)
s3223-ipbasek9_wan-mz.122-18.SXF4 (46,632,388)
s3223-ipbasek9_wan-mz.122-18.SXF3 (46,613,956)
s3223-ipbasek9_wan-mz.122-18.SXF2 (46,599,620)
s3223-ipbasek9_wan-mz.122-18.SXF  (46,362,564)

Note This is a limited-access strong encryption image.

IP BASE SSH
CAT6000-SUP32/MSFC2A: S323IBK9-12218SXF

s3223-ipbasek9-vz.122-18.SXF5 (48,991,888)

Note This is a limited-access strong encryption image.

IP BASE SSH LAN ONLY ( MODULAR)
CAT6000-SUP32/MSFC2A: S323IBK9LM-12218SXF

s3223-ipbasek9-mz.122-18.SXF5 (27,957,700)
s3223-ipbasek9-mz.122-18.SXF4 (27,463,108)
s3223-ipbasek9-mz.122-18.SXF3 (27,448,260)
s3223-ipbasek9-mz.122-18.SXF2 (27,433,412)
s3223-ipbasek9-mz.122-18.SXF  (27,267,012)

Note This is a limited-access strong encryption image.

IP BASE SSH LAN ONLY
CAT6000-SUP32/MSFC2A: S323IBK9L-12218SXF

s3223-ipbase_wan-vz.122-18.SXF5 (52,788,880)

IP BASE ( MODULAR)
CAT6000-SUP32/MSFC2A: S323IBM-12218SXF

s3223-ipbase_wan-mz.122-18.SXF5 (48,461,764)
s3223-ipbase_wan-mz.122-18.SXF4 (45,302,724)
s3223-ipbase_wan-mz.122-18.SXF3 (45,278,660)
s3223-ipbase_wan-mz.122-18.SXF2 (45,266,372)
s3223-ipbase_wan-mz.122-18.SXF  (45,032,388)

IP BASE
CAT6000-SUP32/MSFC2A: S323IB-12218SXF


Supervisor Engine 2 Images in Release 12.2(18)SXF Rebuilds

These sections describe the Supervisor Engine 2 images:

Supervisor Engine 2 Advanced Enterprise Services Feature Set for Release 12.2(18)SXF Rebuilds

Supervisor Engine 2 Enterprise Services for Release 12.2(18)SXF Rebuilds

Supervisor Engine 2 Advanced IP Services Feature Set for Release 12.2(18)SXF Rebuilds

Supervisor Engine 2 IP Services Feature Set for Release 12.2(18)SXF Rebuilds

Supervisor Engine 2 Advanced Enterprise Services Feature Set for Release 12.2(18)SXF Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s222-adventerprisek9_wan-mz.122-18.SXF5 (52,448,836)
s222-adventerprisek9_wan-mz.122-18.SXF4 (49,592,900)
s222-adventerprisek9_wan-mz.122-18.SXF3 (49,581,124)
s222-adventerprisek9_wan-mz.122-18.SXF2 (49,567,300)

Note This is a limited-access strong encryption image.

ADVANCED ENTERPRISE SERVICES SSH
CAT6000-SUP2/MSFC2: S222AEK9-12218SXF
7600-SUP2/MSFC2 S76AEK9-12218SXF


Supervisor Engine 2 Enterprise Services for Release 12.2(18)SXF Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s222-entservicesk9_wan-mz.122-18.SXF5 (51,696,164)
s222-entservicesk9_wan-mz.122-18.SXF4 (48,838,692)
s222-entservicesk9_wan-mz.122-18.SXF3 (48,828,452)
s222-entservicesk9_wan-mz.122-18.SXF2 (48,813,604)

Note This is a limited-access strong encryption image.

ENTERPRISE SERVICES SSH
CAT6000-SUP2/MSFC2: S222ESK9-12218SXF


Supervisor Engine 2 Advanced IP Services Feature Set for Release 12.2(18)SXF Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s222-advipservicesk9_wan-mz.122-18.SXF5 (52,448,804)
s222-advipservicesk9_wan-mz.122-18.SXF4 (49,592,356)
s222-advipservicesk9_wan-mz.122-18.SXF3 (49,581,604)
s222-advipservicesk9_wan-mz.122-18.SXF2 (49,566,756)

Note This is a limited-access strong encryption image.

ADVANCED IP SERVICES SSH
CAT6000-SUP2/MSFC2: S222AIK9-12218SXF
7600-SUP2/MSFC2 S76AIK9-12218SXF


Supervisor Engine 2 IP Services Feature Set for Release 12.2(18)SXF Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s222-ipservicesk9-mz.122-18.SXF5 (32,636,900)
s222-ipservicesk9-mz.122-18.SXF4 (31,973,348)
s222-ipservicesk9-mz.122-18.SXF3 (31,961,572)
s222-ipservicesk9-mz.122-18.SXF2 (31,949,284)

Note This is a limited-access strong encryption image.

IP SERVICES SSH LAN ONLY
CAT6000-SUP2/MSFC2: S222ISK9L-12218SXF

s222-ipservicesk9_wan-mz.122-18.SXF5 (51,696,132)
s222-ipservicesk9_wan-mz.122-18.SXF4 (48,837,124)
s222-ipservicesk9_wan-mz.122-18.SXF3 (48,828,420)
s222-ipservicesk9_wan-mz.122-18.SXF2 (48,814,596)

Note This is a limited-access strong encryption image.

IP SERVICES SSH
CAT6000-SUP2/MSFC2: S222ISK9-12218SXF
7600-SUP2/MSFC2 S76ISK9-12218SXF

s222-ipservices_wan-mz.122-18.SXF5 (50,390,020)
s222-ipservices_wan-mz.122-18.SXF4 (47,528,452)
s222-ipservices_wan-mz.122-18.SXF3 (47,516,676)
s222-ipservices_wan-mz.122-18.SXF2 (47,498,244)

IP SERVICES
CAT6000-SUP2/MSFC2: S222IS-12218SXF
7600-SUP2/MSFC2 S76IS-12218SXF


Feature Sets in Release 12.2(18)SXE and Rebuilds

These sections describe the feature sets in Release 12.2(18)SXE and rebuilds:

Advanced Enterprise Services SSH Feature Set for Release 12.2(18)SXE and Rebuilds

Enterprise Services SSH for Release 12.2(18)SXE and Rebuilds

Advanced IP Services SSH Feature Set for Release 12.2(18)SXE and Rebuilds

IP Services SSH Feature Set for Release 12.2(18)SXE and Rebuilds

FPD Image Packages

Advanced Enterprise Services SSH Feature Set for Release 12.2(18)SXE and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s72033-adventerprisek9_wan-mz.122-18.SXE6 (75,339,748)
s72033-adventerprisek9_wan-mz.122-18.SXE5 (75,309,540)
s72033-adventerprisek9_wan-mz.122-18.SXE4 (74,349,540)
s72033-adventerprisek9_wan-mz.122-18.SXE3 (74,272,228)
s72033-adventerprisek9_wan-mz.122-18.SXE2 (74,259,428)
s72033-adventerprisek9_wan-mz.122-18.SXE1 (73,019,364)
s72033-adventerprisek9_wan-mz.122-18.SXE  (deferred)

Note This is a limited-access strong encryption image.

ADVANCED ENTERPRISE SERVICES SSH
CAT6000-SUP720/MSFC3: S733AESK9-12218SXE
7600-SUP720/MSFC3: S763AESK9-12218SXE


Enterprise Services SSH for Release 12.2(18)SXE and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s72033-entservicesk9_wan-mz.122-18.SXE6 (75,339,236)
s72033-entservicesk9_wan-mz.122-18.SXE5 (75,309,028)
s72033-entservicesk9_wan-mz.122-18.SXE4 (74,351,076)
s72033-entservicesk9_wan-mz.122-18.SXE3 (74,273,252)
s72033-entservicesk9_wan-mz.122-18.SXE2 (74,259,428)
s72033-entservicesk9_wan-mz.122-18.SXE1 (73,019,364)

Note This is a limited-access strong encryption image.

ENTERPRISE SERVICES SSH
CAT6000-SUP720/MSFC3: S733ESK9-12218SXE


Advanced IP Services SSH Feature Set for Release 12.2(18)SXE and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s72033-advipservicesk9_wan-mz.122-18.SXE6 (75,339,748)
s72033-advipservicesk9_wan-mz.122-18.SXE5 (75,309,540)
s72033-advipservicesk9_wan-mz.122-18.SXE4 (74,349,028)
s72033-advipservicesk9_wan-mz.122-18.SXE3 (74,272,228)
s72033-advipservicesk9_wan-mz.122-18.SXE2 (74,259,428)
s72033-advipservicesk9_wan-mz.122-18.SXE1 (73,019,364)
s72033-advipservicesk9_wan-mz.122-18.SXE  (deferred)

Note This is a limited-access strong encryption image.

ADVANCED IP SERVICES SSH
CAT6000-SUP720/MSFC3: S733AISK9-12218SXE
7600-SUP720/MSFC3: S763AISK9-12218SXE


IP Services SSH Feature Set for Release 12.2(18)SXE and Rebuilds

Image Filename and Size in Bytes
Description, Platform, and Product ID

s72033-ipservicesk9_wan-mz.122-18.SXE6 (75,339,236)
s72033-ipservicesk9_wan-mz.122-18.SXE5 (75,309,028)
s72033-ipservicesk9_wan-mz.122-18.SXE4 (74,350,564)
s72033-ipservicesk9_wan-mz.122-18.SXE3 (74,273,252)
s72033-ipservicesk9_wan-mz.122-18.SXE2 (74,259,428)
s72033-ipservicesk9_wan-mz.122-18.SXE1 (73,019,364)

Note This is a limited-access strong encryption image.

IP SERVICES SSH
CAT6000-SUP720/MSFC3: S733IPSK9-12218SXE
7600-SUP720/MSFC3: S763IPSK9-12218SXE

s72033-ipservicesk9-mz.122-18.SXE6 (40,607,204)
s72033-ipservicesk9-mz.122-18.SXE5 (40,583,140)
s72033-ipservicesk9-mz.122-18.SXE4 (40,456,676)
s72033-ipservicesk9-mz.122-18.SXE3 (40,399,844)
s72033-ipservicesk9-mz.122-18.SXE2 (40,394,212)
s72033-ipservicesk9-mz.122-18.SXE1 (40,379,844)

Note This is a limited-access strong encryption image.

IP SERVICES SSH LAN ONLY
CAT6000-SUP720/MSFC3: S733IPLK9-12218SXE


Feature Sets in Release 12.2(18)SXD and Rebuilds

These sections describe the feature sets in Release 12.2(18)SXD and rebuilds:

Enterprise Firewall MPLS and IPv6 Feature Set for Release 12.2(18)SXD and Rebuilds

Enterprise IPv6 Feature Set for Release 12.2(18)SXD and Rebuilds

IP MPLS, IPv6, and BGP Feature Set for Release 12.2(18)SXD and Rebuilds

IP Feature Set for Release 12.2(18)SXD and Rebuilds

Enterprise Firewall MPLS and IPv6 Feature Set for Release 12.2(18)SXD and Rebuilds

Features

Supervisor Engine 720 Images

Supervisor Engine 2 Images

Features

MPLS

IPv6

Wire speed Layer 2 switching (bridging)

Wire speed Layer 3 switching (routing) for IP (routing protocols include RIPv1, RIPv2, OSPF, EIGRP, EGP, BGP4, and IS-IS; multicast routing protocols include PIM version 1 and 2, MBGP and MSDP, IGMP, and RGMP)

IPX routing in software on the MSFC

AppleTalk Phase 1 and 2, and DECnet Phase IV routing in software on the MSFC

DECnet Phase V and CLNS/OSI routing in software on the MSFC

Supervisor Engine 720 Images

Image Filename and Size in Bytes
Description, Platform, and Product ID
(Installed; append "=" for spare on shippable media.)

Supports OSM, FlexWAN, firewall, SSHv2, and 3DES:
s72033-jk9o3sv-mz.122-18.SXD7 (48,411,760)
s72033-jk9o3sv-mz.122-18.SXD6 (48,415,152)
s72033-jk9o3sv-mz.122-18.SXD5 (48,414,964)
s72033-jk9o3sv-mz.122-18.SXD4 (48,382,272)
s72033-jk9o3sv-mz.122-18.SXD3 (deferred)
s72033-jk9o3sv-mz.122-18.SXD2 (deferred)
s72033-jk9o3sv-mz.122-18.SXD1 (deferred)
s72033-jk9o3sv-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

ENT FW W/MPLS/IPV6/SSH/3DES:
S733AK9H-12218SXD (Catalyst 6500 series)
S763AK9H-12218SXD (Cisco 7600 series)


Supervisor Engine 2 Images

Image Filename and Size in Bytes
Description, Platform, and Product ID
(Installed; append "=" for spare on shippable media.)

Supports OSM, FlexWAN, firewall, SSHv2, and 3DES:
c6k222-jk9o3sv-mz.122-18.SXD7 (40,937,356)
c6k222-jk9o3sv-mz.122-18.SXD6 (40,939,140)
c6k222-jk9o3sv-mz.122-18.SXD5 (40,939,152)
c6k222-jk9o3sv-mz.122-18.SXD4 (40,913,596)
c6k222-jk9o3sv-mz.122-18.SXD3 (deferred)
c6k222-jk9o3sv-mz.122-18.SXD2 (deferred)
c6k222-jk9o3sv-mz.122-18.SXD1 (deferred)
c6k222-jk9o3sv-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

ENT FW W/MPLS/IPV6/SSH/3DES:
S222AK9H-12218SXD (Catalyst 6500 series)
S762AK9H-12218SXD (Cisco 7600 series)

Supports SSHv2 and 3DES:
c6k222-jk9s-mz.122-18.SXD7 (28,967,260)
c6k222-jk9s-mz.122-18.SXD6 (28,965,304)
c6k222-jk9s-mz.122-18.SXD5 (28,964,572)
c6k222-jk9s-mz.122-18.SXD4 (28,937,964)
c6k222-jk9s-mz.122-18.SXD3 (deferred)
c6k222-jk9s-mz.122-18.SXD2 (deferred)
c6k222-jk9s-mz.122-18.SXD1 (deferred)
c6k222-jk9s-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

ENT W/IPV6/SSH/3DES LAN ONLY:
S222ALK9-12218SXD (Catalyst 6500 series)

Supports OSM, FlexWAN, and firewall:
c6k222-jo3sv-mz.122-18.SXD7 (39,756,956)
c6k222-jo3sv-mz.122-18.SXD6 (39,756,624)
c6k222-jo3sv-mz.122-18.SXD5 (39,756,980)
c6k222-jo3sv-mz.122-18.SXD4 (39,731,780)
c6k222-jo3sv-mz.122-18.SXD3 (deferred)
c6k222-jo3sv-mz.122-18.SXD2 (deferred)
c6k222-jo3sv-mz.122-18.SXD1 (deferred)
c6k222-jo3sv-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

ENT FW W/MPLS/IPV6:
S222AH-12218SXD (Catalyst 6500 series)


Enterprise IPv6 Feature Set for Release 12.2(18)SXD and Rebuilds

Features

Supervisor Engine 720 Images

Supervisor Engine 2 Images

Features

IPv6

Wire speed Layer 2 switching (bridging)

Wire speed Layer 3 switching (routing) for IP (routing protocols include RIPv1, RIPv2, OSPF, EIGRP, EGP, BGP4, and IS-IS; multicast routing protocols include PIM version 1 and 2, MBGP and MSDP, IGMP, and RGMP)

IPX routing in software on the MSFC

AppleTalk Phase 1 and 2, and DECnet Phase IV routing in software on the MSFC

DECnet Phase V and CLNS/OSI routing in software on the MSFC

Supervisor Engine 720 Images

Image Filename and Size in Bytes
Description, Platform, and Product ID
(Installed; append "=" for spare on shippable media.)

Supports OSM, FlexWAN, SSHv2, and 3DES:
s72033-jk9sv-mz.122-18.SXD7 (48,213,556)
s72033-jk9sv-mz.122-18.SXD6 (48,215,464)
s72033-jk9sv-mz.122-18.SXD5 (48,215,488)
s72033-jk9sv-mz.122-18.SXD4 (48,191,764)
s72033-jk9sv-mz.122-18.SXD3 (deferred)
s72033-jk9sv-mz.122-18.SXD2 (deferred)
s72033-jk9sv-mz.122-18.SXD1 (deferred)
s72033-jk9sv-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

ENTERPRISE W/IPV6 W/SSH:
S733AK9-12218SXD (Catalyst 6500 series)

Supports SSHv2 and 3DES:
s72033-jk9s-mz.122-18.SXD7 (36,437,352)
s72033-jk9s-mz.122-18.SXD6 (36,434,492)
s72033-jk9s-mz.122-18.SXD5 (36,433,680)
s72033-jk9s-mz.122-18.SXD4 (36,408,484)
s72033-jk9s-mz.122-18.SXD3 (deferred)
s72033-jk9s-mz.122-18.SXD2 (deferred)
s72033-jk9s-mz.122-18.SXD1 (deferred)
s72033-jk9s-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

ENT. W/IPV6 W/SSH LAN ONLY:
S733ALK9-12218SXD (Catalyst 6500 series)


Supervisor Engine 2 Images

Image Filename and Size in Bytes
Description, Platform, and Product ID
(Installed; append "=" for spare on shippable media.)

Supports OSM, FlexWAN, SSHv2, and 3DES:
c6k222-jk9sv-mz.122-18.SXD7 (40,744,876)
c6k222-jk9sv-mz.122-18.SXD6 (40,746,196)
c6k222-jk9sv-mz.122-18.SXD5 (40,744,076)
c6k222-jk9sv-mz.122-18.SXD4 (40,718,164)
c6k222-jk9sv-mz.122-18.SXD3 (deferred)
c6k222-jk9sv-mz.122-18.SXD2 (deferred)
c6k222-jk9sv-mz.122-18.SXD1 (deferred)
c6k222-jk9sv-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

ENT W/IPV6/SSH/3DES:
S222AK9-12218SXD (Catalyst 6500 series)

Supports OSM and FlexWAN:
c6k222-jsv-mz.122-18.SXD7 (39,563,340)
c6k222-jsv-mz.122-18.SXD6 (39,563,796)
c6k222-jsv-mz.122-18.SXD5 (39,564,244)
c6k222-jsv-mz.122-18.SXD4 (39,539,568)
c6k222-jsv-mz.122-18.SXD3 (deferred)
c6k222-jsv-mz.122-18.SXD2 (deferred)
c6k222-jsv-mz.122-18.SXD1 (deferred)
c6k222-jsv-mz.122-18.SXD  (deferred)

ENT W/IPV6:
S222A-12218SXD (Catalyst 6500 series)


IP MPLS, IPv6, and BGP Feature Set for Release 12.2(18)SXD and Rebuilds

Features

Supervisor Engine 720 Images

Supervisor Engine 2 Images

Features

MPLS

IPv6

Wire speed Layer 2 switching (bridging)

Wire speed Layer 3 switching (routing) for IP (routing protocols include RIPv1, RIPv2, OSPF, EIGRP, EGP, BGP4, and IS-IS; multicast routing protocols include PIM version 1 and 2, MBGP and MSDP, IGMP, and RGMP)

Supervisor Engine 720 Images

Image Filename and Size in Bytes
Description, Platform, and Product ID
(Installed; append "=" for spare on shippable media.)

Supports OSM, FlexWAN, SSHv2, and 3DES:
s72033-pk9sv-mz.122-18.SXD7 (46,660,652)
s72033-pk9sv-mz.122-18.SXD6 (46,658,960)
s72033-pk9sv-mz.122-18.SXD5 (46,656,764)
s72033-pk9sv-mz.122-18.SXD4 (46,633,792)
s72033-pk9sv-mz.122-18.SXD3 (deferred)
s72033-pk9sv-mz.122-18.SXD2 (deferred)
s72033-pk9sv-mz.122-18.SXD1 (deferred)
s72033-pk9sv-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

ADV IP W/MPLS/IPV6/SSH/3DES + BGP:
S733ZK9M-12218SXD (Catalyst 6500 series)
S763ZK9M-12218SXD (Cisco 7600 series)


Supervisor Engine 2 Images

Image Filename and Size in Bytes
Description, Platform, and Product ID
(Installed; append "=" for spare on shippable media.)

Supports OSM, FlexWAN, SSHv2, and 3DES:
c6k222-pk9sv-mz.122-18.SXD7 (39,455,296)
c6k222-pk9sv-mz.122-18.SXD6 (39,457,416)
c6k222-pk9sv-mz.122-18.SXD5 (39,457,356)
c6k222-pk9sv-mz.122-18.SXD4 (39,433,116)
c6k222-pk9sv-mz.122-18.SXD3 (deferred)
c6k222-pk9sv-mz.122-18.SXD2 (deferred)
c6k222-pk9sv-mz.122-18.SXD1 (deferred)
c6k222-pk9sv-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

ADV IP W/MPLS/IPV6/SSH/3DES + BGP:
S222ZK9M-12218SXD (Catalyst 6500 series)
S762ZK9M-12218SXD (Cisco 7600 series)


IP Feature Set for Release 12.2(18)SXD and Rebuilds

Features

Supervisor Engine 720 Images

Supervisor Engine 2 Images

Features

Wire speed Layer 2 switching (bridging)

Wire speed Layer 3 switching (routing) for IP (routing protocols include RIPv1, RIPv2, OSPF, EIGRP, EGP, BGP4, and IS-IS; multicast routing protocols include PIM version 1 and 2, MBGP and MSDP, IGMP, and RGMP)

Supervisor Engine 720 Images

Image Filename and Size in Bytes
Description, Platform, and Product ID
(Installed; append "=" for spare on shippable media.)

Supports OSM, FlexWAN, SSHv2, and 3DES:
s72033-pk9sv-mz.122-18.SXD7 (46,660,652)
s72033-pk9sv-mz.122-18.SXD6 (46,658,960)
s72033-pk9sv-mz.122-18.SXD5 (46,656,764)
s72033-pk9sv-mz.122-18.SXD4 (46,633,792)
s72033-pk9sv-mz.122-18.SXD3 (deferred)
s72033-pk9sv-mz.122-18.SXD2 (deferred)
s72033-pk9sv-mz.122-18.SXD1 (deferred)
s72033-pk9sv-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

IP W/SSH/3DES:
S733ZK9-12218SXD (Catalyst 6500 series)
S763ZK9-12218SXD (Cisco 7600 series)

Supports SSHv2 and 3DES:
s72033-pk9s-mz.122-18.SXD7 (34,883,700)
s72033-pk9s-mz.122-18.SXD6 (34,878,116)
s72033-pk9s-mz.122-18.SXD5 (34,876,048)
s72033-pk9s-mz.122-18.SXD4 (34,853,900)
s72033-pk9s-mz.122-18.SXD3 (deferred)
s72033-pk9s-mz.122-18.SXD2 (deferred)
s72033-pk9s-mz.122-18.SXD1 (deferred)
s72033-pk9s-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

IP W/SSH/3DES LAN ONLY:
S733ZLK9-12218SXD (Catalyst 6500 series)

Supports OSM and FlexWAN:
s72033-psv-mz.122-18.SXD7 (45,463,592)
s72033-psv-mz.122-18.SXD6 (45,465,840)
s72033-psv-mz.122-18.SXD5 (45,465,300)
s72033-psv-mz.122-18.SXD4 (45,443,036)
s72033-psv-mz.122-18.SXD3 (deferred)
s72033-psv-mz.122-18.SXD2 (deferred)
s72033-psv-mz.122-18.SXD1 (deferred)
s72033-psv-mz.122-18.SXD  (deferred)

IP:
S733Z-12218SXD (Catalyst 6500 series)
S763Z-12218SXD (Cisco 7600 series)


s72033-ps-mz.122-18.SXD7 (33,956,572)
s72033-ps-mz.122-18.SXD6 (33,956,684)
s72033-ps-mz.122-18.SXD5 (33,953,304)
s72033-ps-mz.122-18.SXD4 (33,927,520)
s72033-ps-mz.122-18.SXD3 (deferred)
s72033-ps-mz.122-18.SXD2 (deferred)
s72033-ps-mz.122-18.SXD1 (deferred)
s72033-ps-mz.122-18.SXD  (deferred)

IP LAN ONLY:
S733ZL-12218SXD (Catalyst 6500 series)


Supervisor Engine 2 Images

Image Filename and Size in Bytes
Description, Platform, and Product ID
(Installed; append "=" for spare on shippable media.)

Supports OSM, FlexWAN, SSHv2, and 3DES:
c6k222-pk9sv-mz.122-18.SXD7 (39,455,296)
c6k222-pk9sv-mz.122-18.SXD6 (39,457,416)
c6k222-pk9sv-mz.122-18.SXD5 (39,457,356)
c6k222-pk9sv-mz.122-18.SXD4 (39,433,116)
c6k222-pk9sv-mz.122-18.SXD3 (deferred)
c6k222-pk9sv-mz.122-18.SXD2 (deferred)
c6k222-pk9sv-mz.122-18.SXD1 (deferred)
c6k222-pk9sv-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

IP W/SSH/3DES:
S222ZK9-12218SXD (Catalyst 6500 series)
S762ZK9-12218SXD (Cisco 7600 series)

Supports SSHv2 and 3DES:
c6k222-pk9s-mz.122-18.SXD7 (27,676,528)
c6k222-pk9s-mz.122-18.SXD6 (27,674,272)
c6k222-pk9s-mz.122-18.SXD5 (27,674,940)
c6k222-pk9s-mz.122-18.SXD4 (27,650,864)
c6k222-pk9s-mz.122-18.SXD3 (deferred)
c6k222-pk9s-mz.122-18.SXD2 (deferred)
c6k222-pk9s-mz.122-18.SXD1 (deferred)
c6k222-pk9s-mz.122-18.SXD  (deferred)

Note This is a limited-access strong encryption image.

IP W/SSH/3DES LAN ONLY:
S222ZLK9-12218SXD (Catalyst 6500 series)

Supports OSM and FlexWAN:
c6k222-psv-mz.122-18.SXD7 (38,277,828)
c6k222-psv-mz.122-18.SXD6 (38,278,260)
c6k222-psv-mz.122-18.SXD5 (38,278,572)
c6k222-psv-mz.122-18.SXD4 (38,254,300)
c6k222-psv-mz.122-18.SXD3 (deferred)
c6k222-psv-mz.122-18.SXD2 (deferred)
c6k222-psv-mz.122-18.SXD1 (deferred)
c6k222-psv-mz.122-18.SXD  (deferred)

IP:
S222Z-12218SXD (Catalyst 6500 series)
S762Z-12218SXD (Cisco 7600 series)


c6k222-ps-mz.122-18.SXD7 (26,498,168)
c6k222-ps-mz.122-18.SXD6 (26,498,412)
c6k222-ps-mz.122-18.SXD5 (26,496,384)
c6k222-ps-mz.122-18.SXD4 (26,471,648)
c6k222-ps-mz.122-18.SXD3 (deferred)
c6k222-ps-mz.122-18.SXD2 (deferred)
c6k222-ps-mz.122-18.SXD1 (deferred)
c6k222-ps-mz.122-18.SXD  (deferred)

IP LAN ONLY:
S222ZL-12218SXD (Catalyst 6500 series)


Feature Sets in Release 12.2(17d)SXB and Rebuilds

These sections describe the feature sets in Release 12.2(17d)SXB and rebuilds:

Enterprise Firewall MPLS and IPv6 Feature Set for Release 12.2(17d)SXB and Rebuilds

Enterprise IPv6 Feature Set for Release 12.2(17d)SXB and Rebuilds

IP MPLS, IPv6, and BGP Feature Set for Release 12.2(17d)SXB and Rebuilds

IP Feature Set for Release 12.2(17d)SXB and Rebuilds

Enterprise Firewall MPLS and IPv6 Feature Set for Release 12.2(17d)SXB and Rebuilds

Features

Supervisor Engine 720 Images

Supervisor Engine 2 Images

Features

MPLS

IPv6

Wire speed Layer 2 switching (bridging)

Wire speed Layer 3 switching (routing) for IP (routing protocols include RIPv1, RIPv2, OSPF, IGRP, EIGRP, EGP, BGP4, and IS-IS; multicast routing protocols include PIM version 1 and 2, MBGP and MSDP, IGMP, and RGMP)

IPX routing in software on the MSFC

AppleTalk Phase 1 and 2, DECnet Phase IV, and VINES routing in software on the MSFC

DECnet Phase V and CLNS/OSI routing in software on the MSFC

Supervisor Engine 720 Images

Image Filename and Size in Bytes
Description, Product ID, and Platform
(Installed; append "=" for spare on shippable media.)

s72033-jk9o3sv-mz.122-17d.SXB11a (43,880,568)
s72033-jk9o3sv-mz.122-17d.SXB11 (43,810,240)
s72033-jk9o3sv-mz.122-17d.SXB10 (43,818,816)
s72033-jk9o3sv-mz.122-17d.SXB9  (43,799,804)
s72033-jk9o3sv-mz.122-17d.SXB8  (43,760,344)
s72033-jk9o3sv-mz.122-17d.SXB7 (deferred)
s72033-jk9o3sv-mz.122-17d.SXB6 (deferred)
s72033-jk9o3sv-mz.122-17d.SXB5 (deferred)
s72033-jk9o3sv-mz.122-17d.SXB4 (deferred)
s72033-jk9o3sv-mz.122-17d.SXB3 (deferred)
s72033-jk9o3sv-mz.122-17d.SXB2 (deferred)
s72033-jk9o3sv-mz.122-17d.SXB1 (deferred)
s72033-jk9o3sv-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

ENT FW W/MPLS/IPV6/SSH/3DES:
S733AK9H-12217SXB (Catalyst 6500 series)
S763AK9H-12217SXB (Cisco 7600 series)


Supervisor Engine 2 Images

Image Filename and Size in Bytes
Description, Product ID, and Platform
(Installed; append "=" for spare on shippable media.)

c6k222-jk9o3sv-mz.122-17d.SXB11a (37,685,844)
c6k222-jk9o3sv-mz.122-17d.SXB11 (37,673,212)
c6k222-jk9o3sv-mz.122-17d.SXB10 (37,681,184)
c6k222-jk9o3sv-mz.122-17d.SXB9  (37,664,684)
c6k222-jk9o3sv-mz.122-17d.SXB8  (37,640,496)
c6k222-jk9o3sv-mz.122-17d.SXB7 (deferred)
c6k222-jk9o3sv-mz.122-17d.SXB6 (deferred)
c6k222-jk9o3sv-mz.122-17d.SXB5 (deferred)
c6k222-jk9o3sv-mz.122-17d.SXB4 (deferred)
c6k222-jk9o3sv-mz.122-17d.SXB3 (deferred)
c6k222-jk9o3sv-mz.122-17d.SXB2 (deferred)
c6k222-jk9o3sv-mz.122-17d.SXB1 (deferred)
c6k222-jk9o3sv-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

ENT FW W/MPLS/IPV6/SSH/3DES:
S222AK9H-12217SXB (Catalyst 6500 series)
S762AK9H-12217SXB (Cisco 7600 series)

c6k222-jk9s-mz.122-17d.SXB11a (26,891,604)
c6k222-jk9s-mz.122-17d.SXB11 (26,881,824)
c6k222-jk9s-mz.122-17d.SXB10 (26,891,068)
c6k222-jk9s-mz.122-17d.SXB9  (26,877,532)
c6k222-jk9s-mz.122-17d.SXB8  (26,851,208)
c6k222-jk9s-mz.122-17d.SXB7 (deferred)
c6k222-jk9s-mz.122-17d.SXB6 (deferred)
c6k222-jk9s-mz.122-17d.SXB5 (deferred)
c6k222-jk9s-mz.122-17d.SXB4 (deferred)
c6k222-jk9s-mz.122-17d.SXB3 (deferred)
c6k222-jk9s-mz.122-17d.SXB2 (deferred)
c6k222-jk9s-mz.122-17d.SXB1 (deferred)
c6k222-jk9s-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

ENT W/IPV6/SSH/3DES LAN ONLY:
S222ALK9-12217SXB (Catalyst 6500 series)

c6k222-jo3sv-mz.122-17d.SXB11a (36,415,936)
c6k222-jo3sv-mz.122-17d.SXB11 (36,403,784)
c6k222-jo3sv-mz.122-17d.SXB10 (36,409,760)
c6k222-jo3sv-mz.122-17d.SXB9  (36,395,956)
c6k222-jo3sv-mz.122-17d.SXB8  (36,368,352)
c6k222-jo3sv-mz.122-17d.SXB7 (deferred)
c6k222-jo3sv-mz.122-17d.SXB6 (deferred)
c6k222-jo3sv-mz.122-17d.SXB5 (deferred)
c6k222-jo3sv-mz.122-17d.SXB4 (deferred)
c6k222-jo3sv-mz.122-17d.SXB3 (deferred)
c6k222-jo3sv-mz.122-17d.SXB2 (deferred)
c6k222-jo3sv-mz.122-17d.SXB1 (deferred)
c6k222-jo3sv-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

ENT FW W/MPLS/IPV6:
S222AH-12217SXB (Catalyst 6500 series)


Enterprise IPv6 Feature Set for Release 12.2(17d)SXB and Rebuilds

Features

Supervisor Engine 720 Images

Supervisor Engine 2 Images

Features

IPv6

Wire speed Layer 2 switching (bridging)

Wire speed Layer 3 switching (routing) for IP (routing protocols include RIPv1, RIPv2, OSPF, IGRP, EIGRP, EGP, BGP4, and IS-IS; multicast routing protocols include PIM version 1 and 2, MBGP and MSDP, IGMP, and RGMP)

IPX routing in software on the MSFC

AppleTalk Phase 1 and 2, DECnet Phase IV, and VINES routing in software on the MSFC

DECnet Phase V and CLNS/OSI routing in software on the MSFC

Supervisor Engine 720 Images

Image Filename and Size in Bytes
Description, Product ID, and Platform
(Installed; append "=" for spare on shippable media.)

s72033-jk9sv-mz.122-17d.SXB11a (43,690,324)
s72033-jk9sv-mz.122-17d.SXB11 (43,619,424)
s72033-jk9sv-mz.122-17d.SXB10 (43,626,788)
s72033-jk9sv-mz.122-17d.SXB9  (43,610,624)
s72033-jk9sv-mz.122-17d.SXB8  (43,569,316)
s72033-jk9sv-mz.122-17d.SXB7 (deferred)
s72033-jk9sv-mz.122-17d.SXB6 (deferred)
s72033-jk9sv-mz.122-17d.SXB5 (deferred)
s72033-jk9sv-mz.122-17d.SXB4 (deferred)
s72033-jk9sv-mz.122-17d.SXB3 (deferred)
s72033-jk9sv-mz.122-17d.SXB2 (deferred)
s72033-jk9sv-mz.122-17d.SXB1 (deferred)
s72033-jk9sv-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

ENTERPRISE W/IPV6 W/SSH:
S733AK9-12217SXB (Catalyst 6500 series)

s72033-jk9s-mz.122-17d.SXB11a (33,088,544)
s72033-jk9s-mz.122-17d.SXB11 (33,016,328)
s72033-jk9s-mz.122-17d.SXB10 (33,025,852)
s72033-jk9s-mz.122-17d.SXB9  (33,011,016)
s72033-jk9s-mz.122-17d.SXB8  (32,970,964)
s72033-jk9s-mz.122-17d.SXB7 (deferred)
s72033-jk9s-mz.122-17d.SXB6 (deferred)
s72033-jk9s-mz.122-17d.SXB5 (deferred)
s72033-jk9s-mz.122-17d.SXB4 (deferred)
s72033-jk9s-mz.122-17d.SXB3 (deferred)
s72033-jk9s-mz.122-17d.SXB2 (deferred)
s72033-jk9s-mz.122-17d.SXB1 (deferred)
s72033-jk9s-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

ENT. W/IPV6 W/SSH LAN ONLY:
S733ALK9-12217SXB (Catalyst 6500 series)


Supervisor Engine 2 Images

Image Filename and Size in Bytes
Description, Product ID, and Platform
(Installed; append "=" for spare on shippable media.)

c6k222-jk9sv-mz.122-17d.SXB11a (37,493,056)
c6k222-jk9sv-mz.122-17d.SXB11 (37,483,068)
c6k222-jk9sv-mz.122-17d.SXB10 (37,489,204)
c6k222-jk9sv-mz.122-17d.SXB9  (37,475,792)
c6k222-jk9sv-mz.122-17d.SXB8  (37,447,880)
c6k222-jk9sv-mz.122-17d.SXB7 (deferred)
c6k222-jk9sv-mz.122-17d.SXB6 (deferred)
c6k222-jk9sv-mz.122-17d.SXB5 (deferred)
c6k222-jk9sv-mz.122-17d.SXB4 (deferred)
c6k222-jk9sv-mz.122-17d.SXB3 (deferred)
c6k222-jk9sv-mz.122-17d.SXB2 (deferred)
c6k222-jk9sv-mz.122-17d.SXB1 (deferred)
c6k222-jk9sv-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

ENT W/IPV6/SSH/3DES:
S222AK9-12217SXB (Catalyst 6500 series)

c6k222-jsv-mz.122-17d.SXB11a (36,222,792)
c6k222-jsv-mz.122-17d.SXB11 (36,211,152)
c6k222-jsv-mz.122-17d.SXB10 (36,222,496)
c6k222-jsv-mz.122-17d.SXB9  (36,204,308)
c6k222-jsv-mz.122-17d.SXB8  (36,180,896)
c6k222-jsv-mz.122-17d.SXB7 (deferred)
c6k222-jsv-mz.122-17d.SXB6 (deferred)
c6k222-jsv-mz.122-17d.SXB5 (deferred)
c6k222-jsv-mz.122-17d.SXB4 (deferred)
c6k222-jsv-mz.122-17d.SXB3 (deferred)
c6k222-jsv-mz.122-17d.SXB2 (deferred)
c6k222-jsv-mz.122-17d.SXB1 (deferred)
c6k222-jsv-mz.122-17d.SXB  (deferred)

ENT W/IPV6:
S222A-12217SXB (Catalyst 6500 series)


IP MPLS, IPv6, and BGP Feature Set for Release 12.2(17d)SXB and Rebuilds

Features

Supervisor Engine 720 Images

Supervisor Engine 2 Images

Features

Includes FR-IRC6

MPLS

IPv6

Wire speed Layer 2 switching (bridging)

Wire speed Layer 3 switching (routing) for IP (routing protocols include RIPv1, RIPv2, OSPF, IGRP, EIGRP, EGP, BGP4, and IS-IS; multicast routing protocols include PIM version 1 and 2, MBGP and MSDP, IGMP, and RGMP)

Supervisor Engine 720 Images

Image Filename and Size in Bytes
Description, Product ID, and Platform
(Installed; append "=" for spare on shippable media.)

s72033-pk9sv-mz.122-17d.SXB11a (42,131,936)
s72033-pk9sv-mz.122-17d.SXB11 (42,061,544)
s72033-pk9sv-mz.122-17d.SXB10 (42,066,736)
s72033-pk9sv-mz.122-17d.SXB9  (42,050,492)
s72033-pk9sv-mz.122-17d.SXB8  (42,007,568)
s72033-pk9sv-mz.122-17d.SXB7 (deferred)
s72033-pk9sv-mz.122-17d.SXB6 (deferred)
s72033-pk9sv-mz.122-17d.SXB5 (deferred)
s72033-pk9sv-mz.122-17d.SXB4 (deferred)
s72033-pk9sv-mz.122-17d.SXB3 (deferred)
s72033-pk9sv-mz.122-17d.SXB2 (deferred)
s72033-pk9sv-mz.122-17d.SXB1 (deferred)
s72033-pk9sv-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

ADV IP W/MPLS/IPV6/SSH/3DES + BGP:
S733ZK9M-12217SXB (Catalyst 6500 series)
S763ZK9M-12217SXB (Cisco 7600 series)


Supervisor Engine 2 Images

Image Filename and Size in Bytes
Description, Product ID, and Platform
(Installed; append "=" for spare on shippable media.)

c6k222-pk9sv-mz.122-17d.SXB11a (36,201,004)
c6k222-pk9sv-mz.122-17d.SXB11 (36,192,332)
c6k222-pk9sv-mz.122-17d.SXB10 (36,199,852)
c6k222-pk9sv-mz.122-17d.SXB9  (36,183,184)
c6k222-pk9sv-mz.122-17d.SXB8  (36,158,288)
c6k222-pk9sv-mz.122-17d.SXB7 (deferred)
c6k222-pk9sv-mz.122-17d.SXB6 (deferred)
c6k222-pk9sv-mz.122-17d.SXB5 (deferred)
c6k222-pk9sv-mz.122-17d.SXB4 (deferred)
c6k222-pk9sv-mz.122-17d.SXB3 (deferred)
c6k222-pk9sv-mz.122-17d.SXB2 (deferred)
c6k222-pk9sv-mz.122-17d.SXB1 (deferred)
c6k222-pk9sv-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

ADV IP W/MPLS/IPV6/SSH/3DES + BGP:
S222ZK9M-12217SXB (Catalyst 6500 series)
S762ZK9M-12217SXB (Cisco 7600 series)


IP Feature Set for Release 12.2(17d)SXB and Rebuilds

Features

Supervisor Engine 720 Images

Supervisor Engine 2 Images

Features

Wire speed Layer 2 switching (bridging)

Wire speed Layer 3 switching (routing) for IP (routing protocols include RIPv1, RIPv2, OSPF, IGRP, EIGRP, EGP, BGP4, and IS-IS; multicast routing protocols include PIM version 1 and 2, MBGP and MSDP, IGMP, and RGMP)

Supervisor Engine 720 Images

Image Filename and Size in Bytes
Description, Product ID, and Platform
(Installed; append "=" for spare on shippable media.)

s72033-pk9sv-mz.122-17d.SXB11a (42,131,936)
s72033-pk9sv-mz.122-17d.SXB11 (42,061,544)
s72033-pk9sv-mz.122-17d.SXB10 (42,066,736)
s72033-pk9sv-mz.122-17d.SXB9  (42,050,492)
s72033-pk9sv-mz.122-17d.SXB8  (42,007,568)
s72033-pk9sv-mz.122-17d.SXB7 (deferred)
s72033-pk9sv-mz.122-17d.SXB6 (deferred)
s72033-pk9sv-mz.122-17d.SXB5 (deferred)
s72033-pk9sv-mz.122-17d.SXB4 (deferred)
s72033-pk9sv-mz.122-17d.SXB3 (deferred)
s72033-pk9sv-mz.122-17d.SXB2 (deferred)
s72033-pk9sv-mz.122-17d.SXB1 (deferred)
s72033-pk9sv-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

IP W/SSH/3DES:
S733ZK9-12217SXB (Catalyst 6500 series)
S763ZK9-12217SXB (Cisco 7600 series)

s72033-pk9s-mz.122-17d.SXB11a (31,530,692)
s72033-pk9s-mz.122-17d.SXB11 (31,460,688)
s72033-pk9s-mz.122-17d.SXB10 (31,467,692)
s72033-pk9s-mz.122-17d.SXB9  (31,451,440)
s72033-pk9s-mz.122-17d.SXB8  (31,409,268)
s72033-pk9s-mz.122-17d.SXB7 (deferred)
s72033-pk9s-mz.122-17d.SXB6 (deferred)
s72033-pk9s-mz.122-17d.SXB5 (deferred)
s72033-pk9s-mz.122-17d.SXB4 (deferred)
s72033-pk9s-mz.122-17d.SXB3 (deferred)
s72033-pk9s-mz.122-17d.SXB2 (deferred)
s72033-pk9s-mz.122-17d.SXB1 (deferred)
s72033-pk9s-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

IP W/SSH/3DES LAN ONLY:
S733ZLK9-12217SXB (Catalyst 6500 series)

s72033-psv-mz.122-17d.SXB11a (41,123,924)
s72033-psv-mz.122-17d.SXB11 (41,050,516)
s72033-psv-mz.122-17d.SXB10 (41,056,568)
s72033-psv-mz.122-17d.SXB9  (41,043,144)
s72033-psv-mz.122-17d.SXB8  (41,002,792)
s72033-psv-mz.122-17d.SXB7 (deferred)
s72033-psv-mz.122-17d.SXB6 (deferred)
s72033-psv-mz.122-17d.SXB5 (deferred)
s72033-psv-mz.122-17d.SXB4 (deferred)
s72033-psv-mz.122-17d.SXB3 (deferred)
s72033-psv-mz.122-17d.SXB2 (deferred)
s72033-psv-mz.122-17d.SXB1 (deferred)
s72033-psv-mz.122-17d.SXB  (deferred)

IP:
S733Z-12217SXB (Catalyst 6500 series)
S763Z-12217SXB (Cisco 7600 series)

s72033-ps-mz.122-17d.SXB11a (30,785,656)
s72033-ps-mz.122-17d.SXB11 (30,713,804)
s72033-ps-mz.122-17d.SXB10 (30,725,328)
s72033-ps-mz.122-17d.SXB9  (30,709,512)
s72033-ps-mz.122-17d.SXB8  (30,670,748)
s72033-ps-mz.122-17d.SXB7 (deferred)
s72033-ps-mz.122-17d.SXB6 (deferred)
s72033-ps-mz.122-17d.SXB5 (deferred)
s72033-ps-mz.122-17d.SXB4 (deferred)
s72033-ps-mz.122-17d.SXB3 (deferred)
s72033-ps-mz.122-17d.SXB2 (deferred)
s72033-ps-mz.122-17d.SXB1 (deferred)
s72033-ps-mz.122-17d.SXB  (deferred)

IP LAN ONLY:
S733ZL-12217SXB (Catalyst 6500 series)


Supervisor Engine 2 Images

Image Filename and Size in Bytes
Description, Product ID, and Platform
(Installed; append "=" for spare on shippable media.)

Supports OSM, FlexWAN, SSHv2, and 3DES:
c6k222-pk9sv-mz.122-17d.SXB11a (36,201,004)
c6k222-pk9sv-mz.122-17d.SXB11 (36,192,332)
c6k222-pk9sv-mz.122-17d.SXB10 (36,199,852)
c6k222-pk9sv-mz.122-17d.SXB9  (36,183,184)
c6k222-pk9sv-mz.122-17d.SXB8  (36,158,288)
c6k222-pk9sv-mz.122-17d.SXB7 (deferred)
c6k222-pk9sv-mz.122-17d.SXB6 (deferred)
c6k222-pk9sv-mz.122-17d.SXB5 (deferred)
c6k222-pk9sv-mz.122-17d.SXB4 (deferred)
c6k222-pk9sv-mz.122-17d.SXB3 (deferred)
c6k222-pk9sv-mz.122-17d.SXB2 (deferred)
c6k222-pk9sv-mz.122-17d.SXB1 (deferred)
c6k222-pk9sv-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

IP W/SSH/3DES:
S222ZK9-12217SXB (Catalyst 6500 series)
S762ZK9-12217SXB (Cisco 7600 series)

Supports SSHv2 and 3DES:
c6k222-pk9s-mz.122-17d.SXB11a (25,603,104)
c6k222-pk9s-mz.122-17d.SXB11 (25,593,288)
c6k222-pk9s-mz.122-17d.SXB10 (25,599,148)
c6k222-pk9s-mz.122-17d.SXB9  (25,584,404)
c6k222-pk9s-mz.122-17d.SXB8  (25,562,768)
c6k222-pk9s-mz.122-17d.SXB7 (deferred)
c6k222-pk9s-mz.122-17d.SXB6 (deferred)
c6k222-pk9s-mz.122-17d.SXB5 (deferred)
c6k222-pk9s-mz.122-17d.SXB4 (deferred)
c6k222-pk9s-mz.122-17d.SXB3 (deferred)
c6k222-pk9s-mz.122-17d.SXB2 (deferred)
c6k222-pk9s-mz.122-17d.SXB1 (deferred)
c6k222-pk9s-mz.122-17d.SXB  (deferred)

Note This is a limited-access strong encryption image.

IP W/SSH/3DES LAN ONLY:
S222ZLK9-12217SXB (Catalyst 6500 series)

Supports OSM and FlexWAN:
c6k222-psv-mz.122-17d.SXB11a (34,935,488)
c6k222-psv-mz.122-17d.SXB11 (34,924,732)
c6k222-psv-mz.122-17d.SXB10 (34,933,412)
c6k222-psv-mz.122-17d.SXB9  (34,914,412)
c6k222-psv-mz.122-17d.SXB8  (34,890,524)
c6k222-psv-mz.122-17d.SXB7 (deferred)
c6k222-psv-mz.122-17d.SXB5 (deferred)
c6k222-psv-mz.122-17d.SXB4 (deferred)
c6k222-psv-mz.122-17d.SXB3 (deferred)
c6k222-psv-mz.122-17d.SXB2 (deferred)
c6k222-psv-mz.122-17d.SXB1 (deferred)
c6k222-psv-mz.122-17d.SXB  (deferred)

IP:
S222Z-12217SXB (Catalyst 6500 series)
S762Z-12217SXB (Cisco 7600 series)


c6k222-ps-mz.122-17d.SXB11a (24,333,568)
c6k222-ps-mz.122-17d.SXB11 (24,322,684)
c6k222-ps-mz.122-17d.SXB9  (24,317,120)
c6k222-ps-mz.122-17d.SXB8  (24,292,916)
c6k222-ps-mz.122-17d.SXB7 (deferred)
c6k222-ps-mz.122-17d.SXB6 (deferred)
c6k222-ps-mz.122-17d.SXB5 (deferred)
c6k222-ps-mz.122-17d.SXB4 (deferred)
c6k222-ps-mz.122-17d.SXB3 (deferred)
c6k222-ps-mz.122-17d.SXB2 (deferred)
c6k222-ps-mz.122-17d.SXB1 (deferred)
c6k222-ps-mz.122-17d.SXB  (deferred)

IP LAN ONLY:
S222ZL-12217SXB (Catalyst 6500 series)


Feature Sets in Release 12.2(17b)SXA and Rebuilds (Deferred)

Release 12.2(17b)SXA and rebuilds are deferred.

Feature Sets in Release 12.2(17a)SX and Rebuilds (Deferred)

Release 12.2(17a)SX and rebuilds are deferred.

Feature Sets in Release 12.2(14)SX and Rebuilds (Deferred)

Release 12.2(14)SX and rebuilds are deferred.

New Features


Note See the "Feature Sets" section for information about which releases are deferred.


New Features in Release 12.2(18)SXF5

New Features in Release 12.2(18)SXF4

New Features in Release 12.2(18)SXF3

New Features in Release 12.2(18)SXF2

New Features in Release 12.2(18)SXF1

New Features in Release 12.2(18)SXF

New Features in Release 12.2(18)SXE6

New Features in Release 12.2(18)SXE5

New Features in Release 12.2(18)SXE4

New Features in Release 12.2(18)SXE3

New Features in Release 12.2(18)SXE2

New Features in Release 12.2(18)SXE1

New Features in Release 12.2(18)SXE

New Features in Release 12.2(18)SXD7

New Features in Release 12.2(18)SXD6

New Features in Release 12.2(18)SXD5

New Features in Release 12.2(18)SXD4

New Features in Release 12.2(18)SXD3

New Features in Release 12.2(18)SXD2

New Features in Release 12.2(18)SXD1

New Features in Release 12.2(18)SXD

New Features in Release 12.2(17d)SXB11a

New Features in Release 12.2(17d)SXB11

New Features in Release 12.2(17d)SXB10

New Features in Release 12.2(17d)SXB9

New Features in Release 12.2(17d)SXB9

New Features in Release 12.2(17d)SXB7

New Features in Release 12.2(17d)SXB6

New Features in Release 12.2(17d)SXB5

New Features in Release 12.2(17d)SXB4

New Features in Release 12.2(17d)SXB3

New Features in Release 12.2(17d)SXB2

New Features in Release 12.2(17d)SXB1

New Features in Release 12.2(17d)SXB

New Features in Release 12.2(17b)SXA2

New Features in Release 12.2(17b)SXA

New Features in Release 12.2(17a)SX4

New Features in Release 12.2(17a)SX3

New Features in Release 12.2(17a)SX2

New Features in Release 12.2(17a)SX1

New Features in Release 12.2(17a)SX

New Features in Release 12.2(14)SX1

New Features in Release 12.2(14)SX

Software Features from Earlier Releases


NoteSee the following site for information about MIBs:

http://www.cisco.com/public/sw-center/netmgmt/cmtk/mibs.shtml

Features in the Cisco IOS 12.2SX releases that are also supported in the Cisco IOS 12.2 mainline, 12.2T and 12.2S releases are documented in the publications for these releases. When applicable, this section refers to these publications for platform-independent features supported in the Cisco IOS 12.2SX releases.


New Features in Release 12.2(18)SXF5

These sections describe the new features in Release 12.2(18)SXF5, 10 Jul 2006:

New Hardware Features in Release 12.2(18)SXF5

New Software Features in Release 12.2(18)SXF5

New Hardware Features in Release 12.2(18)SXF5

8-port 10-Gigabit Ethernet X2switching module ( WS-X6708-10GE)

Multi-Processor WAN Application Module (MWAM) support with Supervisor Engine 32:

WS-SVC-MWAM-1

Also supported with Supervisor Engine 720

Also supported with Supervisor Engine 2

See these publications for more information:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/servmod/esa_mwam.htm

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/mwam/index.htm

New Software Features in Release 12.2(18)SXF5

Autostate - Firewall Capability for the Firewall service module—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/fwsm/index.htm

With Cisco IOS software modularity images:

Support for Supervisor Engine 32

Multi-VRF (VRF Lite)

With Cisco IOS software images, Embedded Event Manager (EEM) 2.1 (previously supported with Cisco IOS software modularity images)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx
/122sxf18/evnt_mgr/index.htm

DSCP-based Queue Mapping—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/qos.htm

IGMP Static Group Range Support—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/
122sxf18/stgrpsxf.htm

QoS - Ignore Port Trust—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/qos.htm

RSVP Interface-based Receiver Proxy—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/
122sxf18/rsvpprox.htm

RSVP Refresh Reduction and Reliable Messaging—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120limit/120s/120s29/fsrelmsg.htm

RSVP Scalability Enhancements—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122t/122t2/rsvpscal.htm

SRR (Shaped Round Robin)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/qos.htm

WCCP L2 Return—With Supervisor Engine 2, you can configure WCCP to use the Layer 2 return WCCP feature.

New Features in Release 12.2(18)SXF4

These sections describe the new features in Release 12.2(18)SXF4, 27 Mar 2006:

New Hardware Features in Release 12.2(18)SXF4

New Software Features in Release 12.2(18)SXF4

New Hardware Features in Release 12.2(18)SXF4

Application Control Engine (ACE) module ( ACE10-6500-K9)

New Software Features in Release 12.2(18)SXF4

IPS Inline VLAN Pairing for WS-SVC-IDSM2-K9—See this publication for more information:

http://www.cisco.com/univercd/cc/td/doc/product/iaabu/csids/csids12/cliguide/index.htm

Cisco IOS Software Modularity support with Supervisor Engine 720—See these sections for information about Cisco IOS Software Modularity:

Cisco IOS Software Modularity Images

Cisco IOS Software Modularity Documentation

Cisco IOS Software Modularity Unsupported Features

New Features in Release 12.2(18)SXF3

These sections describe the new features in Release 12.2(18)SXF3, 16 Feb 2006:

New Hardware Features in Release 12.2(18)SXF3

New Software Features in Release 12.2(18)SXF3

New Hardware Features in Release 12.2(18)SXF3

96-port 10/100TX RJ-45 switching module ( WS-X6148X2-RJ-45, WS-X6148X2-45AF)

96-port 10/100TX RJ-21 switching module ( WS-X6196-RJ-21, WS-X6196-21AF)

IEEE 802.3af PoE daughtercard for WS-X6148X2-RJ-45 and WS-X6196-RJ-21 (WS-F6K-FE48X2-AF)

New Software Features in Release 12.2(18)SXF3

None.

New Features in Release 12.2(18)SXF2

These sections describe the new features in Release 12.2(18)SXF2, 20 Jan 2006:

New Hardware Features in Release 12.2(18)SXF2

New Software Features in Release 12.2(18)SXF2

New Hardware Features in Release 12.2(18)SXF2

Wireless Services Module (WiSM; WS-SVC-WISM-1-K9)

1-port OC-192c/STM-64 POS/RPR SPA, VSR-1 ( SPA-OC192POS-VSR):

Supported only with 7600-SIP-600

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

100BASE SFPs for use with WS-X6148-FE-SFP:

100BASE-BX10-U SFP ( GLC-FE-100BX-U)

100BASE-BX10-D SFP ( GLC-FE-100BX-D)

Support with Supervisor Engine 32 for these modules:

Services SPA Carrier (SSC; 7600-SSC-400)


Note 7600-SSC-400 does not maintain state when an NSF with SSO redundancy mode switchover occurs.


IPsec SPA ( SPA-IPSEC-2G)

Also supported with Supervisor Engine 720

SPA-IPSEC-2G supports the features that were previously supported with WS-SVC-IPSEC-1.

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Support with Supervisor Engine 2 for these modules:

48-port 10/100TX RJ-45 switching module ( WS-X6148A-RJ-45, WS-X6148A-45AF)

48-port 10/100/1000 Mbps switching module ( WS-X6148A-GE-TX, WS-X6148A-GE-45AF)

48-port 100BASE-FX switching module ( WS-X6148-FE-SFP), with these SFPs:

100BASE-BX10-U SFP ( GLC-FE-100BX-U)

100BASE-BX10-D SFP ( GLC-FE-100BX-D)

100BASEEX SFP ( GLC-FE-100EX)

100BASEZX SFP ( GLC-FE-100ZX)

100BASEFX SFP ( GLC-FE-100FX)

100BASELX SFP ( GLC-FE-100LX)

Fast Ethernet port adapters ( PA-2FE, PA-1FE)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/index.htm

1-port Packet over SONET OC3c/STM1 port adapter ( PA-POS-1OC3)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/7301/73pa/73-son/6514_1oc/index.htm

Receive-only coarse or dense Wavelength Division Multiplexing (WDM) GBIC ( WDM-GBIC-REC)

New Software Features in Release 12.2(18)SXF2

NAC - L2 IP; Network Admission Control (NAC) Layer 2 Layer 2 IP validation (not supported with Supervisor Engine 2)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/nac.htm

Encrypted Multicast over GRE (supported on SPA-IPSEC-2G)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Control Plane DSCP Support for RSVP—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122t/122t2/dscprsvp.htm

RSVP Scalability Enhancements—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122t/122t2/rsvpscal.htm

Dot1q Transparency for EoMPLS on WAN ports—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/mpls.htm

RFC 1483 Spanning-Tree Interoperability Enhancements on WAN ports—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/atm.htm

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/features.htm

Support with Supervisor Engine 32 for:

NetFlow v9 Export Format, including NetFlow Export of BGP Nexthop Information

NetFlow multicast support

PIM snooping DR flooding enhancement

Support with Supervisor Engine 2 for these features, which are already supported with other Supervisor Engines:

Any transport over MPLS (AToM): HDLC over MPLS (HDLCoMPLS)

Any transport over MPLS (AToM): PPP over MPLS (PPPoMPLS)

ATM OAM ping

ATM VC access trunk emulation

Bandwidth command for HQoS parent class support

BGP multipath load sharing for both eBGP and iBGP in an MPLS-VPN

BGP support for TTL security check

Bidirectional forwarding detection (BFD) standard implementation

Bridge control protocol (BCP)

Bridging using RFC1483 routed encapsulation (BRE)

Clear hardware interface counters

CNS interactive CLI

Configurable per VLAN MAC learning (PVL)

CSG: content services gateway release 6

DE/CLP and EXP mapping on FR/ATMoMPLS VC

Digital optical monitoring (DOM)

Distributed MLPPP (dMLPPP) on FlexWAN module interfaces

Dynamic multipoint VPN (DMVPN) phase 2

EIGRP MPLS VPN PE-CE Site of Origin (SoO)

Embedded network management improvements

EtherChannel enhancement - 128 EtherChannels support

EtherChannel Min-Links

Ethernet over MPLS (EoMPLS) per VLAN QoS

Flex Links

Frame Relay Virtual Circuit (VC) bundling

Hardware capacity monitoring

HQoS support for Ethernet over MPLS (EoMPLS) VC

H-VPLS with MPLS edge

IDSM-2 EtherChannel load balancing

IEEE 802.1s - Multiple Spanning Tree (MST) standard compliance

Integrated IS-IS global default metric

Integrated IS-IS protocol shutdown support maintaining configuration parameters

Integrated IS-IS support for BFD over IPv4

Invalid Special Parameter Index (SPI) recovery

IP routing of RFC1483 ATM Bridge Encapsulation (RBE)

IP unnumbered for VLAN-SVI interfaces

IS-IS caching of redistributed routes

IS-IS support for priority-driven IP prefix RIB installation

Key rollover for certificate renewal

Layer 2 traceroute

MPLS LDP - inbound label binding filtering

MPLS LSP ping/traceroute and AToM VCCV

MQC: distribution of remaining bandwidth

Multicast-VPN: multicast support for MPLS VPN

Multipoint Bridging (MPB)

NetFlow - bridged flow statistics

OSPF link state database overload protection

OSPF Link-Local Signaling (LLS) per interface basis

OSPF MIB support of RFC 1850 and latest extensions

OSPF support for BFD over IPv4

OSPF support for forwarding adjacencies over MPLS traffic engineered tunnels

OSPF support for unlimited software VRFs per Provider Edge (PE) router

Packet classification based on layer3 packet-length (supported on WAN ports)

Per interface sticky ARP

Per port MAC limiting

Per VLAN load balancing for advanced QinQ service mapping

PIM snooping DR flooding enhancement

PKI AAA authorization using the entire subject name

Port security on 802.1Q tunnel ports

Port security on private VLAN ports

Port security on trunk ports

Port security with 4096 secure MAC addresses

Port security with sticky MAC addresses

Protected private key storage

QoS: aggregated DSCP / precedence values for WRED

QoS: ingress shaping on FlexWAN module interfaces

QoS: match VLAN on OSMs

QoS: percentage based policing on WAN ports

Query mode definition per trustpoint

Query multiple servers during certificate revocation check

RADIUS Load Balancing (RLB) IMSI sticky

Re-enroll using existing certificate

RFC-1490 bridging on FlexWAN interfaces

SafeNet IPsec VPN client support

SCP health monitoring for enhanced-FlexWAN

Show diagnostic sanity

Show Top-N

SLB: interface-aware

SLB: stateful failover within single chassis

SPAN destination port permit list

Strict priority low latency queueing (LLQ)

Sub interface features - phase 1

Unicast flood blocking (UFB)

Uni-Directional Link Routing (UDLR)

verify certificate chain command

VLANs over IP unnumbered sub-interfaces

New Features in Release 12.2(18)SXF1

These sections describe the new features in Release 12.2(18)SXF1, 22 Dec 2005:

New Hardware Features in Release 12.2(18)SXF1

New Software Features in Release 12.2(18)SXF1

New Hardware Features in Release 12.2(18)SXF1

None.

New Software Features in Release 12.2(18)SXF1

DHCP Option 82 on Untrusted Port—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/snoodhcp.htm

New Features in Release 12.2(18)SXF

These sections describe the new features in Release 12.2(18)SXF, 12 Sep 2005:

New Hardware Features in Release 12.2(18)SXF

New Software Features in Release 12.2(18)SXF

New Hardware Features in Release 12.2(18)SXF


Note Initial support for these modules is now in Release 12.2(18)SXF3:

96-port 10/100TX RJ-45 switching module ( WS-X6148X2-RJ-45, WS-X6148X2-45AF)

96-port 10/100TX RJ-21 switching module ( WS-X6196-RJ-21, WS-X6196-21AF)

IEEE 802.3af PoE daughtercard for WS-X6148X2-RJ-45 and WS-X6196-RJ-21 (WS-F6K-FE48X2-AF)

(CSCsd16853)


Compact Flash Adapter in Bootflash Slot (WS-CF-UPG=):

CompactFlash adapter with 512 MB CompactFlash card that replaces the bootflash device.

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_17277.htm

Supervisor Engine 32 ( WS-SUP32-10GE-3B, WS-SUP32-GE-3B)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/6000hw/supe_gd/index.htm


Note See the "Supervisor Engine 32 (CAT6000-SUP32/MSFC2A, 7600-SUP32/MSFC2A)" section for the list of features not supported with Supervisor Engine 32.


48-port 10/100/1000 Mbps switching module ( WS-X6148A-GE-TX, WS-X6148A-GE-45AF)

48-port 100BASE-FX switching module ( WS-X6148-FE-SFP), with these SFPs:

100BASEFX SFP ( GLC-FE-100FX)

100BASELX SFP ( GLC-FE-100LX)

48-port 10/100TX RJ-45 switching module ( WS-X6148A-RJ-45, WS-X6148A-45AF)

SPA Interface Processor-600 ( 7600-SIP-600)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

1-port 10-Gigabit Ethernet SPA, LANPHY XFP Optics ( SPA-1XTENGE-XFP), with this XFP module: 10-Gigabit Ethernet LR (10 km; XFP-10GLR-OC192LR)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

10-port Gigabit Ethernet SPA, SFP Optics ( SPA-10X1GE)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

5-port Gigabit Ethernet SPA, SFP Optics ( SPA-5X1GE)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

2-port Gigabit Ethernet SPA, SFP Optics ( SPA-2X1GE), with these SFPs:

Extended Temperature SX SFP ( SFP-GE-S)

Extended Temperature LX/LH SFP ( SFP-GE-L)

Extended Temperature ZX SFP ( SFP-GE-Z)

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

1-port OC-192c/STM-64 POS/RPR SPA, SM-LR ( SPA-OC192POS-LR)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

1-port OC-192c/STM-64 POS/RPR SPA, XFP Optics ( SPA-OC192POS-XFP), with these XFP modules:

Single-Mode (SM) Short Reach (SR; XFP-10GLR-OC192SR)

Single-Mode (SM) Intermediate Reach (IR-2; XFP-10GER-OC192IR)

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

1 port OC-48c/STM-16 ATM SPA ( SPA-1XOC48-ATM)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Firewall Services module support with Supervisor Engine 32:

WS-SVC-FWM-1-K9

Also supported with Supervisor Engine 720.

Also supported with Supervisor Engine 2.

See this publication for more information:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/mod_icn/fwsm/index.htm

Network Analysis Module support with Supervisor Engine 32:

WS-SVC-NAM-1 and WS-SVC-NAM-2

Also supported with Supervisor Engine 720

Also supported with Supervisor Engine 2

See this publication for more information:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/78_15353.htm

Intrusion Detection System Module 2 support with Supervisor Engine 32:

WS-SVC-IDSM2-K9

Also supported with Supervisor Engine 720

Also supported with Supervisor Engine 2

See this publication for more information:

http://www.cisco.com/univercd/cc/td/doc/product/iaabu/csids/csids10/4029_02.htm

Secure Sockets Layer (SSL) Services Module support with Supervisor Engine 32:

WS-SVC-SSL-1

Also supported with Supervisor Engine 720

Also supported with Supervisor Engine 2

See this publication for more information:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/ol_5277.htm

New Software Features in Release 12.2(18)SXF


Note See the "Supervisor Engine 32 (CAT6000-SUP32/MSFC2A, 7600-SUP32/MSFC2A)" section for the list of features not supported with Supervisor Engine 32.


H-VPLS with MPLS Edge—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/mpls.htm

'match cos' classification on 7600-SIP-400—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

EtherChannel Min-Links—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/channel.htm

Flex Links—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/flexlink.htm

Hardware Capacity Monitoring—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/pwr_envr.htm

IEEE 802.1s - Multiple Spanning Tree (MST) Standard Compliance—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/mst.htm

IP Unnumbered for VLAN-SVI interfaces—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/layer3.htm

L3 MPLS VPN over GRE (7600-SIP-400)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Mapping a subinterface to an EoMPLS VC (7600-SIP-400)——See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Multicast enhancement - egress replication performance improvement—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/mcastv4.htm

Multicast Enhancement - Replication Mode Detection—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/mcastv4.htm

NetFlow v9 Export Format, including NetFlow Export of BGP Nexthop Information—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123_1/nfv9expf.htm

NetFlow multicast support:

Supported only with NetFlow v9 export format.

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123_1/nfmultic.htm

The NetFlow Multicast Support document contains a prerequisite that does not apply when configuring NetFlow multicast support with Release 12.2(18)SXF and later 12.2SX releases:

You do not need to configure multicast fast switching or multicast distributed fast switching (MDFS); multicast CEF switching is supported with Release 12.2(18)SXF and later 12.2SX releases.

Per Interface Sticky ARP—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/dos.htm

PIM snooping DR flooding enhancement—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/snooppim.htm

New Features in Release 12.2(18)SXE6

These sections describe the new features in Release 12.2(18)SXE6, 08 Jun 2006:

New Hardware Features in Release 12.2(18)SXE6

New Software Features in Release 12.2(18)SXE6

New Hardware Features in Release 12.2(18)SXE6

None.

New Software Features in Release 12.2(18)SXE6

None.

New Features in Release 12.2(18)SXE5

These sections describe the new features in Release 12.2(18)SXE5, 13 Feb 2006:

New Hardware Features in Release 12.2(18)SXE5

New Software Features in Release 12.2(18)SXE5

New Hardware Features in Release 12.2(18)SXE5

Compact Flash Adapter in Bootflash Slot (WS-CF-UPG=):

CompactFlash adapter with 512 MB CompactFlash card that replaces the bootflash device.

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/cfgnotes/78_17277.htm

New Software Features in Release 12.2(18)SXE5

UDI - Unique Device Identifier—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_4/gtpepudi.htm

New Features in Release 12.2(18)SXE4

These sections describe the new features in Release 12.2(18)SXE4, 10 Oct 2005:

New Hardware Features in Release 12.2(18)SXE4

New Software Features in Release 12.2(18)SXE4

New Hardware Features in Release 12.2(18)SXE4

None.

New Software Features in Release 12.2(18)SXE4

None.

New Features in Release 12.2(18)SXE3

These sections describe the new features in Release 12.2(18)SXE3, 22 Aug 2005:

New Hardware Features in Release 12.2(18)SXE3

New Software Features in Release 12.2(18)SXE3

New Hardware Features in Release 12.2(18)SXE3

None.

New Software Features in Release 12.2(18)SXE3

None.

New Features in Release 12.2(18)SXE2

These sections describe the new features in Release 12.2(18)SXE2, 23 Jun 2005:

New Hardware Features in Release 12.2(18)SXE2

New Software Features in Release 12.2(18)SXE2

New Hardware Features in Release 12.2(18)SXE2

Support with Supervisor Engine 720 for these modules:

Services SPA Carrier (SSC; 7600-SSC-400)


Note 7600-SSC-400 does not maintain state when an NSF with SSO redundancy mode switchover occurs.


IPsec SPA ( SPA-IPSEC-2G):

Also supported with Supervisor Engine 32

SPA-IPSEC-2G supports the features that were previously supported with WS-SVC-IPSEC-1.

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

New Software Features in Release 12.2(18)SXE2

None.

New Features in Release 12.2(18)SXE1

These sections describe the new features in Release 12.2(18)SXE1, 18 Apr 2005:

New Hardware Features in Release 12.2(18)SXE1

New Software Features in Release 12.2(18)SXE1

New Hardware Features in Release 12.2(18)SXE1

Application-Oriented Networking (AON) Module ( WS-SVC-AON-1-K9) support with Supervisor Engine 720—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/aon/index.htm

WebVPN Services Module ( WS-SVC-WEBVPN-K9; not supported with Supervisor Engine 2)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/ol_7761.htm

New Software Features in Release 12.2(18)SXE1

None.

New Features in Release 12.2(18)SXE

These sections describe the new features in Release 12.2(18)SXE, 11 Apr 2005:

New Hardware Features in Release 12.2(18)SXE

New Software Features in Release 12.2(18)SXE

New Hardware Features in Release 12.2(18)SXE

Anomaly Guard Module ( WS-SVC-AGM-1-K9)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/secure/ad_g/jaffa/jaffaagd.htm

Traffic Anomaly Detector Module ( WS-SVC-ADM-1-K9)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/secure/ad_g/jaffa/jaffatad.htm

2700 W AC power supply for CISCO7606 chassis ( PWR-2700-AC)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/hardware/cis_76xx/index.htm

2700 W DC power supply for CISCO7606 chassis ( PWR-2700-DC)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/hardware/cis_76xx/index.htm

2700 W DC power supply for 4-slot chassis ( PWR-2700-DC/4)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/hardware/cis_76xx/index.htm

Catalyst 6500 series switch 4-slot chassis ( WS-C6504-E)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/6000hw/6500_ins/index.htm

Cisco 7600 series router 4-slot chassis ( CISCO7604)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/hardware/cis_76xx/index.htm

Cisco 7600 Series SPA Interface Processor-200 ( 7600-SIP-200)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Cisco 7600 Series SPA Interface Processor-400 ( 7600-SIP-400)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Cisco 1-Port OC-12c/STM-4c ATM Shared Port Adapter ( SPA-1XOC12-ATM)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Cisco 1-Port OC-12c/STM-4c POS Shared Port Adapter ( SPA-1XOC12-POS)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Cisco 8-Port Channelized T1/E1 Shared Port Adapter ( SPA-8XCHT1/E1)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Cisco Channelized T3 to DS0 Shared Port Adapter ( SPA-2XCT3/DS0, SPA-4XCT3/DS0)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Cisco Clear Channel T3/E3 Shared Port Adapter ( SPA-2XT3/E3, SPA-4XT3/E3)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Cisco OC-3c/STM-1c ATM Shared Port Adapter ( SPA-2XOC3-ATM, SPA-4XOC3-ATM)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Cisco OC-3c/STM-1c POS Shared Port Adapter ( SPA-2XOC3-POS, SPA-4XOC3-POS)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/76sipspa/index.htm

Fast Ethernet port adapters ( PA-2FE, PA-1FE)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/index.htm

1-port Packet over SONET OC3c/STM1 port adapter ( PA-POS-1OC3)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/7301/73pa/73-son/6514_1oc/index.htm

Content Switching Module with SSL (CSM-S; WS-X6066-SLB-S-K9)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/78_16597.htm

10GBASE-LW XENPAK Module with WAN PHY for SMF ( XENPAK-10GB-LW)

10GBASE dense wavelength-division multiplexing (DWDM) 100-GHz ITU grid ( DWDM-XENPAK)

10GBASE receive-only wavelength division multiplexing (WDM; WDM-XENPAK-REC)

1000BASE-BX10 SFP module for single-strand SMF, 1490-nm TX/1310-nm RX wavelength ( GLC-BX-D)

1000BASE-BX10 SFP module for single-strand SMF, 1310-nm TX/1490-nm RX wavelength ( GLC-BX-U)

Receive-only coarse or dense Wavelength Division Multiplexing (WDM) GBIC ( WDM-GBIC-REC)

New Software Features in Release 12.2(18)SXE

Any Transport over MPLS (AToM): HDLC over MPLS (HDLCoMPLS):

Supported on WAN ports.

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/index.htm

Any Transport over MPLS (AToM): PPP over MPLS (PPPoMPLS):

Supported on WAN ports.

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/index.htm

ATM VC access trunk emulation—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/index.htm

BGP multipath load sharing for both eBGP and iBGP in an MPLS-VPN—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/12218sxe/fsxeibmp.htm


Note With the BGP multipath load sharing for both eBGP and iBGP in an MPLS-VPN feature configured, do not attach output service policies to VRF interfaces. (CSCsb25509)

For nonMPLS environments, see the Interior Border Gateway Protocol (iBGP) Multipath Load Sharing feature.


BGP support for TTL security check—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/12218sxe/fsxebtsh.htm

Bidirectional Forwarding Detection (BFD) standard implementation—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/12218sxe/fs_bfd.htm


Note Catalyst 6500 switches and Cisco 7600 routers support BFD only on Ethernet, Fast Ethernet (except PA-2FE and PA-1FE), Gigabit Ethernet, Gigabit Ethernet WAN (GE-WAN), and 10-Gigabit Ethernet ports, including Ethernet SPAs. The Catalyst 6500 switches and Cisco 7600 routers do not support BFD on PA-2FE or PA-1FE Ethernet LAN ports, or on POS, ATM, or serial WAN ports.

Also see " Integrated IS-IS support for BFD over IPv4" and " OSPF support for BFD over IPv4."


Bridge Control Protocol (BCP)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/features.htm

Bridging using RFC1483 Routed Encapsulation (BRE)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/index.htm

Clear hardware interface counters—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/cmdref/index.htm

CNS Interactive CLI—Network management applications can use the Cisco Networking Services (CNS) agents to manage network routers. The CNS agent provides the capability to send commands to a router from a programmable source. The CNS Interactive CLI feature introduces a new XML interface that allows you to send interactive commands to a router, such as commands that generate prompts for user input. A benefit of this feature is that interactive commands can be aborted before they have been fully processed. For example, for commands that generate a significant amount of output, the XML interface can be customized to limit the size of the output or the length of time allowed for the output to accumulate. The capability to use a programmable interface to abort a command before its normal termination (similar to manually aborting a command) can greatly increase the efficiency of diagnostic applications that might use this functionality. The new XML interface also allows for multiple commands to be processed in a single session. The response for each command is packaged together and sent in a single response event.

Configurable Per VLAN MAC Learning (PVL)—See the mac-address-table learning command in this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/cmdref/index.htm

CSG: Content Services Gateway Release 6—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/wireless/moblwrls/csg/index.htm

DE/CLP and EXP mapping on FR/ATMoMPLS VC—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/mpls.htm

DHCP Snooping (supported only with PFC3)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/snoodhcp.htm

Digital Optical Monitoring (DOM)—See the show interfaces transceiver command in this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/cmdref/index.htm


Note See this publication for additional information about DOM:

http://www.cisco.com/univercd/cc/td/doc/product/gbic_sfp/gbic_doc/ol_8031.htm


Dynamic ARP Inspection (DAI; supported only with PFC3)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/dynarp.htm

Dynamic Multipoint VPN (DMVPN) Phase 2

In Release 12.2(18)SXE2 and later releases, supported with SPA-IPSEC-2G.

In Release 12.2(18)SXE and later releases, supported with WS-SVC-IPSEC-1.

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122t/122t13/ftgreips.htm

Egress ACL support for remarked DSCP (supported only with PFC3)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/qos.htm

EIGRP MPLS VPN PE-CE site of origin (SoO)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120limit/120s/120s27/s_mvesoo.htm

Embedded network management improvements—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/7600mibs/index.htm

Encapsulated Remote SPAN (ERSPAN)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/span.htm

EtherChannel Enhancement - 128 EtherChannels Support—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/channel.htm

Ethernet over MPLS (EoMPLS) per VLAN QoS—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/mpls.htm

Field-programmable device upgrade tool—The Cisco SPA field-programmable device (FPD) upgrade tool provides customers and field engineers a consistent way across platforms to upgrade firmware or images for the programmable devices (for example, FPGAs, PLDs, ROMMON). The customer can get proper images from Cisco.com, and use this tool to automatically download (with a flash card or TFTP) to the FPD tool, or manually if needed. The FPD tool provides a convenient and safe way for customer to upgrade an FPD for related bug fixes and feature enhancement with minimum system impact. The FPD tool significantly improves customer satisfaction and product reliability.

Frame Relay virtual circuit (VC) bundling—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/index.htm

HQoS support for Ethernet over MPLS (EoMPLS) VC—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/index.htm

IDSM-2 EtherChannel load balancing—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/iaabu/csids/csids11/cliguide/index.htm

Integrated IS-IS global default metric—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_4/gtisglob.htm

Integrated IS-IS protocol shutdown support maintaining configuration parameters—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_4/gtisprot.htm

Integrated IS-IS support for BFD over IPv4—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/12218sxe/fs_bfd.htm


Note Also see " Bidirectional Forwarding Detection (BFD) standard implementation."


Invalid Special Parameter Index (SPI) Recovery—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_2/gt_ispir.htm

IP routing of RFC1483 ATM bridge encapsulation (RBE)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/index.htm

PFC3 hardware support for IPv4 multicast over point-to-point GRE tunnels—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122cgcr/finter_c/icflogin.htm


Note Releases earlier than Release 12.2(18)SXE supported IPv4 multicast over point-to-point GRE tunnels in software on the MSFC. The PFC3 does not provide hardware acceleration for tunnels configured with the tunnel key command.


IPv6 access services: DHCPv6 prefix delegation—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122t/122t13/ipv6_vgf.htm

IPv6 hardware: multicast assist—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/mcastv6.htm

IPv6 multicast RPR/RPR+ support—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/redund.htm

IPv6 multicast: Bootstrap Router (BSR)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123cgcr/ipv6_c/sa_mcast.htm

IPv6 Multicast: HW assisted egress replication—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/mcastv6.htm

IPv6 QoS: (quality of service)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/qos.htm

IS-IS caching of redistributed routes—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120limit/120s/120s27/isredrib.htm

IS-IS support for priority-driven IP prefix RIB installation—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120limit/120s/120s26/fslocrib.htm

Key rollover for certificate renewal—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_7/gtkyroll.htm

Lawful Intercept with CSG Module (CSG-LI; WS-SVC-CSG-1) on Supervisor Engine 720:

Also supported on Supervisor Engine 2.

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/wireless/moblwrls/csg/csgr4/csgrnl4.htm

Layer 2 traceroute—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/l2trace.htm

MLD snooping—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/snoopmld.htm

MPLS LDP - Inbound Label Binding Filtering—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122s/122snwft/release/122s25/fsinbd4.htm

MPLS LSP ping/traceroute and AToM VCCV—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/12218sxe/sx_lsppt.htm

MQC: distribution of remaining bandwidth (supported only on WAN ports)—You configure QoS features on an interface using the modular QoS CLI (MQC). Using MQC, you create service policies for traffic classes and attach the policies to an interface. You can use MQC to specify how the remaining bandwidth is distributed among the interface or subinterface output queues. The remaining bandwidth is the available bandwidth left on an interface or subinterface after all guaranteed traffic is accounted for. The amount of remaining bandwidth available for use is determined by the excess information rate (EIR) configured for the queue.

The bandwidth remaining percent command allows you to configure the remaining bandwidth for output queues. The aggregate of all user-configured EIR bandwidth percentages cannot exceed 100 percent. If the aggregate of all remaining bandwidth is less than 100 percent, the remainder is evenly split among user queues (including the default queue) that do not have a remaining bandwidth percentage configured. The minimum EIR value of each output queue is 1.

This example shows how to use the bandwidth remaining percent command to distribute percentages of remaining bandwidth to various traffic classes in a policy map:

Router# configure terminal 
Enter configuration commands, one per line.  End with CNTL/Z. 
Router(config)# policy-map myPolicy 
Router(config-pmap)# class class-default 
Router(config-pmap-c)# bandwidth remaining percent 20 
Router(config-pmap-c)# class prec1 
Router(config-pmap-c)# bandwidth remaining percent 30 
Router(config-pmap-c)# class prec2 
Router(config-pmap-c)# bandwidth remaining percent 10 
Router(config-pmap-c)# bandwidth percent 50 
Router(config-pmap-c)# end 
Router# show policy-map myPolicy 
  Policy Map myPolicy 
    Class prec1 
         bandwidth remaining percent 30 
    Class prec2 
         bandwidth percent 50 
         bandwidth remaining percent 10 
    Class class-default 
         bandwidth remaining percent 20 
Router#

Multicast-VPN: Multicast Support for MPLS VPN—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/mvpn.htm


Note Support for MVPN also includes support for multicast VRF (MVRF). MVRF is also known as multicast over VRF-lite. MVPN and MVRF are supported in PFC3B or PDC3BXL mode.


Multipoint bridging (MPB)—See these publications:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/features.htm

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/pos.htm

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/atm.htm

NetFlow - Bridged Flow Statistics—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/nde.htm

Netflow Multiple Export Destinations:

In Release 12.2(18)SXF and later releases, supported with Supervisor Engine 32

In Release 12.2(18)SXE and later releases, supported with Supervisor Engine 720

In Release 12.2(18)SXD and later releases, supported with Supervisor Engine 2

Allows entry of a second ip flow-export destination command

See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/nde.htm

OSPF link state database overload protection—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120limit/120s/120s27/ospfopro.htm

OSPF link-local signaling (LLS) per interface basis—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120limit/120s/120s27/ospflls.htm

OSPF MIB support of RFC 1850 and latest extensions—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/7600mibs/index.htm

OSPF support for BFD over IPv4—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122sx/12218sxe/fs_bfd.htm


Note Also see " Bidirectional Forwarding Detection (BFD) standard implementation."


OSPF support for forwarding adjacencies over MPLS traffic engineered tunnels—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120limit/120s/120s24/ospffa.htm

OSPF support for unlimited software VRFs per provider edge (PE) router—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_4/gtospfvf.htm

Packet classification based on layer3 packet-length (supported on WAN ports)—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122t/122t13/ftmchpkt.htm

Per port MAC limiting—See the mac-address-table limit command in this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/cmdref/index.htm

Per VLAN load balancing for advanced QinQ service mapping—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/index.htm

PKI AAA authorization using the entire subject name—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_11/gt_dnall.htm

Port security on 802.1Q tunnel ports, port security on private VLAN ports, port security on trunk ports, port security with 4096 secure MAC addresses, and port security with sticky MAC addresses—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/122sx/swcg/port_sec.htm

Protected private key storage—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_7/gt_ppkey.htm

QoS: Aggregated DSCP / Precedence Values for WRED—Aggregates multiple DSCP or IP Precedence values for a single minimum or maximum threshold and marks probability when specifying WRED parameters for 7600-SIP-400 ATM SPAs.

QoS: ingress shaping on FlexWAN module interfaces—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/flexport/combo/index.htm

QoS: match VLAN on OSMs—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/core/cis7600/cfgnotes/optical/122sx/index.htm

QoS: percentage based policing on WAN ports—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/120newft/120limit/120s/120s28/12spctpg.htm

Query mode definition per trustpoint—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_7/gt_qerym.htm

Query multiple servers during certificate revocation check—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios123/123newft/123t/123t_7/gtcertrc.htm

Re-enroll using existing certificate—See this publication:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122z/122zh13/gthttpca.htm